Literature DB >> 21870318

Measurement of the Optic Nerve Sheath Diameter in Children: Comparison Between Transbulbar Sonography and Magnetic Resonance Imaging.

M Steinborn1, J Fiegler1, K Ruedisser1, A Hapfelmeier2, C Denne3, E Macdonald1, H Hahn1.   

Abstract

PURPOSE: To evaluate the accuracy of measurements of the optic nerve sheath diameter (ONSD) in children by comparing transbulbar sonography with magnetic resonance imaging (MRI).
MATERIALS AND METHODS: 65 children (age: 3 mo- 17y; mean age: 11.3y) underwent MR imaging of the brain including a heavily T 2-w sequence of the orbit and transbulbar sonography using a 17 MHz linear array transducer. Measurements of the ONSD were performed retrospectively by two experienced readers and all images were evaluated regarding the image quality. Bland-Altman Plots were produced to assess the accuracy of measurements. The correlation between readers and between MR imaging and transbulbar sonography was calculated by the concordance correlation coefficient (CCC).
RESULTS: Overall the mean values of the ONSD for MRI (5.86 ± 0.66 mm) and transbulbar sonography (5.86 ± 0.71 mm) were identical. There was a high correlation between readers for measurements of the ONSD both for transbulbar sonography (CCC = 0.93) as well as for MRI (CCC = 0.9). Comparing the measurement values between transbulbar sonography and MRI, the correlation of ONSD values was good to moderate with a high dependency on image quality (CCC [0.31, 0.68]).
CONCLUSION: We were able to demonstrate that the ONSD values of transbulbar sonography in children correlate well with MRI if the relevant anatomic structures are depicted and the measuring points are set correctly. Based on the findings of our study, it seems necessary to define normal and cut-off values for the ONSD in children again to finally assess the clinical relevance of the ONSD as a noninvasive parameter for the evaluation of intracranial pressure. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Year:  2011        PMID: 21870318     DOI: 10.1055/s-0031-1273491

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  13 in total

1.  Diagnostic value of neuro-ophthalmological signs in cases of Chiari I malformation.

Authors:  Inessa Bekerman; Tal Sigal; Itzhak Kimiagar; Zina Evy Almer; Michael Vaiman
Journal:  Childs Nerv Syst       Date:  2016-11-08       Impact factor: 1.475

Review 2.  Non-invasive detection of intracranial pressure related to the optic nerve.

Authors:  Jian Li; Chao Wan
Journal:  Quant Imaging Med Surg       Date:  2021-06

3.  [Sonographic study of the diameter of the sheath of the optic nerve in healthy black African children].

Authors:  Kofi-Mensa Savi de Tové; Olivier Biaou; Julien Didier Adedemy; Olatoundji Holden Fatigba; Patricia Yèkpè; Vicentia Boco; Augustin Karl Agossou-Voyeme
Journal:  Pan Afr Med J       Date:  2014-11-15

Review 4.  Neuromuscular ultrasound of cranial nerves.

Authors:  Eman A Tawfik; Francis O Walker; Michael S Cartwright
Journal:  J Clin Neurol       Date:  2015-04       Impact factor: 3.077

5.  Estimating the accuracy of optic nerve sheath diameter measurement using a pocket-sized, handheld ultrasound on a simulation model.

Authors:  Garrett G R J Johnson; Frederick A Zeiler; Bertram Unger; Gregory Hansen; Dimitrios Karakitsos; Lawrence M Gillman
Journal:  Crit Ultrasound J       Date:  2016-11-10

6.  Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter.

Authors:  Li-Juan Wang; Yan Yao; Liang-Shu Feng; Yu-Zhi Wang; Nan-Nan Zheng; Jia-Chun Feng; Ying-Qi Xing
Journal:  Sci Rep       Date:  2017-02-07       Impact factor: 4.379

Review 7.  Optic Nerve and Cerebral Edema in the Course of Diabetic Ketoacidosis.

Authors:  Łukasz Szmygel; Wojciech Kosiak; Katarzyna Zorena; Małgorzata Myśliwiec
Journal:  Curr Neuropharmacol       Date:  2016       Impact factor: 7.363

8.  Correlation of measurement of optic nerve sheath diameter using ultrasound with magnetic resonance imaging.

Authors:  Chetan G Shirodkar; Kartik Munta; S Manimala Rao; M Uma Mahesh
Journal:  Indian J Crit Care Med       Date:  2015-08

9.  Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging.

Authors:  Jochen Bäuerle; Florian Schuchardt; Laure Schroeder; Karl Egger; Matthias Weigel; Andreas Harloff
Journal:  BMC Neurol       Date:  2013-12-01       Impact factor: 2.474

10.  Comparison of Ocular Ultrasonography and Magnetic Resonance Imaging for Detection of Increased Intracranial Pressure.

Authors:  David F Patterson; Mai-Lan Ho; Jacqueline A Leavitt; Nathan J Smischney; Sara E Hocker; Eelco F Wijdicks; David O Hodge; John Jing-Wei Chen
Journal:  Front Neurol       Date:  2018-04-24       Impact factor: 4.003

View more