Myocardial perfusion scintigraphy in Europe 2007: a survey of the European Council of Nuclear Cardiology.

Eliana Reyes1, Susanna Wiener, S Richard Underwood.   

Abstract

PURPOSE: This is the second of a series of surveys designed to assess myocardial perfusion scintigraphy (MPS) practice in Europe.
METHODS: Data were collected from 258 centres in 18 countries. The number of MPS studies per million population (pmp) was estimated assuming that the nonresponding centres performed either no studies (lower estimate) or the same number as the responding centres (upper estimate).
RESULTS: The responding centres served 24% of the population of their countries. The total number of noncardiac nuclear medicine studies was between 2,160 and 8,000 studies pmp. The total number of MPS studies was between 529 and 2,293 pmp. The median number of MPS studies per centre was 571 per year with 57% performing fewer than 500 studies per year and 23% of centres performing fewer than 250 studies per year. There was significant variation between countries, with higher numbers of MPS studies (lower limit of estimate above the mid-range of all countries combined) in Austria, Denmark, Hungary, Portugal and Slovenia, and lower numbers (upper limit of estimate below the mid-range of all countries) in Finland, Norway, Spain and Switzerland. The ratio of MPS to coronary angiography to revascularization procedures was 0.9 to 2.2 to 1. Pharmacological stress was used in 57% and technetium-99m-labelled tracers in 88% of studies. ECG gating was performed in 74% of studies and attenuation correction in 22%.
CONCLUSION: MPS utilization in Europe remains low compared with coronary angiography although there has been a 21% increase in the number of studies pmp in centres that reported in both 2005 and 2007. Pharmacological agents continue to be the predominant form of stress. Despite the widespread use of technetium-99m-labelled tracers, ECG gating is not universally performed. As in the 2005 survey, imaging aids such as attenuation and motion correction and prone imaging are not commonly used.

Entities:  

Mesh:

Year:  2011        PMID: 21894544     DOI: 10.1007/s00259-011-1923-9

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  7 in total

1.  Quality assurance in myocardial perfusion tomography: a collaborative BNCS/BNMS audit programme. British Nuclear Cardiology Society/British nuclear Medicine Society.

Authors:  E M Prvulovich; P H Jarritt; G C Vivian; S E Clarke; D J Pennell; S R Underwood
Journal:  Nucl Med Commun       Date:  1998-09       Impact factor: 1.690

2.  Procedure guidelines for radionuclide myocardial perfusion imaging.

Authors:  C Anagnostopoulos; M Harbinson; A Kelion; K Kundley; C Y Loong; A Notghi; E Reyes; W Tindale; S R Underwood
Journal:  Heart       Date:  2004-01       Impact factor: 5.994

3.  EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.

Authors:  B Hesse; K Tägil; A Cuocolo; C Anagnostopoulos; M Bardiés; J Bax; F Bengel; E Busemann Sokole; G Davies; M Dondi; L Edenbrandt; P Franken; A Kjaer; J Knuuti; M Lassmann; M Ljungberg; C Marcassa; P Y Marie; F McKiddie; M O'Connor; E Prvulovich; R Underwood; B van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07       Impact factor: 9.236

4.  Future of nuclear medicine: SPECT versus PET.

Authors:  Ali Gholamrezanejhad; Sahar Mirpour; Giuliano Mariani
Journal:  J Nucl Med       Date:  2009-07       Impact factor: 10.057

5.  Myocardial perfusion scintigraphy in Europe 2005: a survey of the European Council on Nuclear Cardiology.

Authors:  S Richard Underwood; Susanna Wiener
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-20       Impact factor: 9.236

6.  Myocardial perfusion scintigraphy in Germany in 2009: utilization and state of the practice.

Authors:  Oliver Lindner; Wolfgang Burchert; Frank M Bengel; Rainer Zimmermann; Jürgen Vom Dahl; Michael Schäfers
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-19       Impact factor: 9.236

Review 7.  Myocardial perfusion scintigraphy: the evidence.

Authors:  S R Underwood; C Anagnostopoulos; M Cerqueira; P J Ell; E J Flint; M Harbinson; A D Kelion; A Al-Mohammad; E M Prvulovich; L J Shaw; A C Tweddel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

  7 in total
  12 in total

1.  Comment on Reyes et al.: Myocardial perfusion scintigraphy in Europe 2007: a survey of the European Council of Nuclear Cardiology.

Authors:  Ali Gholamrezanezhad
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-02-04       Impact factor: 9.236

2.  Combined supine and prone imaging acquisition in cardiac SPECT: A turn for the better.

Authors:  Mylan C Cohen
Journal:  J Nucl Cardiol       Date:  2016-01-07       Impact factor: 5.952

3.  Prospective diagnostic performance of semiconductor SPECT myocardial perfusion imaging: wall thickening analysis reduces the need for an additional prone acquisition.

Authors:  Loïc Djaileb; Benjamin Dubois; Nicolas de Leiris; Julien Leenhardt; Marjorie Canu; Olivier Phan Sy; Adrien Carabelli; Bastien Boussat; Laurent Dumas; Alexis Broisat; Gérald Vanzetto; Daniel Fagret; Catherine Ghezzi; Gilles Barone-Rochette; Laurent M Riou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-07-18       Impact factor: 9.236

4.  A multicenter evaluation of the appropriate use of single-photon emission tomography myocardial perfusion imaging in Greece.

Authors:  Efstratios Moralidis; Nafsika Papadimitriou; Maria Stathaki; Xanthi Xourgia; Tryfon Spyridonidis; Andreas Fotopoulos; Dimitrios Apostolopoulos; Nikolaos Karkavitsas; Anna Gotzamani-Psarrakou
Journal:  J Nucl Cardiol       Date:  2013-02-21       Impact factor: 5.952

5.  Comparative accuracy of supine-only and combined supine-prone myocardial perfusion imaging in men.

Authors:  Vicente Taasan; Anita Wokhlu; Michael V Taasan; Raman S Dusaj; Ajay Mehta; Steven Kraft; David Winchester; David Wymer
Journal:  J Nucl Cardiol       Date:  2015-12-30       Impact factor: 5.952

Review 6.  Reducing radiation to patients and improving image quality in a real-world nuclear cardiology laboratory.

Authors:  Stephen A Bloom; Karen Meyers
Journal:  J Nucl Cardiol       Date:  2017-03-22       Impact factor: 5.952

7.  Nuclear cardiology practice in Spain.

Authors:  Amelia Jimenez-Heffernan; Santiago Aguade-Bruix; Irene Casans-Tormo
Journal:  J Nucl Cardiol       Date:  2017-05-10       Impact factor: 5.952

8.  A second look with prone SPECT myocardial perfusion imaging reduces the need for angiography in patients at low risk for cardiac death or MI.

Authors:  Nicole E Worden; Paul D Lindower; Trudy L Burns; Kanu Chatterjee; Robert M Weiss
Journal:  J Nucl Cardiol       Date:  2014-07-01       Impact factor: 5.952

9.  Caffeine reduces the sensitivity of vasodilator MPI for the detection of myocardial ischaemia: Pro.

Authors:  Eliana Reyes
Journal:  J Nucl Cardiol       Date:  2016-02-16       Impact factor: 5.952

10.  Use of myocardial perfusion imaging and estimation of associated radiation doses in Germany from 2005 to 2012.

Authors:  O Lindner; F M Bengel; M Hacker; W Schäfer; W Burchert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-02-12       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.