Literature DB >> 21965036

Liver haemostasis using microbubble-enhanced ultrasound at a low acoustic intensity.

Xiaochen Zhao1, Lu Li, Hongzhi Zhao, Tao Li, Shengzheng Wu, Yu Zhong, Yang Zhao, Zheng Liu.   

Abstract

OBJECTIVES: To explore the haemostatic effects of microbubble-enhanced ultrasound (MEUS) at a very low acoustic intensity on the bleeding liver of rabbits.
METHODS: Liver incisions made on 20 rabbits were treated with a pulsed therapeutic ultrasound transducer. The transducer was operated at 831 KHz with an acoustic intensity of 0.4 W/cm(2). The treatment was coordinated with intravenous injection of microbubbles. Ultrasound only and sham treatment served as the controls. Visual bleeding score and 10-min bleeding volume were evaluated for haemostatic efficacy. Contrast-enhanced ultrasound (CEUS) was performed to assess the liver perfusion. Nine treated livers were harvested for acute histological examination.
RESULTS: Regarding the bleeding incisions made on rabbit livers, the haemorrhage stopped immediately after 2 min of MEUS treatment but bleeding continued in the controls treated by ultrasound or microbubble injection alone. The bleeding scores and the 10-min haemorrhagic volumes dropped significantly in the MEUS group compared with those of the controls (p < 0.01). The mechanism of MEUS haemostasis appears to involve the extensive swelling of hepatocytes and the haemorrhage of the portal area, which formed a joint compression on the regional liver circulation.
CONCLUSIONS: Low acoustic intensity MEUS might provide a novel method for liver haemostasis. KEY POINTS: • This animal experiment demonstrates a novel method of controlling hepatic haemorrhage • The treatment uses therapeutic ultrasound during enhancement with intravenous microbubbles • This combined therapy was more effective than ultrasound or intravenous microbubbles alone • More work is required with larger animals before potential human trials.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21965036     DOI: 10.1007/s00330-011-2273-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  23 in total

Review 1.  Hemostasis using high intensity focused ultrasound.

Authors:  S Vaezy; R Marti; P Mourad; L Crum
Journal:  Eur J Ultrasound       Date:  1999-03

2.  Effects of shear stress cultivation on cell membrane disruption and intracellular calcium concentration in sonoporation of endothelial cells.

Authors:  Juyoung Park; Zhenzhen Fan; Cheri X Deng
Journal:  J Biomech       Date:  2010-09-21       Impact factor: 2.712

3.  Vascular effects induced by combined 1-MHz ultrasound and microbubble contrast agent treatments in vivo.

Authors:  Joo Ha Hwang; Andrew A Brayman; Michael A Reidy; Thomas J Matula; Michael B Kimmey; Lawrence A Crum
Journal:  Ultrasound Med Biol       Date:  2005-04       Impact factor: 2.998

4.  Sonoporation from jetting cavitation bubbles.

Authors:  Claus-Dieter Ohl; Manish Arora; Roy Ikink; Nico de Jong; Michel Versluis; Michael Delius; Detlef Lohse
Journal:  Biophys J       Date:  2006-09-01       Impact factor: 4.033

5.  Correlation between inertial cavitation dose and endothelial cell damage in vivo.

Authors:  Joo Ha Hwang; Juan Tu; Andrew A Brayman; Thomas J Matula; Lawrence A Crum
Journal:  Ultrasound Med Biol       Date:  2006-10       Impact factor: 2.998

6.  Edgar J. Poth Lecture. Critical decisions in the management of hepatic trauma.

Authors:  E E Moore
Journal:  Am J Surg       Date:  1984-12       Impact factor: 2.565

7.  Liver hemostasis using high-intensity focused ultrasound.

Authors:  S Vaezy; R Martin; U Schmiedl; M Caps; S Taylor; K Beach; S Carter; P Kaczkowski; G Keilman; S Helton; W Chandler; P Mourad; M Rice; R Roy; L Crum
Journal:  Ultrasound Med Biol       Date:  1997       Impact factor: 2.998

8.  Contrast-enhanced two- and three-dimensional sonography for evaluation of intra-abdominal hemorrhage.

Authors:  Ji-Bin Liu; Daniel A Merton; Barry B Goldberg; Nandkumar M Rawool; William T Shi; Flemming Forsberg
Journal:  J Ultrasound Med       Date:  2002-02       Impact factor: 2.153

9.  Intracellular delivery and calcium transients generated in sonoporation facilitated by microbubbles.

Authors:  Z Fan; R E Kumon; J Park; C X Deng
Journal:  J Control Release       Date:  2009-10-07       Impact factor: 9.776

10.  Impact of myocardial contrast echocardiography on vascular permeability: comparison of three different contrast agents.

Authors:  Peng Li; William F Armstrong; Douglas L Miller
Journal:  Ultrasound Med Biol       Date:  2004-01       Impact factor: 2.998

View more
  6 in total

1.  Hemostatic mechanism underlying microbubble-enhanced non-focused ultrasound in the treatment of a rabbit liver trauma model.

Authors:  Da-Wei Zhao; Meng Tian; Jian-Zheng Yang; Peng Du; Jie Bi; Xinjian Zhu; Tao Li
Journal:  Exp Biol Med (Maywood)       Date:  2016-10-04

Review 2.  Emerging non-cancer applications of therapeutic ultrasound.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Int J Hyperthermia       Date:  2015-03-20       Impact factor: 3.914

3.  Hemostatic effects of microbubble-enhanced low-intensity ultrasound in a liver avulsion injury model.

Authors:  Guiying Feng; Jianhua Liu; Xiaochen Zhao; Jinglu Wei; Wencai Ou; Shuyi Xiao; Zhiwen Hu; Hongqin Wei; Zheng Liu
Journal:  PLoS One       Date:  2014-05-01       Impact factor: 3.240

4.  Drug Release from Phase-Changeable Nanodroplets Triggered by Low-Intensity Focused Ultrasound.

Authors:  Yang Cao; Yuli Chen; Tao Yu; Yuan Guo; Fengqiu Liu; Yuanzhi Yao; Pan Li; Dong Wang; Zhigang Wang; Yu Chen; Haitao Ran
Journal:  Theranostics       Date:  2018-02-02       Impact factor: 11.556

5.  A retrospective analysis on the diagnostic value of ultrasound-guided percutaneous biopsy for peritoneal lesions.

Authors:  Jianhong Wang; Liucun Gao; Shanhong Tang; Tao Li; Yiming Lei; Huahong Xie; Jie Liang; Baojun Chen; Xian Wang; Daiming Fan
Journal:  World J Surg Oncol       Date:  2013-10-02       Impact factor: 2.754

6.  Promoting the effect of microbubble-enhanced ultrasound on hyperthermia in rabbit liver.

Authors:  Yuwen Yang; Huanqian Luo; Yang Zhao; Lu Li; Yan He; Fen Xi; Hai Jin; Ruru Gao; Qiong Luo; Jianhua Liu
Journal:  J Med Ultrason (2001)       Date:  2022-01-24       Impact factor: 1.314

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.