Literature DB >> 21862378

A survey and comparative study on the instruments for glaucoma detection.

Teik-Cheng Lim1, Subhagata Chattopadhyay, U Rajendra Acharya.   

Abstract

Glaucoma is one of the leading causes of irreversible blindness worldwide. It has been proposed that the intraocular pressure is a causative factor in the development of glaucoma, which is an optic neuropathy. This paper surveys the use of tonometers, gonioscopes, optical coherence tomographs, scanning laser polarimeters, scanning laser ophthalmoscopes (also known as scanning laser tomographs) and corneal pachymeters for the diagnosis and management of glaucoma. The working mechanisms as well as the comparative advantages and disadvantages of each of these instruments are presented.
Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21862378     DOI: 10.1016/j.medengphy.2011.07.030

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  8 in total

Review 1.  Adaptive optics retinal imaging--clinical opportunities and challenges.

Authors:  Joseph Carroll; David B Kay; Drew Scoles; Alfredo Dubra; Marco Lombardo
Journal:  Curr Eye Res       Date:  2013-04-26       Impact factor: 2.424

2.  Registration of adaptive optics corrected retinal nerve fiber layer (RNFL) images.

Authors:  Gomathy Ramaswamy; Marco Lombardo; Nicholas Devaney
Journal:  Biomed Opt Express       Date:  2014-05-22       Impact factor: 3.732

Review 3.  Tonometers-which one should I use?

Authors:  Kanza Aziz; David S Friedman
Journal:  Eye (Lond)       Date:  2018-02-19       Impact factor: 3.775

Review 4.  Adaptive optics optical coherence tomography in glaucoma.

Authors:  Zachary M Dong; Gadi Wollstein; Bo Wang; Joel S Schuman
Journal:  Prog Retin Eye Res       Date:  2016-12-01       Impact factor: 21.198

5.  Classification of Glaucoma Stages Using Image Empirical Mode Decomposition from Fundus Images.

Authors:  Deepak Parashar; Dheraj Kumar Agrawal
Journal:  J Digit Imaging       Date:  2022-05-17       Impact factor: 4.903

6.  Characterization of Corneal Biomechanical Properties and Determination of Natural Intraocular Pressure Using CID-GAT.

Authors:  Shu-Hao Lu; I T Chong; Stanley Y Y Leung; David C C Lam
Journal:  Transl Vis Sci Technol       Date:  2019-09-11       Impact factor: 3.283

Review 7.  Adaptive optics technology for high-resolution retinal imaging.

Authors:  Marco Lombardo; Sebastiano Serrao; Nicholas Devaney; Mariacristina Parravano; Giuseppe Lombardo
Journal:  Sensors (Basel)       Date:  2012-12-27       Impact factor: 3.576

8.  Mean curvature and texture constrained composite weighted random walk algorithm for optic disc segmentation towards glaucoma screening.

Authors:  Rashmi Panda; N B Puhan; Ganapati Panda
Journal:  Healthc Technol Lett       Date:  2018-01-05
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.