Literature DB >> 21930225

Comparing non-enhanced and enhanced sequences in the assessment of effusion and synovitis in knee OA: associations with clinical, macroscopic and microscopic features.

D Loeuille1, N Sauliere, J Champigneulle, A C Rat, A Blum, I Chary-Valckenaere.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate synovial membrane (SM) inflammation and joint effusion scores by semiquantitative magnetic resonance imaging (MRI) assessment with and without enhanced sequences. Gold standards used for comparison were microscopic examination of SM biopsies for SM inflammation and joint volume measurement (JVM) after arthrocentesis for effusion.
METHODS: Patients (n = 30) fulfilling ACR criteria for knee osteoarthritis (OA) and requiring joint lavage, were evaluated with MRI: (1) SM inflammation was assessed by Whole-Organ Magnetic Resonance Imaging Score (WORMS) on T2 weighted sequences (T2w) a composite score assessing together synovitis and effusion, and the MRI-synovitis score (based on synovitis thickening in five regions of interest) on a T1-weighted fat sat sequence after contrast agent injection (T1wCE). (2) Joint effusion was evaluated by MRI-effusion score (T1wCE) and the WORMS (T2w). JVM was measured after arthrocentesis, and microscopic SM inflammation was determined in SM samples (n = 86). Correlations between MRI scores and clinical, biologic and histologic parameters were studied.
RESULTS: Both scores for effusion were well correlated [r = 0.82 (0.65-0.91); P < 0.001] and presented excellent intraclass correlation coefficient (ICC) for intra- and inter-observer reproducibility. MRI scores for effusion were well correlated with JVM (r = 0.60 for WORMS and r = 0.59 for MRI-effusion score). Synovitis scores were highly reproducible but moderately correlated (r = 0.63; P < 0.001). Only MRI-synovitis total score (T1wCE) was correlated with SM microscopic inflammation (r = 0.46; P = 0.01) and most strongly infiltration (r = 0.45; P < 0.005).
CONCLUSIONS: T2w sequences are adequate in assessing effusion volume in compare to joint volume by arthrocentesis but only T1wCE sequences are able to detect synovitis according to the reference of synovial biopsy.
Copyright © 2011. Published by Elsevier Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21930225     DOI: 10.1016/j.joca.2011.08.010

Source DB:  PubMed          Journal:  Osteoarthritis Cartilage        ISSN: 1063-4584            Impact factor:   6.576


  26 in total

1.  Aiming for a simpler early arthritis MRI protocol: can Gd contrast administration be eliminated?

Authors:  Wouter Stomp; Annemarie Krabben; Désirée van der Heijde; Tom W J Huizinga; Johan L Bloem; Mikkel Østergaard; Annette H M van der Helm-van Mil; Monique Reijnierse
Journal:  Eur Radiol       Date:  2015-01-31       Impact factor: 5.315

2.  The association between meniscal damage of the posterior horns and localized posterior synovitis detected on T1-weighted contrast-enhanced MRI--the MOST study.

Authors:  Frank W Roemer; David T Felson; Tianzhong Yang; Jingbo Niu; Michel D Crema; Martin Englund; Michael C Nevitt; Yuqing Zhang; John A Lynch; George Y El Khoury; James Torner; Cora E Lewis; Ali Guermazi
Journal:  Semin Arthritis Rheum       Date:  2012-12-25       Impact factor: 5.532

3.  MRI findings of treated bacterial septic arthritis.

Authors:  Guillaume Bierry; Ambrose J Huang; Connie Y Chang; Martin Torriani; Miriam A Bredella
Journal:  Skeletal Radiol       Date:  2012-03-20       Impact factor: 2.199

4.  Peripatellar synovitis: comparison between non-contrast-enhanced and contrast-enhanced MRI and association with pain. The MOST study.

Authors:  M D Crema; D T Felson; F W Roemer; J Niu; M D Marra; Y Zhang; J A Lynch; G Y El-Khoury; C E Lewis; A Guermazi
Journal:  Osteoarthritis Cartilage       Date:  2012-12-28       Impact factor: 6.576

5.  The application of T2W SPIR-FLAIR in the diagnosis of hip synovitis in patients with spondyloarthritis.

Authors:  Zhen-Guo Huang; Xiao-Liang Chen; Kai-Ning Shi; Ran Yan; He Chen; Min-Xing Yang; Bao-Xiang Gao; Queenie Chan; Guo-Chun Wang
Journal:  Br J Radiol       Date:  2016-09-23       Impact factor: 3.039

Review 6.  MRI-based semiquantitative scoring of joint pathology in osteoarthritis.

Authors:  Ali Guermazi; Frank W Roemer; Ida K Haugen; Michel D Crema; Daichi Hayashi
Journal:  Nat Rev Rheumatol       Date:  2013-01-15       Impact factor: 20.543

7.  Double-inversion recovery with synthetic magnetic resonance: a pilot study for assessing synovitis of the knee joint compared to contrast-enhanced magnetic resonance imaging.

Authors:  Jisook Yi; Young Han Lee; Ho-Taek Song; Jin-Suck Suh
Journal:  Eur Radiol       Date:  2018-11-28       Impact factor: 5.315

8.  High-resolution ultrasonography and 3.0 T magnetic resonance imaging in erosive and nodal hand osteoarthritis: high frequency of erosions in nodal osteoarthritis.

Authors:  Marianna Vlychou; Athanasios Koutroumpas; Ioannis Alexiou; Ioannis Fezoulidis; Lazaros I Sakkas
Journal:  Clin Rheumatol       Date:  2013-01-15       Impact factor: 2.980

9.  Effectiveness of aspiration in knee joint effusion management: a prospective randomized controlled study.

Authors:  Nikolaos K Paschos; Dimitrios Giotis; Khaled Abuhemoud; Anastasios D Georgoulis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-01-19       Impact factor: 4.342

10.  Synovitis in knee osteoarthritis assessed by contrast-enhanced magnetic resonance imaging (MRI) is associated with radiographic tibiofemoral osteoarthritis and MRI-detected widespread cartilage damage: the MOST study.

Authors:  Ali Guermazi; Daichi Hayashi; Frank W Roemer; Yanyan Zhu; Jingbo Niu; Michel D Crema; M Kassim Javaid; Monica D Marra; John A Lynch; George Y El-Khoury; Yuqing Zhang; Michael C Nevitt; David T Felson
Journal:  J Rheumatol       Date:  2014-01-15       Impact factor: 4.666

View more