Literature DB >> 21889612

Comparison of QIAsymphony automated and QIAamp manual DNA extraction systems for measuring Epstein-Barr virus DNA load in whole blood using real-time PCR.

Stella Laus1, Lawrence A Kingsley, Michael Green, Robert M Wadowsky.   

Abstract

Automated and manual extraction systems have been used with real-time PCR for quantification of Epstein-Barr virus [human herpesvirus 4 (HHV-4)] DNA in whole blood, but few studies have evaluated relative performances. In the present study, the automated QIAsymphony and manual QIAamp extraction systems (Qiagen, Valencia, CA) were assessed using paired aliquots derived from clinical whole-blood specimens and an in-house, real-time PCR assay. The detection limits using the QIAsymphony and QIAamp systems were similar (270 and 560 copies/mL, respectively). For samples estimated as having ≥10,000 copies/mL, the intrarun and interrun variations were significantly lower using QIAsymphony (10.0% and 6.8%, respectively), compared with QIAamp (18.6% and 15.2%, respectively); for samples having ≤1000 copies/mL, the two variations ranged from 27.9% to 43.9% and were not significantly different between the two systems. Among 68 paired clinical samples, 48 pairs yielded viral loads ≥1000 copies/mL under both extraction systems. Although the logarithmic linear correlation from these positive samples was high (r(2) = 0.957), the values obtained using QIAsymphony were on average 0.2 log copies/mL higher than those obtained using QIAamp. Thus, the QIAsymphony and QIAamp systems provide similar EBV DNA load values in whole blood.
Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21889612      PMCID: PMC3194047          DOI: 10.1016/j.jmoldx.2011.07.006

Source DB:  PubMed          Journal:  J Mol Diagn        ISSN: 1525-1578            Impact factor:   5.568


  15 in total

1.  Quantitative analysis of cell-free Epstein-Barr virus DNA in plasma of patients with nasopharyngeal carcinoma.

Authors:  Y M Lo; L Y Chan; K W Lo; S F Leung; J Zhang; A T Chan; J C Lee; N M Hjelm; P J Johnson; D P Huang
Journal:  Cancer Res       Date:  1999-03-15       Impact factor: 12.701

2.  Reduced PCR sensitivity due to impaired DNA recovery with the MagNA Pure LC total nucleic acid isolation kit.

Authors:  Tim Schuurman; Alex van Breda; Richard de Boer; Mirjam Kooistra-Smid; Marcel Beld; Paul Savelkoul; René Boom
Journal:  J Clin Microbiol       Date:  2005-09       Impact factor: 5.948

3.  Calibration curves for real-time PCR.

Authors:  K Kay-Yin Lai; Linda Cook; Elizabeth M Krantz; Lawrence Corey; Keith R Jerome
Journal:  Clin Chem       Date:  2005-07       Impact factor: 8.327

4.  Quantitative EBV viral loads and immunosuppression alterations can decrease PTLD incidence in pediatric liver transplant recipients.

Authors:  Timothy C Lee; Barbara Savoldo; Cliona M Rooney; Helen E Heslop; Adrian P Gee; Yvette Caldwell; Neal R Barshes; Jaymee D Scott; Lisa J Bristow; Christine A O'Mahony; John A Goss
Journal:  Am J Transplant       Date:  2005-09       Impact factor: 8.086

Review 5.  Using Epstein-Barr viral load assays to diagnose, monitor, and prevent posttransplant lymphoproliferative disorder.

Authors:  Margaret L Gulley; Weihua Tang
Journal:  Clin Microbiol Rev       Date:  2010-04       Impact factor: 26.132

6.  Toward standardization of Epstein-Barr virus DNA load monitoring: unfractionated whole blood as preferred clinical specimen.

Authors:  S J Stevens; I Pronk; J M Middeldorp
Journal:  J Clin Microbiol       Date:  2001-04       Impact factor: 5.948

7.  Multicenter comparison of different real-time PCR assays for quantitative detection of Epstein-Barr virus.

Authors:  R T Hayden; K M Hokanson; S B Pounds; M J Bankowski; S W Belzer; J Carr; D Diorio; M S Forman; Y Joshi; D Hillyard; R L Hodinka; M N Nikiforova; C A Romain; J Stevenson; A Valsamakis; H H Balfour
Journal:  J Clin Microbiol       Date:  2007-11-07       Impact factor: 5.948

8.  Detection of cytomegalovirus (CMV) DNA in EDTA whole-blood samples: evaluation of the quantitative artus CMV LightCycler PCR kit in conjunction with automated sample preparation.

Authors:  Birgit D A Michelin; Ita Hadzisejdic; Michael Bozic; Maja Grahovac; Markus Hess; Blazenka Grahovac; Egon Marth; Harald H Kessler
Journal:  J Clin Microbiol       Date:  2008-02-13       Impact factor: 5.948

9.  Quantitative analysis of Epstein-Barr virus load by using a real-time PCR assay.

Authors:  H Kimura; M Morita; Y Yabuta; K Kuzushima; K Kato; S Kojima; T Matsuyama; T Morishima
Journal:  J Clin Microbiol       Date:  1999-01       Impact factor: 5.948

10.  Assessment of automated DNA extraction coupled with real-time PCR for measuring Epstein-Barr virus load in whole blood, peripheral mononuclear cells and plasma.

Authors:  Samira Fafi-Kremer; Karen Brengel-Pesce; Gérard Barguès; Marie-Josette Bourgeat; Odile Genoulaz; Jean-Marie Seigneurin; Patrice Morand
Journal:  J Clin Virol       Date:  2004-06       Impact factor: 3.168

View more
  4 in total

1.  Comparison of commercial extraction systems and PCR assays for quantification of Epstein-Barr virus DNA load in whole blood.

Authors:  Raphaële Germi; Julien Lupo; Touyana Semenova; Sylvie Larrat; Nelly Magnat; Laurence Grossi; Jean-Marie Seigneurin; Patrice Morand
Journal:  J Clin Microbiol       Date:  2012-01-11       Impact factor: 5.948

2.  Inter-laboratory assessment of different digital PCR platforms for quantification of human cytomegalovirus DNA.

Authors:  Jernej Pavšič; Alison Devonshire; Andrej Blejec; Carole A Foy; Fran Van Heuverswyn; Gerwyn M Jones; Heinz Schimmel; Jana Žel; Jim F Huggett; Nicholas Redshaw; Maria Karczmarczyk; Erkan Mozioğlu; Sema Akyürek; Müslüm Akgöz; Mojca Milavec
Journal:  Anal Bioanal Chem       Date:  2017-01-26       Impact factor: 4.142

3.  Automated Nucleic Acid Extraction Systems for Detecting Cytomegalovirus and Epstein-Barr Virus Using Real-Time PCR: A Comparison Study Between the QIAsymphony RGQ and QIAcube Systems.

Authors:  Hanah Kim; Mina Hur; Ji Young Kim; Hee Won Moon; Yeo Min Yun; Hyun Chan Cho
Journal:  Ann Lab Med       Date:  2017-03       Impact factor: 3.464

4.  Comparative evaluation of the QIAsymphony RGQ system with the easyMAG/R-gene combination for the quantitation of cytomegalovirus DNA load in whole blood.

Authors:  Sylvie Pillet; Thomas Bourlet; Bruno Pozzetto
Journal:  Virol J       Date:  2012-10-09       Impact factor: 4.099

  4 in total