Literature DB >> 21933798

Optimization of the atrioventricular delay during cardiac resynchronization therapy using a device for non-invasive measurement of cardiac index at rest and during exercise.

Dirk Prochnau1, Thomas Forberg, Helmut Kühnert, Matthias Heinke, Hans R Figulla, Ralf Surber.   

Abstract

AIMS: It is not clear whether cardiac resynchronization therapy (CRT) should only be optimized at rest or whether it is necessary to perform CRT optimization during exercise. Our study aims to answer this question by using an inert gas rebreathing method (Innocor®). METHODS AND
RESULTS: Twenty-seven patients with congestive heart failure and implanted CRT devices were included in the study. The aetiology of the heart failure was ischaemic in nine (33%) patients. Patients had low left ventricular ejection fraction (29 ± 8%) and enlarged LV end-diastolic diameters (63 ± 7 mm). Atrioventricular delay (AVD) was optimized at rest according to cardiac index (CI), measured by inert gas rebreathing (Innocor®). Thereafter, patients performed standardized, steady-state bicycle exercise at 30 W in sitting body position. Three AVDs were tested during exercise in a random sequence: optimized resting AVD (AVD(opt)) according to baseline measurement; AVD(opt) - 30 ms; and AVD(opt) + 30 ms. Cardiac index was measured in each AVD by inert gas rebreathing. Cardiac index increased significantly during exercise. However, neither AVD(opt) shortening nor prolongation during exercise had significant effect on CI (shortening of AVD(opt) - 30 ms was accompanied by a reduction of CI of 4.8%, prolongation of AVD(opt) + 30 ms was accompanied by a reduction of CI of 7.7%).
CONCLUSION: Shortening or lengthening of the AVD during exercise has no impact on CI in CRT patients. On the basis of our results, we conclude that in CRT patients the AVD should be programmed, fixed even during exercise.

Entities:  

Mesh:

Year:  2011        PMID: 21933798     DOI: 10.1093/europace/eur296

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  2 in total

1.  Influence of atrioventricular optimization on hemodynamic parameters and quality of life in patients with dual chamber pacemaker with ventricular lead in right ventricular outflow tract.

Authors:  Artur Klimczak; Adam S Budzikowski; Marcin Rosiak; Marzenna Zielińska; Bożena Urbanek; Karol Bartczak; Michał Chudzik; Jerzy K Wranicz
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-03-06       Impact factor: 1.468

2.  Optimisation of cardiac resynchronization therapy in clinical practice during exercise.

Authors:  M M D Molenaar; B Oude Velthuis; M F Scholten; J Y Stevenhagen; W A Wesselink; J M van Opstal
Journal:  Neth Heart J       Date:  2013-10       Impact factor: 2.380