Literature DB >> 21920328

Serial Doppler echocardiography and tissue Doppler imaging in the detection of elevated directly measured left atrial pressure in ambulant subjects with chronic heart failure.

Jay L Ritzema1, A Mark Richards, Ian G Crozier, Christopher F Frampton, Iain C Melton, Robert N Doughty, James T Stewart, Neal Eigler, James Whiting, William T Abraham, Richard W Troughton.   

Abstract

OBJECTIVES: This study sought to determine the accuracy of Doppler echocardiography and tissue Doppler imaging (TDI) measurements in detecting elevated left atrial pressure (LAP) in ambulant subjects with chronic heart failure using directly measured LAP as the reference.
BACKGROUND: Echocardiographic indexes including the ratio of transmitral to annular early diastolic velocities (E/e') may identify raised invasively measured left ventricular filling pressures when tested in cross-sectional studies in some populations. The accuracy of these indexes when measured sequentially remains untested. We determined the accuracy of Doppler echocardiography and TDI measurements in detecting elevated directly measured LAP in ambulant subjects with stable chronic heart failure.
METHODS: Fifteen patients with New York Heart Association functional class II to III heart failure and a permanently implanted direct LAP monitoring device underwent serial echocardiography. Simultaneous resting mean LAP, Doppler mitral inflow, mitral annular TDI, and pulmonary venous inflow velocities were obtained on each occasion. Receiver-operator characteristic curve analysis was used to compare the accuracy of the Doppler variables to detect an elevated device LAP ≥15 and ≥20 mm Hg.
RESULTS: The patients (13 men, mean age: 71 years, mean left ventricular ejection fraction: 32 ± 12%) underwent 60 simultaneous echocardiographic studies and LAP measurements with a median of 4 (1 to 7) studies per patient. Mean LAP was 16.9 (range 5 to 39 mm Hg) at echocardiography (n = 60). E/e' had the greatest accuracy for detection of LAP ≥15 mm Hg with an area beneath the receiver-operator characteristic curve >0.9. In comparison, area under the curve for mitral E velocity and mitral E/A were 0.77 and 0.76, respectively (p < 0.008 vs. E/e' medial and average).
CONCLUSIONS: Single and serial measurements of mitral inflow and mitral annular TDI velocities (E/e') can reliably detect raised directly measured LAP in ambulant subjects with compensated chronic heart failure. (Hemodynamically Guided Home Self-Therapy in Severe Heart Failure Patients [HOMEOSTASIS]; NCT00547729).
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21920328     DOI: 10.1016/j.jcmg.2011.07.004

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  24 in total

1.  Slope of the anterior mitral valve leaflet: a new measurement of left ventricular unloading for left ventricular assist devices and systolic dysfunction.

Authors:  Sara C Martinez; Elisa A Bradley; Eric L Novak; Ravi Rasalingam; Ari M Cedars; Gregory A Ewald; Scott C Silvestry; Susan M Joseph
Journal:  Tex Heart Inst J       Date:  2014-06-01

Review 2.  Echocardiographic evaluation of left ventricular diastolic function: an update.

Authors:  Dimitrios Maragiannis; Sherif F Nagueh
Journal:  Curr Cardiol Rep       Date:  2015-02       Impact factor: 2.931

Review 3.  Loop diuretics in chronic heart failure: how to manage congestion?

Authors:  Justas Simonavičius; Christian Knackstedt; Hans-Peter Brunner-La Rocca
Journal:  Heart Fail Rev       Date:  2019-01       Impact factor: 4.214

Review 4.  [Implantable hemodynamic monitoring devices].

Authors:  M Seifert; C Butter
Journal:  Herz       Date:  2015-11       Impact factor: 1.443

5.  Diastolic function improvement is associated with favourable outcomes in patients with acute non-ischaemic cardiomyopathy: insights from the multicentre IMAC-2 trial.

Authors:  João L Cavalcante; Josef Marek; Richard Sheppard; Randall C Starling; Paul J Mather; Jeffrey D Alexis; Jagat Narula; Dennis M McNamara; John Gorcsan
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-11-30       Impact factor: 6.875

6.  Use and Limitations of E/e' to Assess Left Ventricular Filling Pressure by Echocardiography.

Authors:  Jae-Hyeong Park; Thomas H Marwick
Journal:  J Cardiovasc Ultrasound       Date:  2011-12-27

Review 7.  Cardiovascular failure and weaning.

Authors:  Philippe Vignon
Journal:  Ann Transl Med       Date:  2018-09

8.  Malnutrition Affects the Outcomes of Patients with Low-Output Heart Failure and Congestion.

Authors:  Li-Hung Wu; Kuan-Rau Chiou; I-Ju Pan; Shih-Hung Hsiao
Journal:  Acta Cardiol Sin       Date:  2021-05       Impact factor: 2.672

Review 9.  Inpatient Diuretic Management of Acute Heart Failure: A Practical Review.

Authors:  Saif Ali; Sharon Jung; Shuktika Nandkeolyar; Liset Stoletniy; Antoine Sakr; Frederik H Verbrugge; Anthony Hilliard; Dmitry Abramov
Journal:  Am J Cardiovasc Drugs       Date:  2021-03-12       Impact factor: 3.571

10.  Left ventricular markers of global dyssynchrony predict limited exercise capacity in heart failure, but not in patients with preserved ejection fraction.

Authors:  Gani Bajraktari; Arlind Batalli; Afrim Poniku; Artan Ahmeti; Rozafa Olloni; Violeta Hyseni; Zana Vela; Besim Morina; Rina Tafarshiku; Driton Vela; Premtim Rashiti; Edmond Haliti; Michael Y Henein
Journal:  Cardiovasc Ultrasound       Date:  2012-09-11       Impact factor: 2.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.