Literature DB >> 21928623

On the Monte Carlo simulation of electron transport in the sub-1 keV energy range.

Rowan M Thomson, Iwan Kawrakow.   

Abstract

PURPOSE: The validity of "classic" Monte Carlo (MC) simulations of electron and positron transport at sub-1 keV energies is investigated in the context of quantum theory.
METHODS: Quantum theory dictates that uncertainties on the position and energy-momentum four-vectors of radiation quanta obey Heisenberg's uncertainty relation; however, these uncertainties are neglected in "classical" MC simulations of radiation transport in which position and momentum are known precisely. Using the quantum uncertainty relation and electron mean free path, the magnitudes of uncertainties on electron position and momentum are calculated for different kinetic energies; a validity bound on the classical simulation of electron transport is derived.
RESULTS: In order to satisfy the Heisenberg uncertainty principle, uncertainties of 5% must be assigned to position and momentum for 1 keV electrons in water; at 100 eV, these uncertainties are 17 to 20% and are even larger at lower energies. In gaseous media such as air, these uncertainties are much smaller (less than 1% for electrons with energy 20 eV or greater).
CONCLUSIONS: The classical Monte Carlo transport treatment is questionable for sub-1 keV electrons in condensed water as uncertainties on position and momentum must be large (relative to electron momentum and mean free path) to satisfy the quantum uncertainty principle. Simulations which do not account for these uncertainties are not faithful representations of the physical processes, calling into question the results of MC track structure codes simulating sub-1 keV electron transport. Further, the large difference in the scale at which quantum effects are important in gaseous and condensed media suggests that track structure measurements in gases are not necessarily representative of track structure in condensed materials on a micrometer or a nanometer scale.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21928623     DOI: 10.1118/1.3608904

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Microdosimetry of DNA conformations: relation between direct effect of (60)Co gamma rays and topology of DNA geometrical models in the calculation of A-, B- and Z-DNA radiation-induced damage yields.

Authors:  Farid Semsarha; Gholamreza Raisali; Bahram Goliaei; Hossein Khalafi
Journal:  Radiat Environ Biophys       Date:  2016-03-16       Impact factor: 1.925

2.  Intercomparison of dose enhancement ratio and secondary electron spectra for gold nanoparticles irradiated by X-rays calculated using multiple Monte Carlo simulation codes.

Authors:  W B Li; A Belchior; M Beuve; Y Z Chen; S Di Maria; W Friedland; B Gervais; B Heide; N Hocine; A Ipatov; A P Klapproth; C Y Li; J L Li; G Multhoff; F Poignant; R Qiu; H Rabus; B Rudek; J Schuemann; S Stangl; E Testa; C Villagrasa; W Z Xie; Y B Zhang
Journal:  Phys Med       Date:  2020-01-06       Impact factor: 2.685

3.  Multi-scale Monte Carlo simulations of gold nanoparticle-induced DNA damages for kilovoltage X-ray irradiation in a xenograft mouse model using TOPAS-nBio.

Authors:  Alexander P Klapproth; Jan Schuemann; Stefan Stangl; Tianwu Xie; Wei Bo Li; Gabriele Multhoff
Journal:  Cancer Nanotechnol       Date:  2021-10-24

4.  Nanodosimetry-Based Plan Optimization for Particle Therapy.

Authors:  Margherita Casiraghi; Reinhard W Schulte
Journal:  Comput Math Methods Med       Date:  2015-06-08       Impact factor: 2.238

  4 in total