Contrast-enhanced two- and three-dimensional sonography for evaluation of intra-abdominal hemorrhage.

Ji-Bin Liu1, Daniel A Merton, Barry B Goldberg, Nandkumar M Rawool, William T Shi, Flemming Forsberg.   

Abstract

OBJECTIVE: To determine whether a contrast agent enhances sonographic detection of bleeding sites in the abdomen and whether contrast-enhanced three-dimensional sonography provides additional information compared with contrast-enhanced two-dimensional sonography.
METHODS: Bleeding sites were created within the livers (n = 3), spleens (n = 5), and kidneys (n = 3) of 3 dogs. A sonographic contrast agent with vascular and parenchymal enhancement capabilities was administered intravenously at a dose of 0.02 mL/kg. Before and after each contrast agent injection, the bleeding sites were imaged with two- and three-dimensional sonography in gray scale harmonic imaging and color flow modes. Sonographic findings were compared with gross pathologic findings.
RESULTS: Noncontrast-enhanced sonography was not able to show the specific location of the active bleeding in any of the organs evaluated. The contrast agent enhanced the sonographic detection of blood flow in normal vessels and extravasated blood from damaged vessels or organs in all cases. Intrasplenic and intrahepatic hematomas were better identified on delayed imaging sequences because there was marked enhancement of the normal parenchyma, whereas the hematomas remained unenhanced. Reconstructed three-dimensional sonography showed spatial relationships of the bleeding sites and surrounding structures. Gross pathologic findings were consistent with the contrast-enhanced sonographic results.
CONCLUSIONS: Contrast-enhanced sonography improves the detection and evaluation of abdominal bleeding sites. Contrast-enhanced three-dimensional sonography appears to provide additional information when compared with two-dimensional sonography.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11833872     DOI: 10.7863/jum.2002.21.2.161

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  6 in total

Review 1.  What is the current situation in liver imaging?

Authors:  M M Uggowitzer
Journal:  Eur Radiol       Date:  2003-11       Impact factor: 5.315

2.  Efficacy of contrast-enhanced ultrasonography in detecting graft rupture sites after abdominal aortic aneurysm repair.

Authors:  Koji Nakanishi; Ryoji Watanabe; Shuji Shimizu; Mikizo Nakai
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-11-11

3.  Liver haemostasis using microbubble-enhanced ultrasound at a low acoustic intensity.

Authors:  Xiaochen Zhao; Lu Li; Hongzhi Zhao; Tao Li; Shengzheng Wu; Yu Zhong; Yang Zhao; Zheng Liu
Journal:  Eur Radiol       Date:  2011-10-01       Impact factor: 5.315

Review 4.  Added value of contrast-enhanced ultrasound (CEUS) with Sonovue® in the diagnosis of inferior epigastric artery pseudoaneurysm: report of a case and review of literature.

Authors:  Antonio Corvino; Fabio Sandomenico; Sergio Venanzio Setola; Fabio Corvino; Fabio Pinto; Orlando Catalano
Journal:  J Ultrasound       Date:  2019-07-20

Review 5.  Real-time, contrast-specific sonography imaging of acute splenic disorders: a pictorial review.

Authors:  Orlando Catalano; Bianca Cusati; Antonio Nunziata; Alfredo Siani
Journal:  Emerg Radiol       Date:  2004-06-03

Review 6.  Contrast-enhanced ultrasound (CEUS) in abdominal intervention.

Authors:  Dean Y Huang; Gibran T Yusuf; Mohammad Daneshi; Raymond Ramnarine; Annamaria Deganello; Maria E Sellars; Paul S Sidhu
Journal:  Abdom Radiol (NY)       Date:  2018-04