Noninvasive intratissue refractive index shaping (IRIS) of the cornea with blue femtosecond laser light.

Lisen Xu1, Wayne H Knox, Margaret DeMagistris, Nadan Wang, Krystel R Huxlin.   

Abstract

PURPOSE: To test the feasibility of intratissue refractive index shaping (IRIS) in living corneas by using 400-nm femtosecond (fs) laser pulses (blue-IRIS). To test the hypothesis that the intrinsic two-photon absorption of the cornea allows blue-IRIS to be performed with greater efficacy than when using 800-nm femtosecond laser pulses.
METHODS: Fresh cat corneas were obtained postmortem and cut into six wedges. Blue laser pulses at 400 nm, with 100-fs pulse duration at 80 MHz were used to micromachine phase gratings into each corneal wedge at scanning speeds from 1 to 15 mm/s. Grating lines were 1 μm wide, 5 μm apart, and 150 μm below the anterior corneal surface. Refractive index (RI) changes in micromachined regions were measured immediately by recording the diffraction efficiency of inscribed gratings. Six hours later, the corneas were processed for histology, and TUNEL staining was performed to assess whether blue-IRIS causes cell death.
RESULTS: Scanning at 1 and 2 mm/s caused overt corneal damage in the form of bubbles and burns. At faster scanning speeds (5, 10, and 15 mm/s), phase gratings were created in the corneal stroma, which were shown to be pure RI changes ranging from 0.037 to 0.021 in magnitude. The magnitude of RI change was inversely related to scanning speed. TUNEL staining showed cell death only around bubbles and burns.
CONCLUSIONS: Blue-IRIS can be performed safely and effectively in living cornea. Compared with near-infrared laser pulses, blue-IRIS enhances both achievable RI change and scanning speed without the need to dope the tissue with two-photon sensitizers, increasing the clinical applicability of this technique.

Entities:  

Mesh:

Year:  2011        PMID: 21931133      PMCID: PMC3208024          DOI: 10.1167/iovs.11-7323

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  53 in total

1.  Changes in the refractive index of the stroma and its extrafibrillar matrix when the cornea swells.

Authors:  Keith M Meek; Sally Dennis; Shukria Khan
Journal:  Biophys J       Date:  2003-10       Impact factor: 4.033

2.  Corneal wound healing after photorefractive keratectomy: a 3-year confocal microscopy study.

Authors:  Jay C Erie
Journal:  Trans Am Ophthalmol Soc       Date:  2003

Review 3.  Lasers in refractive surgery: history, present, and future.

Authors:  Lance J Kugler; Ming X Wang
Journal:  Appl Opt       Date:  2010-09-01       Impact factor: 1.980

4.  Femtosecond laser-assisted corneal flap cuts: morphology, accuracy, and histopathology.

Authors:  Mike P Holzer; Tanja M Rabsilber; Gerd U Auffarth
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-07       Impact factor: 4.799

Review 5.  Preserving the cornea: corneal storage media.

Authors:  Bennie H Jeng
Journal:  Curr Opin Ophthalmol       Date:  2006-08       Impact factor: 3.761

6.  Corneal femtosecond laser keratotomy results in isolated stromal injury and favorable wound-healing response.

Authors:  Christian Meltendorf; Guido J Burbach; Jens Bühren; Reinhold Bug; Christian Ohrloff; Thomas Deller
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-05       Impact factor: 4.799

7.  Femtosecond laser micromachining of waveguides in silicone-based hydrogel polymers.

Authors:  Li Ding; Richard I Blackwell; Jay F Künzler; Wayne H Knox
Journal:  Appl Opt       Date:  2008-06-10       Impact factor: 1.980

8.  Intact corneal epithelium is essential for the prevention of stromal haze after laser assisted in situ keratomileusis.

Authors:  K Nakamura; D Kurosaka; H Bissen-Miyajima; K Tsubota
Journal:  Br J Ophthalmol       Date:  2001-02       Impact factor: 4.638

9.  First clinical results with the femtosecond neodynium-glass laser in refractive surgery.

Authors:  Imola Ratkay-Traub; Istvan E Ferincz; Tibor Juhasz; Ron M Kurtz; Ronald R Krueger
Journal:  J Refract Surg       Date:  2003 Mar-Apr       Impact factor: 3.573

10.  Reproducibility of flap thickness with IntraLase FS and Moria LSK-1 and M2 microkeratomes.

Authors:  Jonathan H Talamo; Jeremy Meltzer; John Gardner
Journal:  J Refract Surg       Date:  2006-06       Impact factor: 3.573

View more
  7 in total

1.  Finesse of transparent tissue cutting by ultrafast lasers at various wavelengths.

Authors:  Jenny Wang; Georg Schuele; Daniel Palanker
Journal:  J Biomed Opt       Date:  2015       Impact factor: 3.170

2.  First demonstration of ocular refractive change using blue-IRIS in live cats.

Authors:  Daniel E Savage; Daniel R Brooks; Margaret DeMagistris; Lisen Xu; Scott MacRae; Jonathan D Ellis; Wayne H Knox; Krystel R Huxlin
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-07-01       Impact factor: 4.799

3.  Comparable change in stromal refractive index of cat and human corneas following blue-IRIS.

Authors:  Kaitlin T Wozniak; Sara M Gearhart; Daniel E Savage; Jonathan D Ellis; Wayne H Knox; Krystel R Huxlin
Journal:  J Biomed Opt       Date:  2017-05-01       Impact factor: 3.170

4.  Blue-LIRIC in the rabbit cornea: efficacy, tissue effects, and repetition rate scaling.

Authors:  Ruiting Huang; Dan Yu; Daniel Savage; Kaitlin Wozniak; Len Zheleznyak; Wayne H Knox; Krystel R Huxlin
Journal:  Biomed Opt Express       Date:  2022-03-22       Impact factor: 3.562

5.  Contrasting cellular damage after Blue-IRIS and Femto-LASIK in cat cornea.

Authors:  Kaitlin T Wozniak; Noah Elkins; Daniel R Brooks; Daniel E Savage; Scott MacRae; Jonathan D Ellis; Wayne H Knox; Krystel R Huxlin
Journal:  Exp Eye Res       Date:  2017-08-31       Impact factor: 3.467

Review 6.  Nonlinear optical crosslinking (NLO CXL) for correcting refractive errors.

Authors:  Samantha Bradford; Eric Mikula; Tibor Juhasz; Donald J Brown; James V Jester
Journal:  Exp Eye Res       Date:  2020-08-23       Impact factor: 3.467

7.  Optical side-effects of fs-laser treatment in refractive surgery investigated by means of a model eye.

Authors:  Roland Ackermann; Robert Kammel; Marina Merker; Andreas Kamm; Andreas Tünnermann; Stefan Nolte
Journal:  Biomed Opt Express       Date:  2013-01-10       Impact factor: 3.732

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.