Literature DB >> 21889353

Measurements of relative depth doses and Cerenkov light using a scintillating fiber-optic dosimeter with Co-60 radiotherapy source.

Kyoung Won Jang1, Wook Jae Yoo, Jinsoo Moon, Ki Tek Han, Jang-Yeon Park, Bongsoo Lee.   

Abstract

In this study, we fabricated a scintillating fiber-optic dosimeter, which consists of an organic scintillator and a plastic optical fiber, for radiotherapy dosimetry. To select an adequate kind and length of scintillator for γ-rays generated from a Co-60 source, scintillating light from various kinds and lengths of organic scintillators is measured. Using a scintillating fiber-optic dosimeter, the γ-rays generated from a Co-60 therapy unit are measured and relative doses are obtained according to the field size of the γ-ray beam and the depth in a water phantom. Also, Cerenkov light generated by the interactions of primary or secondary electrons and the plastic optical fiber is measured with different field sizes and depths of a water phantom using a background optical fiber.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21889353     DOI: 10.1016/j.apradiso.2011.08.005

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  5 in total

1.  In vivo localization of ⁹⁰Y and ¹⁷⁷Lu radioimmunoconjugates using Cerenkov luminescence imaging in a disseminated murine leukemia model.

Authors:  Ethan R Balkin; Aimee Kenoyer; Johnnie J Orozco; Alexandra Hernandez; Mazyar Shadman; Darrell R Fisher; Damian J Green; Mark D Hylarides; Oliver W Press; D Scott Wilbur; John M Pagel
Journal:  Cancer Res       Date:  2014-09-26       Impact factor: 12.701

2.  Real-time Cherenkov emission portal imaging during CyberKnife® radiotherapy.

Authors:  Yiannis Roussakis; Rongxiao Zhang; Geoff Heyes; Gareth Webster; Suzannah Mason; Stuart Green; Brian Pogue; Hamid Dehghani
Journal:  Phys Med Biol       Date:  2015-10-29       Impact factor: 3.609

3.  Integral T-shaped phantom-dosimeter system to measure transverse and longitudinal dose distributions simultaneously for stereotactic radiosurgery dosimetry.

Authors:  Wook Jae Yoo; Jinsoo Moon; Kyoung Won Jang; Ki-Tek Han; Sang Hun Shin; Dayeong Jeon; Jang-Yeon Park; Byung Gi Park; Bongsoo Lee
Journal:  Sensors (Basel)       Date:  2012-05-14       Impact factor: 3.576

4.  Development of a Small-Sized, Flexible, and Insertable Fiber-Optic Radiation Sensor for Gamma-Ray Spectroscopy.

Authors:  Wook Jae Yoo; Sang Hun Shin; Dong Eun Lee; Kyoung Won Jang; Seunghyun Cho; Bongsoo Lee
Journal:  Sensors (Basel)       Date:  2015-08-28       Impact factor: 3.576

5.  Feasibility of Ultra-Thin Fiber-Optic Dosimeters for Radiotherapy Dosimetry.

Authors:  Bongsoo Lee; Guwon Kwon; Sang Hun Shin; Jaeseok Kim; Wook Jae Yoo; Young Hoon Ji; Kyoung Won Jang
Journal:  Sensors (Basel)       Date:  2015-11-17       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.