Literature DB >> 21953382

Investigation of photoplethysmographic signals and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor.

Michelle Hickey1, Neal Samuels, Nilesh Randive, R M Langford, P A Kyriacou.   

Abstract

OBJECTIVE: A reliable, continuous method of monitoring splanchnic organ oxygen saturation could allow for the early detection of malperfusion, and may prevent the onset of multiple organ failure. Current monitoring techniques have not been widely accepted in critical care monitoring. As a preliminary to developing a continuous indwelling device, this study evaluates a new handheld fiber optic photoplethysmographic (PPG) sensor for estimating the blood oxygen saturation (SpO(2)) of splanchnic organs during surgery.
METHODS: A fiber optic splanchnic PPG sensor, instrumentation system and virtual instrument were developed to facilitate PPG and SpO(2) measurement from splanchnic organs. Following Local Research Ethics Committee approval, the sensor was evaluated on seventeen ASA 1 and 2 patients undergoing open laparotomy. PPG signals were obtained from the large bowel, small bowel, liver and stomach. Simultaneous PPG signals from the finger were also obtained using an identical fiber optic sensor.
RESULTS: Good quality PPG signals with high signal-to-noise (SNR) ratios were obtained from all splanchnic sites under investigation. Analysis of the ac and dc amplitudes of the red and infrared PPG signals showed there to be a statistically significant difference between PPG signals obtained from splanchnic organs with those obtained from the finger (using fiber optic sensors). Estimated SpO(2) values from the splanchnic organs show good agreement with those obtained from the finger using both a fiber optic sensor and a commercial device. Furthermore, the results of a Bland and Altman analysis indicate that fiber optic splanchnic pulse oximetry, particularly of the bowel, may provide a suitable method for monitoring splanchnic organ perfusion.
CONCLUSION: The evaluation of a new fiber optic sensor on anaesthetized patients undergoing laparotomy demonstrated that good quality PPG signals and SpO(2) estimates can be obtained from splanchnic organs. Such a sensor may provide a useful tool for the intraoperative assessment of splanchnic perfusion.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21953382     DOI: 10.1007/s10877-011-9302-4

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  11 in total

1.  Tonometry to estimate intestinal perfusion in newborn piglets.

Authors:  M E Campbell; J E Van Aerde; P Y Cheung; D C Mayes
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-09       Impact factor: 5.747

2.  Development of a new splanchnic perfusion sensor.

Authors:  M Hickey; P A Kyriacou
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

Review 3.  Tissue hypoxia. How to detect, how to correct, how to prevent?

Authors:  C Richard
Journal:  Intensive Care Med       Date:  1996-11       Impact factor: 17.440

4.  Splanchnic oxygenation in patients undergoing abdominal aortic aneurysm repair and volume expansion with eloHAES.

Authors:  D Rittoo; P Gosling; C Bonnici; S Burnley; P Millns; M H Simms; S R G Smith; R K Vohra
Journal:  Cardiovasc Surg       Date:  2002-04

5.  Gastric tonometry in septic shock.

Authors:  M Hatherill; S M Tibby; R Evans; I A Murdoch
Journal:  Arch Dis Child       Date:  1998-02       Impact factor: 3.791

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  The gastrointestinal tract. The canary of the body?

Authors:  D R Dantzker
Journal:  JAMA       Date:  1993-09-08       Impact factor: 56.272

Review 8.  Monitoring of organ dysfunction in sepsis/systemic inflammatory response syndrome: novel strategies.

Authors:  T Koch; S Geiger; M J Ragaller
Journal:  J Am Soc Nephrol       Date:  2001-02       Impact factor: 10.121

9.  Pulse oximetry as a means of assessing bowel viability.

Authors:  J DeNobile; P Guzzetta; K Patterson
Journal:  J Surg Res       Date:  1990-01       Impact factor: 2.192

10.  Splanchnic and pancreatic tissue perfusion in experimental acute pancreatitis.

Authors:  P J Kinnala; K T Kuttila; J M Grönroos; T V Havia; T J Nevalainen; J H A Niinikoski
Journal:  Scand J Gastroenterol       Date:  2002-07       Impact factor: 2.423

View more
  2 in total

1.  Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.

Authors:  T Y Abay; P A Kyriacou
Journal:  J Clin Monit Comput       Date:  2017-05-25       Impact factor: 2.502

2.  Machine Perfusion of Liver Grafts With Implantable Oxygen Biosensors: Proof of Concept Study in a Rodent Model.

Authors:  Uwe Scheuermann; Mohamed M Ibrahim; John Yerxa; William Parker; Matthew G Hartwig; Bruce Klitzman; Andrew S Barbas
Journal:  Transplant Direct       Date:  2019-06-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.