Literature DB >> 21967948

Registration accuracy in the integration of laser-scanned dental images into maxillofacial cone-beam computed tomography images.

Hoon Noh1, Wael Nabha, Jin-Hyoung Cho, Hyeon-Shik Hwang.   

Abstract

INTRODUCTION: A precision 3-dimensional (3D) head model can be fabricated by integrating a digital dental model into a maxillofacial 3D image. The integration requires accurate registration of 2 image modalities. The aims of this study were to determine the registration errors for implementation of laser-scanned dental images into cone-beam computed tomography (CBCT) scan data and to examine the influence of the registration area on the accuracy of registration.
METHODS: The CBCT scans were obtained from 30 adults, and the maxillofacial 3D images were reconstructed. Maxillary and mandibular dental casts were taken from the same subjects and scanned with a 3D laser scanner. The laser-scanned maxillary and mandibular dentition images were incorporated into the CBCT images of each arch in 3 ways according to the registration area: only the buccal surfaces, only the lingual surfaces, and both the buccal and lingual surfaces. Surface-based registration was performed by using an iterative closest point algorithm, and its errors were evaluated by measuring the 3D Euclidean distances between the surface points on the 2 images.
RESULTS: The registration errors ranged from 0.27 to 0.33 mm. The mandibular arch did not show significant differences in registration errors according to the selected area for the registration. The maxillary arch, however, showed significant differences according to the registration area. When the lingual surfaces only were used for registration, the errors were greater than for the other 2 methods. The errors were least when both the buccal and lingual surfaces were used for registration.
CONCLUSIONS: The results of this study indicate that accuracy in the integration of laser-scanned dental images into the maxillofacial CBCT images increases when a broad area is used for registration.
Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Mesh:

Year:  2011        PMID: 21967948     DOI: 10.1016/j.ajodo.2011.04.018

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  14 in total

1.  A three-dimensional finite element analysis of the relationship between masticatory performance and skeletal malocclusion.

Authors:  Jung-Chul Park; Hyun-Seung Shin; Jung-Yul Cha; Jong-Tae Park
Journal:  J Periodontal Implant Sci       Date:  2015-02-25       Impact factor: 2.614

2.  Virtual facial reconstruction based on accurate registration and fusion of 3D facial and MSCT scans.

Authors:  Zhongwei Zhou; Peng Li; Jiayin Ren; Jixiang Guo; Yongqing Huang; Weidong Tian; Wei Tang
Journal:  J Orofac Orthop       Date:  2016-02-25       Impact factor: 1.938

3.  Effect of the presence of orthodontic brackets on intraoral scans.

Authors:  Sung-Ja Kang; Youn-Ju Kee; Kyungmin Clara Lee
Journal:  Angle Orthod       Date:  2021-01-01       Impact factor: 2.079

Review 4.  3D Printing and Virtual Surgical Planning in Oral and Maxillofacial Surgery.

Authors:  Adeeb Zoabi; Idan Redenski; Daniel Oren; Adi Kasem; Asaf Zigron; Shadi Daoud; Liad Moskovich; Fares Kablan; Samer Srouji
Journal:  J Clin Med       Date:  2022-04-24       Impact factor: 4.964

5.  Evaluation of different registration methods and dental restorations on the registration duration and accuracy of cone beam computed tomography data and intraoral scans: a retrospective clinical study.

Authors:  Xing-Yu Piao; Ji-Man Park; Hannah Kim; Youngjun Kim; June-Sung Shim
Journal:  Clin Oral Investig       Date:  2022-05-10       Impact factor: 3.606

6.  Comparison of cartilage and bone morphological models of the ankle joint derived from different medical imaging technologies.

Authors:  Gilda Durastanti; Alberto Leardini; Sorin Siegler; Stefano Durante; Alberto Bazzocchi; Claudio Belvedere
Journal:  Quant Imaging Med Surg       Date:  2019-08

7.  Integration of digital dental casts in cone-beam computed tomography scans.

Authors:  Frits A Rangel; Thomas J J Maal; Stefaan J Bergé; Anne Marie Kuijpers-Jagtman
Journal:  ISRN Dent       Date:  2012-09-23

8.  Vision-based markerless registration using stereo vision and an augmented reality surgical navigation system: a pilot study.

Authors:  Hideyuki Suenaga; Huy Hoang Tran; Hongen Liao; Ken Masamune; Takeyoshi Dohi; Kazuto Hoshi; Tsuyoshi Takato
Journal:  BMC Med Imaging       Date:  2015-11-02       Impact factor: 1.930

9.  Registration of the Cone Beam CT and Blue-Ray Scanned Dental Model Based on the Improved ICP Algorithm.

Authors:  Xue Mei; Zhenhua Li; Songsong Xu; Xiaoyan Guo
Journal:  Int J Biomed Imaging       Date:  2014-01-05

10.  Assessment of metal artifacts in three-dimensional dental surface models derived by cone-beam computed tomography.

Authors:  Wael Nabha; Young-Min Hong; Jin-Hyoung Cho; Hyeon-Shik Hwang
Journal:  Korean J Orthod       Date:  2014-09-25       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.