Literature DB >> 2193042

Intrinsic PEEP on static pressure-volume curves.

R Fernández1, J Mancebo, L Blanch, S Benito, N Calaf, A Net.   

Abstract

The static pressure volume (PV) curve of the total respiratory system is a well established method to assess pulmonary mechanics during respiratory failure. We have tested the impact of auto-PEEP on the PV curve determination in 16 COPD patients. An isovolumic pressure increment (IPI) was found at the beginning of the curve and a close correlation between IPI and auto-PEEP level (r = 0.962) p less than 0.001) was observed. The regression equation was not significantly different from the identity line. We conclude that the appearance of IPI in PV curves is largely determined by auto-PEEP and it is a good estimate of the existing auto PEEP level.

Entities:  

Mesh:

Year:  1990        PMID: 2193042     DOI: 10.1007/bf01705157

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  14 in total

1.  Causes of error of respiratory pressure-volume curves in paralyzed subjects.

Authors:  J Dall'ava-Santucci; A Armaganidis; F Brunet; J F Dhainaut; G L Chelucci; J F Monsallier; A Lockhart
Journal:  J Appl Physiol (1985)       Date:  1988-01

2.  Compliance and dynamic characteristics curves in acute respiratory failure.

Authors:  R C Bone
Journal:  Crit Care Med       Date:  1976 Jul-Aug       Impact factor: 7.598

3.  Effect of intrinsic positive end-expiratory pressure on respiratory compliance.

Authors:  I Caviedes; S Benito; J Mancebo; A Net
Journal:  Crit Care Med       Date:  1986-11       Impact factor: 7.598

4.  Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation. The effect of intrinsic positive end-expiratory pressure.

Authors:  A Rossi; S B Gottfried; L Zocchi; B D Higgs; S Lennox; P M Calverley; P Begin; A Grassino; J Milic-Emili
Journal:  Am Rev Respir Dis       Date:  1985-05

5.  Effect of PEEP on the arterial minus end-tidal carbon dioxide gradient.

Authors:  L Blanch; R Fernández; S Benito; J Mancebo; A Net
Journal:  Chest       Date:  1987-09       Impact factor: 9.410

6.  Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction: the auto-PEEP effect.

Authors:  P E Pepe; J J Marini
Journal:  Am Rev Respir Dis       Date:  1982-07

7.  The role of total static lung compliance in the management of severe ARDS unresponsive to conventional treatment.

Authors:  L Gattinoni; A Pesenti; M L Caspani; A Pelizzola; D Mascheroni; R Marcolin; G Iapichino; M Langer; A Agostoni; T Kolobow
Journal:  Intensive Care Med       Date:  1984       Impact factor: 17.440

8.  Volume/pressure curve of total respiratory system in paralysed patients: artefacts and correction factors.

Authors:  L Gattinoni; D Mascheroni; E Basilico; G Foti; A Pesenti; L Avalli
Journal:  Intensive Care Med       Date:  1987       Impact factor: 17.440

9.  Pulmonary compliance measurement in acute respiratory failure.

Authors:  J Mancebo; N Calaf; S Benito
Journal:  Crit Care Med       Date:  1985-07       Impact factor: 7.598

10.  The effects of ventilatory pattern on hyperinflation, airway pressures, and circulation in mechanical ventilation of patients with severe air-flow obstruction.

Authors:  D V Tuxen; S Lane
Journal:  Am Rev Respir Dis       Date:  1987-10
View more
  6 in total

Review 1.  Intrinsic positive end-expiratory pressure (PEEPi).

Authors:  A Rossi; G Polese; G Brandi; G Conti
Journal:  Intensive Care Med       Date:  1995-06       Impact factor: 17.440

2.  Tumor necrosis factor-alpha overexpression in lung disease: a single cause behind a complex phenotype.

Authors:  Lennart K A Lundblad; John Thompson-Figueroa; Timothy Leclair; Michael J Sullivan; Matthew E Poynter; Charles G Irvin; Jason H T Bates
Journal:  Am J Respir Crit Care Med       Date:  2005-04-01       Impact factor: 21.405

3.  Inflation static pressure-volume curves of the total respiratory system determined without any instrumentation other than the mechanical ventilator.

Authors:  R Fernandez; L Blanch; A Artigas
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

4.  Intrinsic PEEP determined by static pressure-volume curves--application of a novel automated occlusion method.

Authors:  M Sydow; H Burchardi; J Zinserling; T A Crozier; T Denecke; S Zielmann
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

5.  A Physiological Point of View on Expiratory (Re)action during Mechanical Ventilation.

Authors:  Savino Spadaro; Carlo Alberto Volta
Journal:  Am J Respir Crit Care Med       Date:  2020-05-15       Impact factor: 21.405

6.  Increase in lung volume originated by extrinsic PEEP in patients with auto-PEEP. The role of static lung compliance.

Authors:  E Fernández Mondéjar; G Vazquez Mata; P Navarrete Navarro; R Rivera Fernández; J M Torres Ruiz; E Carazo
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.