Literature DB >> 21945449

Microhardness and chemical analysis of high-viscous glass-ionomer cement after 10 years of clinical service as ART restorations.

Régia Luzia Zanata1, Ana Carolina Magalhães, José Roberto Pereira Lauris, Maria Teresa Atta, Linda Wang, Maria Fidela de Lima Navarro.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the Knoop microhardness (KHN) and chemical composition of high-viscous glass-ionomer cement (HVGIC) after 10 years of clinical service.
METHODS: Six HVGIC samples were cut from 10-year ART restorations. The sections were embedded in acrylic moulds with their longitudinal profile exposed. KHN was determined by performing three sequences of five indentations at 10, 30, 50, 70 and 90 μm of HVGIC outer surface. For the control group (n=6), HVGIC specimens were stored in distilled water for 24 months. Hardness measurements were taken at days 7, 30, 60, 120, 180, 360, and 720. For chemical analysis using SEM-EDX, 10-year and control specimens were dehydrated and coated with carbon. Data were analysed using T-test and ANOVA/Tukey's test (p<0.05).
RESULTS: A significant KHN increase was observed in the control group up to the 180-day period. From this point the values stabilized and no more significant differences were found between the 10-year and the control KHN values. No statistical differences were observed amongst the KHN from inner distances compared to the outer surface of the 10-year HVGIC specimens. In one 10-year specimen, SEM-images identified the transformation of HVGIC in an altered layer with no glass filler particles detectable, and raised Ca, K and P contents.
CONCLUSIONS: KHN values of ten-year HVGIC specimens were similar to the control group values at 180-day storage period. Except for one 10-year specimen in that an altered layer could be seen, chemical composition was similar amongst the depths evaluated. Copyright Â
© 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21945449     DOI: 10.1016/j.jdent.2011.09.003

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  4 in total

1.  A self-cured glass-ionomer cement with improved antibacterial function and hardness.

Authors:  Yong Chen; Gulsah Caneli; Rashed Almousa; Kayla Hill; Sungsoo Na; Gregory G Anderson; Dong Xie
Journal:  Polym Adv Technol       Date:  2020-08-13       Impact factor: 3.348

2.  Fluoride release and mechanical properties after 1-year water storage of recent restorative glass ionomer cements.

Authors:  Maho Shiozawa; Hidekazu Takahashi; Naohiko Iwasaki
Journal:  Clin Oral Investig       Date:  2013-08-22       Impact factor: 3.573

3.  Effect of ultrasound application during setting on the mechanical properties of high viscous glass-ionomers used for ART restorations.

Authors:  Lamia E Daifalla; Enas H Mobarak
Journal:  J Adv Res       Date:  2014-06-11       Impact factor: 10.479

4.  The Effect of Disinfection with Chlorhexidine on the Shear Bond Strength of Equia Resin-Modified Glass Ionomer Cement to Dentin in Permanent Teeth after Two Thermocycling Protocols.

Authors:  Yasmin Sheikh Hasani; Mehrsa Paryab; Aida Saffarpour; Mohammad Javad Kharazifard; Mehdi Shahrabi
Journal:  J Dent (Shiraz)       Date:  2017-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.