OBJECTIVE: Evaluation of autonomic function responses is increasingly important for risk prediction and hemodynamic evaluation in the ambulant and perioperative setting, but requires a noninvasive arterial blood pressure measurement device. This study describes whether a novel noninvasive beat-to-beat arterial blood pressure measurement device (Nexfin HD) is able to reproducibly reflect autonomic function responses in healthy volunteers.
METHODS: Noninvasive beat-to-beat arterial blood pressure measurements (Nexfin HD) were performed in 20 healthy men of 22 ± 3 years. Measurements were performed during supine steady state, controlled breathing (0.125 Hz), passive leg raising, a controlled Valsalva maneuver, and a quick stand test. Finally, relative changes in pulse pressure during autonomic function testing and the test-retest reproducibility were determined.
RESULTS: Autonomic function tests induced beat-to-beat arterial blood pressure changes that were accurately monitored by the Nexfin device. The intraclass correlation coefficients for systolic and diastolic arterial blood pressure measurements during supine steady state were agreeable [0.91 (0.82-0.96) and 0.84 (0.69-0.93), respectively]. The reproducibility of blood pressure changes during controlled breathing, passive leg raising, and Valsalva maneuver averaged 0.92 (0.82-0.96), 0.76 (0.50-0.90), and 0.94 (0.89-0.97), respectively. The reproducibility of the pulse pressure variation (PPV) as calculated from controlled breathing-induced changes in the arterial blood pressure (13 ± 5%) was high [0.96 (0.93-0.98)].
CONCLUSION: This study shows that noninvasive beat-to-beat Nexfin HD arterial blood pressure measurements reproducibly reflect autonomic function responses in healthy volunteers.

Entities:  

Mesh:

Year:  2011        PMID: 21885960     DOI: 10.1097/MBP.0b013e32834b4431

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  7 in total

Review 1.  Non-invasive continuous blood pressure monitoring: a review of current applications.

Authors:  Elena Chung; Guo Chen; Brenton Alexander; Maxime Cannesson
Journal:  Front Med       Date:  2013-01-23       Impact factor: 4.592

2.  Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management.

Authors:  Guo Chen; Elena Chung; Lingzhong Meng; Brenton Alexander; Trung Vu; Joseph Rinehart; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2012-03-01       Impact factor: 2.502

Review 3.  Noninvasive continuous hemodynamic monitoring.

Authors:  Jasper Truijen; Johannes J van Lieshout; Wilbert A Wesselink; Berend E Westerhof
Journal:  J Clin Monit Comput       Date:  2012-06-14       Impact factor: 2.502

4.  Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.

Authors:  Jurre Stens; Jeroen Oeben; Ab A Van Dusseldorp; Christa Boer
Journal:  J Clin Monit Comput       Date:  2015-08-29       Impact factor: 2.502

5.  Comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit.

Authors:  G F N Berkelmans; S Kuipers; B E Westerhof; A M E Spoelstra-de Man; Y M Smulders
Journal:  J Clin Monit Comput       Date:  2017-07-07       Impact factor: 2.502

6.  Validation of the optical Aktiia bracelet in different body positions for the persistent monitoring of blood pressure.

Authors:  Josep Sola; Anna Vybornova; Sibylle Fallet; Erietta Polychronopoulou; Arlene Wurzner-Ghajarzadeh; Gregoire Wuerzner
Journal:  Sci Rep       Date:  2021-10-19       Impact factor: 4.379

7.  Comparison of the non-invasive Nexfin® monitor with conventional methods for the measurement of arterial blood pressure in moderate risk orthopaedic surgery patients.

Authors:  Felix Balzer; Marit Habicher; Michael Sander; Julian Sterr; Stephanie Scholz; Aarne Feldheiser; Michael Müller; Carsten Perka; Sascha Treskatsch
Journal:  J Int Med Res       Date:  2016-05-02       Impact factor: 1.671

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.