PURPOSE: To test the feasibility of intratissue refractive index shaping (IRIS) in living corneas by using 400-nm femtosecond (fs) laser pulses (blue-IRIS). To test the hypothesis that the intrinsic two-photon absorption of the cornea allows blue-IRIS to be performed with greater efficacy than when using 800-nm femtosecond laser pulses. METHODS: Fresh cat corneas were obtained postmortem and cut into six wedges. Blue laser pulses at 400 nm, with 100-fs pulse duration at 80 MHz were used to micromachine phase gratings into each corneal wedge at scanning speeds from 1 to 15 mm/s. Grating lines were 1 μm wide, 5 μm apart, and 150 μm below the anterior corneal surface. Refractive index (RI) changes in micromachined regions were measured immediately by recording the diffraction efficiency of inscribed gratings. Six hours later, the corneas were processed for histology, and TUNEL staining was performed to assess whether blue-IRIS causes cell death. RESULTS: Scanning at 1 and 2 mm/s caused overt corneal damage in the form of bubbles and burns. At faster scanning speeds (5, 10, and 15 mm/s), phase gratings were created in the corneal stroma, which were shown to be pure RI changes ranging from 0.037 to 0.021 in magnitude. The magnitude of RI change was inversely related to scanning speed. TUNEL staining showed cell death only around bubbles and burns. CONCLUSIONS: Blue-IRIS can be performed safely and effectively in living cornea. Compared with near-infrared laser pulses, blue-IRIS enhances both achievable RI change and scanning speed without the need to dope the tissue with two-photon sensitizers, increasing the clinical applicability of this technique.
PURPOSE: To test the feasibility of intratissue refractive index shaping (IRIS) in living corneas by using 400-nm femtosecond (fs) laser pulses (blue-IRIS). To test the hypothesis that the intrinsic two-photon absorption of the cornea allows blue-IRIS to be performed with greater efficacy than when using 800-nm femtosecond laser pulses. METHODS: Fresh cat corneas were obtained postmortem and cut into six wedges. Blue laser pulses at 400 nm, with 100-fs pulse duration at 80 MHz were used to micromachine phase gratings into each corneal wedge at scanning speeds from 1 to 15 mm/s. Grating lines were 1 μm wide, 5 μm apart, and 150 μm below the anterior corneal surface. Refractive index (RI) changes in micromachined regions were measured immediately by recording the diffraction efficiency of inscribed gratings. Six hours later, the corneas were processed for histology, and TUNEL staining was performed to assess whether blue-IRIS causes cell death. RESULTS: Scanning at 1 and 2 mm/s caused overt corneal damage in the form of bubbles and burns. At faster scanning speeds (5, 10, and 15 mm/s), phase gratings were created in the corneal stroma, which were shown to be pure RI changes ranging from 0.037 to 0.021 in magnitude. The magnitude of RI change was inversely related to scanning speed. TUNEL staining showed cell death only around bubbles and burns. CONCLUSIONS:Blue-IRIS can be performed safely and effectively in living cornea. Compared with near-infrared laser pulses, blue-IRIS enhances both achievable RI change and scanning speed without the need to dope the tissue with two-photon sensitizers, increasing the clinical applicability of this technique.
Authors: Christian Meltendorf; Guido J Burbach; Jens Bühren; Reinhold Bug; Christian Ohrloff; Thomas Deller Journal: Invest Ophthalmol Vis Sci Date: 2007-05 Impact factor: 4.799
Authors: Imola Ratkay-Traub; Istvan E Ferincz; Tibor Juhasz; Ron M Kurtz; Ronald R Krueger Journal: J Refract Surg Date: 2003 Mar-Apr Impact factor: 3.573
Authors: Daniel E Savage; Daniel R Brooks; Margaret DeMagistris; Lisen Xu; Scott MacRae; Jonathan D Ellis; Wayne H Knox; Krystel R Huxlin Journal: Invest Ophthalmol Vis Sci Date: 2014-07-01 Impact factor: 4.799
Authors: Kaitlin T Wozniak; Sara M Gearhart; Daniel E Savage; Jonathan D Ellis; Wayne H Knox; Krystel R Huxlin Journal: J Biomed Opt Date: 2017-05-01 Impact factor: 3.170
Authors: Ruiting Huang; Dan Yu; Daniel Savage; Kaitlin Wozniak; Len Zheleznyak; Wayne H Knox; Krystel R Huxlin Journal: Biomed Opt Express Date: 2022-03-22 Impact factor: 3.562
Authors: Kaitlin T Wozniak; Noah Elkins; Daniel R Brooks; Daniel E Savage; Scott MacRae; Jonathan D Ellis; Wayne H Knox; Krystel R Huxlin Journal: Exp Eye Res Date: 2017-08-31 Impact factor: 3.467
Authors: Roland Ackermann; Robert Kammel; Marina Merker; Andreas Kamm; Andreas Tünnermann; Stefan Nolte Journal: Biomed Opt Express Date: 2013-01-10 Impact factor: 3.732