PURPOSE: To test the potential of a new reconstruction algorithm with Monte Carlo-based scatter correction in half-time myocardial perfusion single-photon emission computed tomography (SPECT).
MATERIALS AND METHODS: The mathematical four-dimensional NURBS-based Cardiac-Torso phantom and the SIMIND Monte Carlo simulation package were used to simulate full-time and half-time SPECT projection data. The data were reconstructed using the standard ordered subset expectation maximization-based algorithm and the new Monte Carlo-based algorithm. Defect contrast, myocardium versus ventricle contrast and resolution were calculated. In addition to the simulation studies, full-time and half-time SPECT projection data of 30 patients were reconstructed with the standard and the new method. The patient data were qualitatively evaluated by four nuclear medicine experts on a scale from 1 (poor quality) to 5 (high quality).
RESULTS: The new reconstruction method with half-time data produced higher contrast and better resolution in the simulations and also achieved higher qualitative scores in the patient study than the standard reconstruction with full-time data.
CONCLUSION: Half-time myocardial perfusion imaging using the new reconstruction algorithm with Monte Carlo-based scatter correction produced images with superior quality when compared with full-time imaging with standard reconstruction.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21956490     DOI: 10.1097/MNM.0b013e328349c765

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  6 in total

1.  Comparison of attenuation, dual-energy-window, and model-based scatter correction of low-count SPECT to 82Rb PET/CT quantified myocardial perfusion scores.

Authors:  R Glenn Wells; Karen Soueidan; Rachel Timmins; Terrence D Ruddy
Journal:  J Nucl Cardiol       Date:  2013-06-05       Impact factor: 5.952

2.  Adaptive Autoregressive Model for Reduction of Noise in SPECT.

Authors:  Reijo Takalo; Heli Hytti; Heimo Ihalainen; Antti Sohlberg
Journal:  Comput Math Methods Med       Date:  2015-05-18       Impact factor: 2.238

3.  Phantom and clinical evaluation of the effect of full Monte Carlo collimator modelling in post-SIRT yttrium-90 Bremsstrahlung SPECT imaging.

Authors:  Charlotte A Porter; Kevin M Bradley; Eero T Hippeläinen; Matthew D Walker; Daniel R McGowan
Journal:  EJNMMI Res       Date:  2018-01-22       Impact factor: 3.138

4.  Optimisation of simultaneous tl-201/tc-99m dual isotope reconstruction with monte-carlo-based scatter correction.

Authors:  Tuija Kangasmaa; Jyrki Kuikka; Antti Sohlberg
Journal:  Int J Mol Imaging       Date:  2012-11-19

5.  Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR.

Authors:  Eero Hippeläinen; Teemu Mäkelä; Touko Kaasalainen; Erna Kaleva
Journal:  EJNMMI Phys       Date:  2017-07-19

6.  Analysis of quantitative [I-123] mIBG SPECT/CT in a phantom and in patients with neuroblastoma.

Authors:  Samuel L Brady; Barry L Shulkin
Journal:  EJNMMI Phys       Date:  2019-12-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.