Literature DB >> 21946702

Rapid detection of coronary artery stenoses with real-time perfusion echocardiography during regadenoson stress.

Thomas R Porter1, Mary Adolphson, Robin R High, Lynette M Smith, Joan Olson, Michelle Erdkamp, Feng Xie, Edward O'Leary, Benjamin F Wong, Susan Eifert-Rain, Mary E Hagen, Sahar S Abdelmoneim, Sharon L Mulvagh.   

Abstract

BACKGROUND: Real-time myocardial contrast echocardiography permits the detection of myocardial perfusion abnormalities during stress echocardiography, which may improve the accuracy of the test in detecting coronary artery stenoses. We hypothesized that this technique could be used after a bolus injection of the selective A2A receptor agonist regadenoson to rapidly and safely detect coronary artery stenoses. METHODS AND
RESULTS: In 100 patients referred for quantitative coronary angiography, real-time myocardial contrast echocardiography was performed during a continuous intravenous infusion of 3% Definity at baseline and at 2-minute intervals for up to 6 minutes after a regadenoson bolus injection (400 μg). Myocardial perfusion was assessed by examination of myocardial contrast replenishment after brief high mechanical index impulses. A perfusion defect was defined as a delay (>2 seconds) in myocardial contrast replenishment in 2 contiguous segments. Wall motion was also analyzed. The overall sensitivity/specificity/accuracy for myocardial perfusion analysis in detecting a >50% diameter stenosis was 80%/74%/78%, whereas for wall motion analysis it was 60%/72%/66% (P<0.001 for differences in sensitivity). Sensitivity for myocardial perfusion analysis was highest on images obtained during the first 2 minutes after regadenoson bolus (P<0.001 compared with wall motion), whereas wall motion sensitivity was highest at the 4-to-6-minute period after the bolus. No significant side effects occurred after regadenoson bolus injection.
CONCLUSIONS: Regadenoson real-time myocardial contrast echocardiography appears to be a feasible, safe, and rapid noninvasive method for the detection of significant coronary artery stenoses.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21946702     DOI: 10.1161/CIRCIMAGING.111.966341

Source DB:  PubMed          Journal:  Circ Cardiovasc Imaging        ISSN: 1941-9651            Impact factor:   7.792


  8 in total

Review 1.  Contrast echocardiography: latest developments and clinical utility.

Authors:  Thomas R Porter; Feng Xie
Journal:  Curr Cardiol Rep       Date:  2015-03       Impact factor: 2.931

2.  Perfusion imaging with vasodilator stress echocardiography: a physiologically sound approach to coronary disease?

Authors:  Jonathan R Lindner
Journal:  Circ Cardiovasc Imaging       Date:  2011-11       Impact factor: 7.792

3.  Microvascular Dysfunction and Clinical Outcomes.

Authors:  Jonathan R Lindner
Journal:  Circ Cardiovasc Imaging       Date:  2018-10       Impact factor: 7.792

4.  Feasibility, safety and accuracy of regadenoson-atropine (REGAT) stress echocardiography for the diagnosis of coronary artery disease: an angiographic correlative study.

Authors:  Kamran Shaikh; Dee Dee Wang; Hani Saad; Mohsin Alam; Akshay Khandelwal; Kristen Brooks; Hari Iyer; Phuc Nguyen; Stephanie Boedeker; Karthik Ananthasubramaniam
Journal:  Int J Cardiovasc Imaging       Date:  2014-01-25       Impact factor: 2.357

5.  Acute hyperglycemia reduces myocardial blood flow reserve and the magnitude of reduction is associated with insulin resistance: a study in nondiabetic humans using contrast echocardiography.

Authors:  Sahar S Abdelmoneim; Mary E Hagen; Edward Mendrick; Vishwanath Pattan; Benjamin Wong; Barbara Norby; Tamara Roberson; Troy Szydel; Rita Basu; Ananda Basu; Sharon L Mulvagh
Journal:  Heart Vessels       Date:  2012-11-23       Impact factor: 2.037

6.  Myocardial contrast echocardiography assessment of perfusion abnormalities in hypertrophic cardiomyopathy.

Authors:  Paola Roldan; Sriram Ravi; James Hodovan; J Todd Belcik; Stephen B Heitner; Ahmad Masri; Jonathan R Lindner
Journal:  Cardiovasc Ultrasound       Date:  2022-09-19       Impact factor: 2.263

7.  Qualitative and quantitative assessment of adenosine triphosphate stress whole-heart dynamic myocardial perfusion imaging using 256-slice computed tomography.

Authors:  Akira Kurata; Naoto Kawaguchi; Teruhito Kido; Katsuji Inoue; Jun Suzuki; Akiyoshi Ogimoto; Jun-ichi Funada; Jitsuo Higaki; Masao Miyagawa; Mani Vembar; Teruhito Mochizuki
Journal:  PLoS One       Date:  2013-12-23       Impact factor: 3.240

8.  High versus Low Mechanical Index Imaging Diagnostic Ultrasound in Patients with Myocardial Infarction: A Therapeutic Application Study.

Authors:  Zongbao Niu; Xiaolan Lv; Jianhua Zhang; Tianping Bao
Journal:  Med Sci Monit       Date:  2020-08-13
  8 in total