Dual poly liner mobility optimizes wear and stability in THA: opposes.

Matthew C Lyons1, Steven J MacDonald.   

Abstract

Total hip arthroplasty (THA) is an effective intervention for the treatment of arthrosis with excellent survivorship. Nonetheless, dislocation and osteolysis remain significant complications. A dual-mobility acetabular component has been advocated to improve stability and wear. Stability is imparted by increasing the effective femoral head size, which allows a larger range of motion (ROM) before neck-socket impingement occurs. Increasing ROM, however, introduces an additional problem of bony impingement of the trochanter against the pelvis. Consequently, there is little improvement in ROM for heads >36 to 40 mm. A 0.4% incidence of instability at the larger articulation has been reported in primary THA using the dual-mobility liner, which is equivalent to reports for conventional THA. The dual-mobility liner has introduced the unique complication of intraprosthetic dislocation, where the femoral head dissociates at the smaller articulation as a result of polyethylene wear. An incidence of intraprosthetic dislocation of 3.6% has been reported, which far exceeds dislocation of conventional arthroplasty. The dual-mobility liner is a monoblock acetabular component without the capacity for augmented bony fixation. Inability to achieve primary stability has been reported as high as 18% and therefore its usefulness in revision THA is questionable. Proponents of the dual-mobility liner cite improved wear characteristics over conventional THA; however, few studies support this proposition. Retrieval studies have reported that the dual-mobility liner does not avoid wear or osteolysis. Theoretically, it is inconceivable that wear would be diminished with an additional articulation with a huge surface area, where the differential hardness has been reversed to a soft-on-hard bearing. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Year:  2011        PMID: 21902127     DOI: 10.3928/01477447-20110714-24

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  2 in total

1.  Does dual-mobility cup geometry affect posterior horizontal dislocation distance?

Authors:  Christopher Heffernan; Samik Banerjee; Jim Nevelos; James Macintyre; Kimona Issa; David C Markel; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2014-01-24       Impact factor: 4.176

Review 2.  Dislocation following total hip replacement.

Authors:  Jens Dargel; Johannes Oppermann; Gert-Peter Brüggemann; Peer Eysel
Journal:  Dtsch Arztebl Int       Date:  2014-12-22       Impact factor: 5.594

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.