Electromagnetic interference of cardiac rhythmic monitoring devices to radio frequency identification: analytical analysis and mitigation methodology.

Ajay Ogirala1, Joshua R Stachel, Marlin H Mickle.   

Abstract

Increasing density of wireless communication and development of radio frequency identification (RFID) technology in particular have increased the susceptibility of patients equipped with cardiac rhythmic monitoring devices (CRMD) to environmental electro magnetic interference (EMI). Several organizations reported observing CRMD EMI from different sources. This paper focuses on mathematically analyzing the energy as perceived by the implanted device, i.e., voltage. Radio frequency (RF) energy transmitted by RFID interrogators is considered as an example. A simplified front-end equivalent circuit of a CRMD sensing circuitry is proposed for the analysis following extensive black-box testing of several commercial pacemakers and implantable defibrillators. After careful understanding of the mechanics of the CRMD signal processing in identifying the QRS complex of the heart-beat, a mitigation technique is proposed. The mitigation methodology introduced in this paper is logical in approach, simple to implement and is therefore applicable to all wireless communication protocols.

Entities:  

Mesh:

Year:  2011        PMID: 21926027     DOI: 10.1109/TITB.2011.2163640

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  4 in total

1.  Sensor fusion methods for reducing false alarms in heart rate monitoring.

Authors:  Gabriel Borges; Valner Brusamarello
Journal:  J Clin Monit Comput       Date:  2015-10-06       Impact factor: 2.502

2.  Innovation and translation efforts in wireless medical connectivity, telemedicine and eMedicine: a story from the RFID Center of Excellence at the University of Pittsburgh.

Authors:  Ervin Sejdić; Michael A Rothfuss; Joshua R Stachel; Nicholas G Franconi; Kara Bocan; Michael R Lovell; Marlin H Mickle
Journal:  Ann Biomed Eng       Date:  2013-07-30       Impact factor: 3.934

3.  Adhoc electromagnetic compatibility testing of non-implantable medical devices and radio frequency identification.

Authors:  Seth J Seidman; Joshua W Guag
Journal:  Biomed Eng Online       Date:  2013-07-11       Impact factor: 2.819

4.  Feasibility results of an electromagnetic compatibility test protocol to evaluate medical devices to radio frequency identification exposure.

Authors:  Seth J Seidman; Omar Bekdash; Joshua Guag; Maryam Mehryar; Paul Booth; Paul Frisch
Journal:  Biomed Eng Online       Date:  2014-08-03       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.