Direct impact analysis of multi-leaf collimator leaf position errors on dose distributions in volumetric modulated arc therapy: a pass rate calculation between measured planar doses with and without the position errors.

D Tatsumi1, M N Hosono, R Nakada, K Ishii, S Tsutsumi, M Inoue, T Ichida, Y Miki.   

Abstract

We propose a new method for analyzing the direct impact of multi-leaf collimator (MLC) leaf position errors on dose distributions in volumetric modulated arc therapy (VMAT). The technique makes use of the following processes. Systematic leaf position errors are generated by directly changing a leaf offset in a linac controller; dose distributions are measured by a two-dimensional diode array; pass rates of the dose difference between measured planar doses with and without the position errors are calculated as a function of the leaf position error. Three different treatment planning systems (TPSs) were employed to create VMAT plans for five prostate cancer cases and the pass rates were compared between the TPSs under various leaf position errors. The impact of the leaf position errors on dose distributions depended upon the final optimization result from each TPS, which was explained by the correlation between the dose error and the average leaf gap width. The presented method determines leaf position tolerances for VMAT delivery for each TPS, which may facilitate establishing a VMAT quality assurance program in a radiotherapy facility.

Entities:  

Mesh:

Year:  2011        PMID: 21965281     DOI: 10.1088/0031-9155/56/20/N03

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Dynamic positioning accuracy of a novel multileaf collimator for volumetric modulated arc therapy.

Authors:  Yuji Nakaguchi; Takeshi Ono; Ryota Onizuka; Masato Maruyama; Yoshinobu Shimohigashi; Yudai Kai
Journal:  Radiol Phys Technol       Date:  2015-11-26

2.  Minimum requirements for commissioning and long-term quality assurance of Elekta multi-leaf collimator for volumetric modulated arc therapy.

Authors:  Daisaku Tatsumi; Ryosei Nakada; Akane Yomoda; Kentaro Ishii; Shinichi Tsutsumi; Makoto Inoue; Takao Ichida; Masako N Hosono; Yukio Miki
Journal:  Radiol Phys Technol       Date:  2012-08-14

3.  Is RapidArc more susceptible to delivery uncertainties than dynamic IMRT?

Authors:  Gregory T Betzel; Byong Yong Yi; Ying Niu; Cedric X Yu
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

4.  Sensitivity of array detector measurements in determining shifts of MLC leaf positions.

Authors:  Qingyang Shang; Andrew Godley; Long Huang; Peng Qi; Ping Xia
Journal:  J Appl Clin Med Phys       Date:  2017-08-11       Impact factor: 2.102

5.  Analysis of direct clinical consequences of MLC positional errors in volumetric-modulated arc therapy using 3D dosimetry system.

Authors:  Karthikeyan Nithiyanantham; Ganesh K Mani; Vikraman Subramani; Lutz Mueller; Karrthick K Palaniappan; Tejinder Kataria
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

6.  On the sensitivity of TG-119 and IROC credentialing to TPS commissioning errors.

Authors:  Drew McVicker; Fang-Fang Yin; Justus D Adamson
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

7.  Rounded leaf end modeling in Pinnacle VMAT treatment planning for fixed jaw linacs.

Authors:  Lori A Young; Fei Yang; Ning Cao; Juergen Meyer
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

8.  Identification of a potential source of error for 6FFF beams delivered on an AgilityTM multileaf collimator.

Authors:  Friedlieb H Lorenz; Matthew I Paris
Journal:  J Appl Clin Med Phys       Date:  2021-03-06       Impact factor: 2.102

9.  Evaluation of dosimetric effect caused by slowing with multi-leaf collimator (MLC) leaves for volumetric modulated arc therapy (VMAT).

Authors:  Zhengzheng Xu; Iris Z Wang; Lalith K Kumaraswamy; Matthew B Podgorsak
Journal:  Radiol Oncol       Date:  2016-02-16       Impact factor: 2.991

10.  Detector system dose verification comparisons for arc therapy: couch vs. gantry mount.

Authors:  Arjunan Manikandan; Biplab Sarkar; Maitreyee Nandy; Chandra Sekaran Sureka; Michael S Gossman; Nadendla Sujatha; Vivek Thirupathur Rajendran
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.