Accuracy of fit of 3-to-3 retainers after adhesive fixation using a neodymium-iron-boron magnet chain.

Wolfram Hahn1, Wiebke Wasser-Merkel, Katharina Lange, Rudolf M Gruber, Dietmar Kubein-Meesenburg, Dankmar Ihlow.   

Abstract

BACKGROUND AND
OBJECTIVE: Six-base retainers are often used to prevent tertiary crowding. To minimize shear stress on the retainer, these should be fitted as precisely as possible. The aim of this study was to compare the accuracy of fit of 6-base retainers after adhesive fixation using a neodymium-iron-boron (NdFeB) magnet chain or a resin positioning aid.
MATERIALS AND METHODS: A 6-base retainer was prepared for 40 pseudo-anonymous lower jaw models (2 × 20). Temporary fixation was performed with a resin positioning aid or a NdFeB magnet chain. The adhesive fixation of the retainers was randomized. The area and vertical distance between wire and teeth were determined by histomorphometry. The results were evaluated by ANOVA. The probability of error was specified as 5%.
RESULTS: With the magnetic chain method, the area was significantly smaller than with the positioning aid (p = 0.0125). The difference between the two methods was ca. 1.3 mm². Moreover, the measured distance was affected significantly by the method used (p < 0.0002). With the magnet chain, the distance between the tooth and retainer was reduced by a mean of 0.05 mm. Conclusion. The fit of the retainer wire improves somewhat when the NdFeB magnet chain is used even though the wire is not as precisely positioned as it would be with a custom-made positioning aid.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21975795     DOI: 10.1007/s00056-011-0042-3

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  25 in total

1.  An experimental method for in vivo analysis of biomechanical asymmetries of the periodontium.

Authors:  Dankmar Ihlow; Michael Cronau; Dietmar Kubein-Meesenburg; Gernot Heine; Henning Dathe; Claudia Hansen; Hans Nägerl
Journal:  J Orofac Orthop       Date:  2003-09       Impact factor: 1.938

Review 2.  Stability and relapse of dental arch alignment.

Authors:  R M Little
Journal:  Br J Orthod       Date:  1990-08

3.  The irregularity index: a quantitative score of mandibular anterior alignment.

Authors:  R M Little
Journal:  Am J Orthod       Date:  1975-11

4.  Biomechanical features of the periodontium: an experimental pilot study in vivo.

Authors:  Michael Cronau; Dankmar Ihlow; Dietmar Kubein-Meesenburg; Jochen Fanghänel; Henning Dathe; Hans Nägerl
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-05       Impact factor: 2.650

5.  Long-term experience with direct-bonded lingual retainers.

Authors:  E H Dahl; B U Zachrisson
Journal:  J Clin Orthod       Date:  1991-10

Review 6.  Principles of retention and avoidance of posttreatment relapse.

Authors:  K Reitan
Journal:  Am J Orthod       Date:  1969-06

Review 7.  The logic of modern retention procedures.

Authors:  H Kaplan
Journal:  Am J Orthod Dentofacial Orthop       Date:  1988-04       Impact factor: 2.650

8.  Potential interference of small neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators.

Authors:  Thomas Wolber; Salome Ryf; Christian Binggeli; Johannes Holzmeister; Corinna Brunckhorst; Roger Luechinger; Firat Duru
Journal:  Heart Rhythm       Date:  2006-09-16       Impact factor: 6.343

9.  The part played by the trans-septal fibre system in experimental approximal drift of the cheek teeth of monkeys (Macaca irus).

Authors:  D C Picton; J P Moss
Journal:  Arch Oral Biol       Date:  1973-06       Impact factor: 2.633

10.  The use of a neodymium-iron-boron magnet device for positioning a multi-stranded wire retainer in lingual retention--a pilot study in humans.

Authors:  Wolfram Hahn; Julia Fricke; Susanne Fricke-Zech; Antonia Zapf; Rudolf Gruber; Reza Sadat-Khonsari
Journal:  Eur J Orthod       Date:  2008-08-07       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.