Literature DB >> 21964767

Bi-spectral index, entropy and predicted plasma propofol concentrations with target controlled infusions in Indian patients.

Goverdhan D Puri1, Preethy J Mathew, J Sethu Madhavan, Harihar V Hegde, Andreas Fiehn.   

Abstract

OBJECTIVE: Many processed electroencephalographic signals are used now to help the anaesthesiologist titrate the depth of sedation. We investigated the relationship between target plasma propofol concentration and objective end-points of sedation- Bispectral Index (BIS), State Entropy (SE) and Response Entropy (RE)-at clinical end-points as assessed by Modified Observer Assessment of Alertness/sedation Scale (MOAAS) in Indian patients.
METHODS: Eighteen ASA 1 and 2 Indian adult patients scheduled to undergo elective surgery were included. The target control infusion (TCI) of propofol was administered using 'Diprifusor'. The level of sedation was assessed using MOAAS by the anaesthesiologist. BIS, SE, RE were recorded throughout. TCI was started at 0.5 μg/ml and increased by 0.5 μg/ml every 6 min till MOAAS scores reached 0 or there was sustained BIS value less than 30.
RESULTS: The EC(50) and EC(95) of predicted plasma propofol concentration for loss of consciousness (assessed by loss of response to verbal command), were 2.3 and 2.8 μg/ml respectively and for loss of response to painful stimuli (trapezius squeeze) were 4.0 and 5.0 μg/ml respectively. The BIS and entropy values (EC(50) and EC(95)) for loss of consciousness and response to painful stimuli in Indian patients were estimated. The preliminary relation of target plasma propofol concentration with BIS was found to be BIS = 100.5-16.4 × (Target concentration).
CONCLUSIONS: The target plasma propofol concentrations required to produce unconsciousness and loss of response to painful stimuli in Indian patients have been estimated. Also, the relations between target plasma concentration and objective measures of different levels of anaesthesia have been established.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21964767     DOI: 10.1007/s10877-011-9309-x

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  18 in total

1.  Pharmacokinetic model driven infusion of propofol in children.

Authors:  B Marsh; M White; N Morton; G N Kenny
Journal:  Br J Anaesth       Date:  1991-07       Impact factor: 9.166

2.  TCI : Target controlled infusion, or totally confused infusion? Call for an optimised population based pharmacokinetic model for propofol.

Authors:  Mats Enlund
Journal:  Ups J Med Sci       Date:  2008       Impact factor: 2.384

Review 3.  A primer for EEG signal processing in anesthesia.

Authors:  I J Rampil
Journal:  Anesthesiology       Date:  1998-10       Impact factor: 7.892

Review 4.  The development of 'Diprifusor': a TCI system for propofol.

Authors:  J B Glen
Journal:  Anaesthesia       Date:  1998-04       Impact factor: 6.955

5.  Comparison of the effect-site k(eO)s of propofol for blood pressure and EEG bispectral index in elderly and younger patients.

Authors:  T Kazama; K Ikeda; K Morita; M Kikura; M Doi; T Ikeda; T Kurita; Y Nakajima
Journal:  Anesthesiology       Date:  1999-06       Impact factor: 7.892

6.  Spectral entropy and bispectral index as measures of the electroencephalographic effects of sevoflurane.

Authors:  Richard Klaus Ellerkmann; Vidal-Markus Liermann; Thorsten Michael Alves; Ingobert Wenningmann; Sascha Kreuer; Wolfram Wilhelm; Heiko Roepcke; Andreas Hoeft; Jörgen Bruhn
Journal:  Anesthesiology       Date:  2004-12       Impact factor: 7.892

7.  Relationship between bispectral index, auditory evoked potential index and effect-site EC50 for propofol at two clinical end-points.

Authors:  S E Milne; A Troy; M G Irwin; G N C Kenny
Journal:  Br J Anaesth       Date:  2003-02       Impact factor: 9.166

8.  Reduction in the incidence of awareness using BIS monitoring.

Authors:  A Ekman; M-L Lindholm; C Lennmarken; R Sandin
Journal:  Acta Anaesthesiol Scand       Date:  2004-01       Impact factor: 2.105

9.  Prediction of movement using bispectral electroencephalographic analysis during propofol/alfentanil or isoflurane/alfentanil anesthesia.

Authors:  J M Vernon; E Lang; P S Sebel; P Manberg
Journal:  Anesth Analg       Date:  1995-04       Impact factor: 5.108

10.  Anesthetic depth defined using multiple noxious stimuli during isoflurane/oxygen anesthesia. I. Motor reactions.

Authors:  A M Zbinden; M Maggiorini; S Petersen-Felix; R Lauber; D A Thomson; C E Minder
Journal:  Anesthesiology       Date:  1994-02       Impact factor: 7.892

View more
  6 in total

1.  Unlike History, Should a Simulator Not Repeat Itself?

Authors:  Samsun Lampotang
Journal:  Simul Healthc       Date:  2015-12       Impact factor: 1.929

2.  Race-Specific Pharmacodynamic Model of Propofol-Induced Loss of Consciousness.

Authors:  Samsun Lampotang; David E Lizdas; Hartmut Derendorf; Nikolaus Gravenstein; Benjamin Lok; John P Quarles
Journal:  J Clin Pharmacol       Date:  2016-03-28       Impact factor: 3.126

3.  Effect of preoperative anxiety on spectral entropy during induction with propofol.

Authors:  Yun Hong Kim; Won-Jun Choi
Journal:  Korean J Anesthesiol       Date:  2013-08-27

4.  Effect site concentration of propofol at induction and recovery of anaesthesia - A correlative dose-response study.

Authors:  Vasanth Sukumar; Arathi Radhakrishnan; Venkatesh H Keshavan
Journal:  Indian J Anaesth       Date:  2018-04

5.  Target controlled infusion total intravenous anaesthesia and Indian patients: Do we need our own data?

Authors:  Goverdhan Dutt Puri
Journal:  Indian J Anaesth       Date:  2018-04

Review 6.  Raw and processed electroencephalography in modern anesthesia practice: a brief primer on select clinical applications.

Authors:  Ki Hwa Lee; Talmage D Egan; Ken B Johnson
Journal:  Korean J Anesthesiol       Date:  2021-08-24
  6 in total