Literature DB >> 21912912

[Totally subcutaneous cardioverter-defibrillator (S-ICD®) : recent experience and future perspectives].

J Köbe1, S Zumhagen, F Reinke, E Schulze-Bahr, L Eckardt.   

Abstract

The implantable cardioverter defibrillator (ICD) is an established therapy for patients at risk of sudden cardiac death. Nevertheless the endocardial electrode in conventional systems plays a major role in long-term complications (difficult removal, risk of endocarditis, etc.). The totally subcutaneous ICD (S-ICD®, Cameron Health, San Clemente, CA, USA) represents a new and particularly significant development in ICD therapy which, since it requires no electrode in or on the heart, results in significantly fewer perioperative and long-term complications (e.g., thromboembolism and endocarditis risk). Although we see an indication for primary and secondary prevention, patients need to be informed about the limited data from randomized trials with the S-ICD®. As there is no permanent pacing option, patients in whom a pacemaker is indicated are not appropriate candidates for S-ICD®. In addition, patients with ventricular tachycardias that can be terminated by antitachycardic pacing are not recommended for the device. In the present article, we report our initial experience with the 18 patients implanted with the S-ICD® to date, comment on the available studies and offer a critical perspective.

Entities:  

Mesh:

Year:  2011        PMID: 21912912     DOI: 10.1007/s00059-011-3508-6

Source DB:  PubMed          Journal:  Herz        ISSN: 0340-9937            Impact factor:   1.443


  8 in total

1.  An entirely subcutaneous implantable cardioverter-defibrillator.

Authors:  Gust H Bardy; Warren M Smith; Margaret A Hood; Ian G Crozier; Iain C Melton; Luc Jordaens; Dominic Theuns; Robert E Park; David J Wright; Derek T Connelly; Simon P Fynn; Francis D Murgatroyd; Johannes Sperzel; Jörg Neuzner; Stefan G Spitzer; Andrey V Ardashev; Amo Oduro; Lucas Boersma; Alexander H Maass; Isabelle C Van Gelder; Arthur A Wilde; Pascal F van Dessel; Reinoud E Knops; Craig S Barr; Pierpaolo Lupo; Riccardo Cappato; Andrew A Grace
Journal:  N Engl J Med       Date:  2010-05-12       Impact factor: 91.245

2.  A completely subcutaneous implantable cardioverter defibrillator system functioning simultaneously with an endocardial implantable cardioverter defibrillator programmed as pacemaker.

Authors:  Jurren van Opstal; Gijs Geskes; Luuk Debie
Journal:  Europace       Date:  2010-06-29       Impact factor: 5.214

3.  Use of a primary prevention totally subcutaneous defibrillator in hypertrophic cardiomyopathy.

Authors:  Jose L Baez-Escudero; John F Beshai; Martin C Burke
Journal:  Circ Arrhythm Electrophysiol       Date:  2010-10

4.  Implantable cardioverter-defibrillator lead performance.

Authors:  William H Maisel; Daniel B Kramer
Journal:  Circulation       Date:  2008-05-27       Impact factor: 29.690

5.  Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings.

Authors:  M Mirowski; P R Reid; M M Mower; L Watkins; V L Gott; J F Schauble; A Langer; M S Heilman; S A Kolenik; R E Fischell; M L Weisfeldt
Journal:  N Engl J Med       Date:  1980-08-07       Impact factor: 91.245

6.  Necessity for surgical revision of defibrillator leads implanted long-term: causes and management.

Authors:  Jens Eckstein; Michael T Koller; Markus Zabel; Dietrich Kalusche; Beat A Schaer; Stefan Osswald; Christian Sticherling
Journal:  Circulation       Date:  2008-05-19       Impact factor: 29.690

7.  Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement.

Authors:  Lars Lickfett; Alexander Bitzen; Aravind Arepally; Khurram Nasir; Christian Wolpert; Kyung Mi Jeong; Ulf Krause; Rainer Schimpf; Thorsten Lewalter; Hugh Calkins; Werner Jung; Berndt Lüderitz
Journal:  Europace       Date:  2004-01       Impact factor: 5.214

8.  A single-centre experience of over one thousand lead extractions.

Authors:  Charles Kennergren; Christian Bjurman; Roger Wiklund; Jakob Gäbel
Journal:  Europace       Date:  2009-03-27       Impact factor: 5.214

  8 in total
  2 in total

1.  [Current status and problems of the entirely subcutaneous ICD (S-ICD®)].

Authors:  F Reinke; A Löher; J Köbe; L Eckardt
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-09

2.  [Catecholaminergic polymorphic ventricular tachycardia].

Authors:  G Frommeyer; C Pott; E Schulze-Bahr; L Eckardt
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2012-09-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.