Literature DB >> 21920342

Intravascular optical imaging technology for investigating the coronary artery.

Melissa J Suter1, Seemantini K Nadkarni, Giora Weisz, Atsushi Tanaka, Farouc A Jaffer, Brett E Bouma, Guillermo J Tearney.   

Abstract

There is an ever-increasing demand for new imaging methods that can provide additional information about the coronary wall to better characterize and stratify high-risk plaques, and to guide interventional and pharmacologic management of patients with coronary artery disease. While there are a number of imaging modalities that facilitate the assessment of coronary artery pathology, this review paper focuses on intravascular optical imaging modalities that provide information on the microstructural, compositional, biochemical, biomechanical, and molecular features of coronary lesions and stents. The optical imaging modalities discussed include angioscopy, optical coherence tomography, polarization sensitive-optical coherence tomography, laser speckle imaging, near-infrared spectroscopy, time-resolved laser induced fluorescence spectroscopy, Raman spectroscopy, and near-infrared fluorescence molecular imaging. Given the wealth of information that these techniques can provide, optical imaging modalities are poised to play an increasingly significant role in the evaluation of the coronary artery in the future.
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21920342      PMCID: PMC3583353          DOI: 10.1016/j.jcmg.2011.03.020

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  145 in total

1.  Second-generation optical coherence tomography in clinical practice. High-speed data acquisition is highly reproducible in patients undergoing percutaneous coronary intervention.

Authors:  Nieves Gonzalo; Guillermo J Tearney; Patrick W Serruys; Gijs van Soest; Takayuki Okamura; Héctor M García-García; Robert Jan van Geuns; Martin van der Ent; Jurgen Ligthart; Brett E Bouma; Evelyn Regar
Journal:  Rev Esp Cardiol       Date:  2010-08       Impact factor: 4.753

2.  Lipid concentrations in human coronary artery determined with high wavenumber Raman shifted light.

Authors:  Jonathan H Nazemi; James F Brennan
Journal:  J Biomed Opt       Date:  2009 May-Jun       Impact factor: 3.170

3.  Hybrid positron detection and optical coherence tomography system: design, calibration, and experimental validation with rabbit atherosclerotic models.

Authors:  Daqing Piao; Mehran M Sadeghi; Jiasheng Zhang; Yueli Chen; Albert J Sinusas; Quing Zhu
Journal:  J Biomed Opt       Date:  2005 Jul-Aug       Impact factor: 3.170

4.  Near-infrared spectroscopic characterization of human advanced atherosclerotic plaques.

Authors:  Jing Wang; Yong-Jian Geng; Bujin Guo; Tomas Klima; Birendra N Lal; James T Willerson; Ward Casscells
Journal:  J Am Coll Cardiol       Date:  2002-04-17       Impact factor: 24.094

5.  Hypersensitivity cases associated with drug-eluting coronary stents: a review of available cases from the Research on Adverse Drug Events and Reports (RADAR) project.

Authors:  Jonathan R Nebeker; Renu Virmani; Charles L Bennett; Jennifer M Hoffman; Matthew H Samore; Jorge Alvarez; Charles J Davidson; June M McKoy; Dennis W Raisch; Brian K Whisenant; Paul R Yarnold; Steven M Belknap; Dennis P West; Jonathan E Gage; Richard E Morse; Gordana Gligoric; Laura Davidson; Marc D Feldman
Journal:  J Am Coll Cardiol       Date:  2005-12-01       Impact factor: 24.094

6.  Measurement of collagen and smooth muscle cell content in atherosclerotic plaques using polarization-sensitive optical coherence tomography.

Authors:  Seemantini K Nadkarni; Mark C Pierce; B Hyle Park; Johannes F de Boer; Peter Whittaker; Brett E Bouma; Jason E Bressner; Elkan Halpern; Stuart L Houser; Guillermo J Tearney
Journal:  J Am Coll Cardiol       Date:  2007-03-21       Impact factor: 24.094

7.  Coronary angioscopy in patients with unstable angina pectoris.

Authors:  C T Sherman; F Litvack; W Grundfest; M Lee; A Hickey; A Chaux; R Kass; C Blanche; J Matloff; L Morgenstern
Journal:  N Engl J Med       Date:  1986-10-09       Impact factor: 91.245

8.  Relationship between neointimal coverage of sirolimus-eluting stents and lesion characteristics: a study with serial coronary angioscopy.

