Literature DB >> 21871516

Evaluation of growth based rapid microbiological methods for sterility testing of vaccines and other biological products.

Seema Parveen1, Simleen Kaur, Selwyn A Wilson David, James L Kenney, William M McCormick, Rajesh K Gupta.   

Abstract

Most biological products, including vaccines, administered by the parenteral route are required to be tested for sterility at the final container and also at various stages during manufacture. The sterility testing method described in the Code of Federal Regulations (21 CFR 610.12) and the United States Pharmacopoeia (USP, Chapter <71>) is based on the observation of turbidity in liquid culture media due to growth of potential contaminants. We evaluated rapid microbiological methods (RMM) based on detection of growth 1) by adenosine triphosphate (ATP) bioluminescence technology (Rapid Milliflex(®) Detection System [RMDS]), and 2) by CO(2) monitoring technologies (BacT/Alert and the BACTEC systems), as alternate sterility methods. Microorganisms representing Gram negative, Gram positive, aerobic, anaerobic, spore forming, slow growing bacteria, yeast, and fungi were prepared in aliquots of Fluid A or a biological matrix (including inactivated influenza vaccines) to contain approximately 0.1, 1, 10 and 100 colony forming units (CFU) in an inoculum of 10 ml. These preparations were inoculated to the specific media required for the various methods: 1) fluid thioglycollate medium (FTM) and tryptic soy broth (TSB) of the compendial sterility method (both membrane filtration and direct inoculation); 2) tryptic soy agar (TSA), Sabouraud dextrose agar (SDA) and Schaedler blood agar (SBA) of the RMDS; 3) iAST and iNST media of the BacT/Alert system and 4) Standard 10 Aerobic/F and Standard Anaerobic/F media of the BACTEC system. RMDS was significantly more sensitive in detecting various microorganisms at 0.1CFU than the compendial methods (p<0.05), whereas the compendial membrane filtration method was significantly more sensitive than the BACTEC and BacT/Alert methods (p<0.05). RMDS detected all microorganisms significantly faster than the compendial method (p<0.05). BacT/Alert and BACTEC methods detected most microorganisms significantly faster than the compendial method (p<0.05), but took almost the same time to detect the slow growing microorganism P. acnes, compared to the compendial method. RMDS using SBA detected all test microorganisms in the presence of a matrix containing preservative 0.01% thimerosal, whereas the BacT/Alert and BACTEC systems did not consistently detect all the test microorganisms in the presence of 0.01% thimerosal. RMDS was compatible with inactivated influenza vaccines and aluminum phosphate or aluminum hydroxide adjuvants at up to 8 mg/ml without any interference in bioluminescence. RMDS was shown to be acceptable as an alternate sterility method taking 5 days as compared to the 14 days required of the compendial method. Isolation of microorganisms from the RMDS was accomplished by re-incubation of membranes with fresh SBA medium and microbial identification was confirmed using the MicroSEQ Identification System. BacT/Alert and BACTEC systems may be applicable as alternate methods to the compendial direct inoculation sterility method for products that do not contain preservatives or anti-microbial agents. Published by Elsevier Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21871516     DOI: 10.1016/j.vaccine.2011.08.055

Source DB:  PubMed          Journal:  Vaccine        ISSN: 0264-410X            Impact factor:   3.641


  12 in total

1.  Microbial growth in neonatal intravenous fat emulsion administered over 12 versus 24 hours.

Authors:  Bethany M Dedonato; Lisa I Bickford; Ryan J Gates
Journal:  J Pediatr Pharmacol Ther       Date:  2013-10

2.  Standard requirement of a microbiological quality control program for the manufacture of human mesenchymal stem cells for clinical use.

Authors:  Patricia Gálvez; Beatriz Clares; Maria Bermejo; Abdelkrim Hmadcha; Bernat Soria
Journal:  Stem Cells Dev       Date:  2014-02-20       Impact factor: 3.272

Review 3.  Sterility Testing for Cellular Therapies: What Is the Role of the Clinical Microbiology Laboratory?

Authors:  James E T Gebo; Anna F Lau
Journal:  J Clin Microbiol       Date:  2020-06-24       Impact factor: 5.948

4.  Comprehensive Evaluation of Compendial USP<71>, BacT/Alert Dual-T, and Bactec FX for Detection of Product Sterility Testing Contaminants.

Authors:  Matthew R England; Frida Stock; James E T Gebo; Karen M Frank; Anna F Lau
Journal:  J Clin Microbiol       Date:  2019-01-30       Impact factor: 5.948

5.  LONG-TERM PHYSICAL STABILITY, STERILITY, AND ANTI-VEGF BIOACTIVITY OF REPACKAGED BEVACIZUMAB IN 2-ML GLASS VIALS.

Authors:  Jan S Peterson; Kenneth Rockwell; Ingrid U Scott; Michael S Ip; Paul C VanVeldhuisen; Barbara A Blodi
Journal:  Retina       Date:  2019-09       Impact factor: 4.256

6.  Microbiological Control of Cellular Products: The Relevance of the Cellular Matrix, Incubation Temperature, and Atmosphere for the Detection Performance of Automated Culture Systems.

Authors:  Susanne-Katharina Günther; Celina Geiss; Stefan J Kaiser; Nico T Mutters; Frank Günther
Journal:  Transfus Med Hemother       Date:  2019-10-22       Impact factor: 3.747

Review 7.  Scalable Manufacturing of CAR T cells for Cancer Immunotherapy.

Authors:  Mohamed Abou-El-Enein; Magdi Elsallab; Gerhard Bauer; Barbara Savoldo; Steven A Feldman; Andrew D Fesnak; Helen E Heslop; Peter Marks; Brian G Till
Journal:  Blood Cancer Discov       Date:  2021-08-03

8.  Supercritical carbon dioxide-based sterilization of decellularized heart valves.

Authors:  Ryan S Hennessy; Soumen Jana; Brandon J Tefft; Meghana R Helder; Melissa D Young; Rebecca R Hennessy; Nicholas J Stoyles; Amir Lerman
Journal:  JACC Basic Transl Sci       Date:  2017-02

9.  Performance Survey and Comparison Between Rapid Sterility Testing Method and Pharmacopoeia Sterility Test.

Authors:  Adriana Bugno; Deborah Pita Sanches Saes; Adriana Aparecida Buzzo Almodovar; Kamal Dua; Rajendra Awasthi; Daniela Dal Molim Ghisleni; Marici Tiomi Hirota; Wesley Anderson de Oliveira; Terezinha de Jesus Andreoli Pinto
Journal:  J Pharm Innov       Date:  2017-12-05       Impact factor: 2.750

10.  Application of the BacT/ALERTR 3D system for sterility testing of injectable products.

Authors:  Adriana Bugno; Rodolfo Santos Lira; Wesley Anderson Oliveira; Adriana Aparecida Buzzo Almodovar; Deborah Pita Sanches Saes; Terezinha de Jesus Andreoli Pinto
Journal:  Braz J Microbiol       Date:  2015-07-01       Impact factor: 2.476

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.