Assessment of depth of anesthesia: PRST score versus bispectral index.

Jasmina Smajic1, Mirsada Praso, Mirsad Hodzic, Samir Hodzic, Amna Srabovic-Okanovic, Nedim Smajic, Zinka Djonlagic.   

Abstract

UNLABELLED: Assessment of depth of anesthesia is the basis in anesthesiologists work because the occurrence of awareness during general anesthesia is important due to stress, which is caused in the patient at that moment, and due to complications that may arise later. There are subjective and objective methods used to estimate the depth of anesthesia. The aim of this study was to assess the depth of anesthesia based on clinical parameters and on the basis bispectral index, and determine the part of bispectral monitoring in support to clinical assessment.
MATERIAL AND METHODS: Sixty patients divided into two groups were analyzed in a prospective study. In first group (group 1), the depth of anesthesia was assessed by PRST score, and in the second group (group 2) was assessed by bispectral monitoring with determination PRST score concurrently. In both groups PRST score was assessed in four periods, while bispectral monitoring is used continuously. For analysis were used the BIS index values from the equivalent periods as PRST scores. PRST score value 0-3, and BIS index 40-60 were considered as adequate depth of anesthesia. The results showed that in our study were not waking patients during the surgery. In the group where the depth of anesthesia assessed clinically, we had a few of respondents (13%) for whom at some point were present indicators of light anesthesia. Postoperative interview excluded the possibility of intraoperative awareness. In the second group of patients and objective and clinical assessment indicated at all times to adequate depth of anesthesia.
CONCLUSION: The use of BIS monitoring with clinical assessment allows anesthesiologists precise decision-making in balancing and dosage of anesthetics and other drugs, as well as treatment in certain situations.

Entities:  

Mesh:

Year:  2011        PMID: 21950227     DOI: 10.5455/medarh.2011.65.216-220

Source DB:  PubMed          Journal:  Med Arh        ISSN: 0350-199X


  4 in total

1.  The discriminatory value of cardiorespiratory interactions in distinguishing awake from anaesthetised states: a randomised observational study.

Authors:  D A Kenwright; A Bernjak; T Draegni; S Dzeroski; M Entwistle; M Horvat; P Kvandal; S A Landsverk; P V E McClintock; B Musizza; J Petrovčič; J Raeder; L W Sheppard; A F Smith; T Stankovski; A Stefanovska
Journal:  Anaesthesia       Date:  2015-09-09       Impact factor: 6.955

2.  Falsely increased bispectral index values by convective air warming system during kidney transplantation.

Authors:  Se Hun Kim; Byeong-Cheol Lee; Yong Han Kim
Journal:  Pak J Med Sci       Date:  2016 May-Jun       Impact factor: 1.088

3.  Evaluation of effect of entropy monitoring on isoflurane consumption and recovery from anesthesia.

Authors:  Kush Ashokkumar Goyal; Anitha Nileshwar; Lokvendra Singh Budania; Yogesh Gaude; Shaji Mathew; Shriram Vaidya
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2017 Oct-Dec

4.  Effect of anesthesia depth on postoperative clinical outcome in patients with supratentorial tumor (DEPTH): study protocol for a randomized controlled trial.

Authors:  Qianyu Cui; Yuming Peng; Xiaoyuan Liu; Bo Jia; Jia Dong; Ruquan Han
Journal:  BMJ Open       Date:  2017-09-11       Impact factor: 2.692