Authors:  Masanori Yamamoto; Kentaro Okamatsu; Shigenobu Inami; Masamichi Takano; Shinya Yokoyama; Takayoshi Ohba; Chikao Ibuki; Noritake Hata; Yoshihiko Seino; Kyoichi Mizuno
Journal:  Am Heart J       Date:  2009-07       Impact factor: 4.749

9.  A dual-modality optical coherence tomography and fluorescence lifetime imaging microscopy system for simultaneous morphological and biochemical tissue characterization.

Authors:  Jesung Park; Javier A Jo; Sebina Shrestha; Paritosh Pande; Qiujie Wan; Brian E Applegate
Journal:  Biomed Opt Express       Date:  2010-07-16       Impact factor: 3.732

10.  Three-dimensional visualization of intracoronary thrombus during stent implantation using the second generation, Fourier domain optical coherence tomography.

Authors:  Takayuki Okamura; Patrick W Serruys; Evelyn Regar
Journal:  Eur Heart J       Date:  2009-12-03       Impact factor: 29.983

View more
  36 in total

1.  High-performance multi-megahertz optical coherence tomography based on amplified optical time-stretch.

Authors:  Jingjiang Xu; Xiaoming Wei; Luoqin Yu; Chi Zhang; Jianbing Xu; K K Y Wong; Kevin K Tsia
Journal:  Biomed Opt Express       Date:  2015-03-18       Impact factor: 3.732

2.  Optical coherence tomography: influence of contrast concentration on image quality and diagnostic confidence.

Authors:  Florian Blachutzik; Stephan Achenbach; Holger Nef; Christian Hamm; Oliver Dörr; Niklas Boeder; Mohamed Marwan; Monique Tröbs; Reinhard Schneider; Jens Röther; Christian Schlundt
Journal:  Heart Vessels       Date:  2016-11-09       Impact factor: 2.037

Review 3.  Functional probes for cardiovascular molecular imaging.

Authors:  Yun Zeng; Jing Zhu; Junqing Wang; Paramanantham Parasuraman; Siddhardha Busi; Surya M Nauli; Yì Xiáng J Wáng; Rajasekharreddy Pala; Gang Liu
Journal:  Quant Imaging Med Surg       Date:  2018-09

4.  Design, construction, and validation of a rotary multifunctional intravascular diagnostic catheter combining multispectral fluorescence lifetime imaging and intravascular ultrasound.

Authors:  Julien Bec; Hongtao Xie; Diego R Yankelevich; Feifei Zhou; Yang Sun; Narugopal Ghata; Ralph Aldredge; Laura Marcu
Journal:  J Biomed Opt       Date:  2012-10       Impact factor: 3.170

5.  Dual-coil magnetomotive optical coherence tomography for contrast enhancement in liquids.

Authors:  Jongsik Kim; Adeel Ahmad; Stephen A Boppart
Journal:  Opt Express       Date:  2013-03-25       Impact factor: 3.894

Review 6.  Cancer imaging by optical coherence tomography: preclinical progress and clinical potential.

Authors:  Benjamin J Vakoc; Dai Fukumura; Rakesh K Jain; Brett E Bouma
Journal:  Nat Rev Cancer       Date:  2012-04-05       Impact factor: 60.716

7.  Intravascular magnetomotive optical coherence tomography of targeted early-stage atherosclerotic changes in ex vivo hyperlipidemic rabbit aortas.

Authors:  Jongsik Kim; Adeel Ahmad; Joanne Li; Marina Marjanovic; Eric J Chaney; Kenneth S Suslick; Stephen A Boppart
Journal:  J Biophotonics       Date:  2016-01       Impact factor: 3.207

8.  Intravascular Ultrasound Versus Optical Coherence Tomography for Coronary Artery Imaging - Apples and Oranges?

Authors:  Krishnaraj S Rathod; Stephen M Hamshere; Daniel A Jones; Anthony Mathur
Journal:  Interv Cardiol       Date:  2015-03

9.  Integrated IVUS-OCT Imaging for Atherosclerotic Plaque Characterization.

Authors:  Xiang Li; Jiawen Li; Joe Jing; Teng Ma; Shanshan Liang; Jun Zhang; Dilbahar Mohar; Aidan Raney; Sari Mahon; Matthew Brenner; Pranav Patel; K Kirk Shung; Qifa Zhou; Zhongping Chen
Journal:  IEEE J Sel Top Quantum Electron       Date:  2014-03       Impact factor: 4.544

10.  Multispectral fluorescence lifetime imaging system for intravascular diagnostics with ultrasound guidance: in vivo validation in swine arteries.

Authors:  Julien Bec; Dinglong M Ma; Diego R Yankelevich; Jing Liu; William T Ferrier; Jeffrey Southard; Laura Marcu
Journal:  J Biophotonics       Date:  2013-03-13       Impact factor: 3.207

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.