Literature DB >> 21861961

Efficacy of the RADPAD protective drape during real world complex percutaneous coronary intervention procedures.

John C Murphy1, Karen Darragh, Simon J Walsh, Colm G Hanratty.   

Abstract

The RADPAD is a lead-free surgical drape containing bismuth and barium that has been demonstrated to reduce scatter radiation exposure to primary operators during fluoroscopic procedures. It is not known to what degree the RADPAD reduces radiation exposure in operators who perform highly complex percutaneous coronary intervention (PCI) requiring prolonged fluoroscopic screening times. Sixty consecutive patients due to undergo elective complex PCI involving rotational atherectomy, multivessel PCI, or chronic total occlusions were randomized in a 1:1 pattern to have their procedures performed with and without the RADPAD drape in situ. Dosimetry was performed on the left arm of the primary operator. There were 40 cases of chronic total occlusion, including 28 with contralateral injections; 15 cases involving rotational atherectomy; and 5 cases of multivessel PCI. There was no significant difference in screening times or dose-area products between the 2 patient groups. Primary operator radiation dose relative to screening time (RADPAD: slope = 1.44, R² = 0.25; no RADPAD: slope = 4.60, R² = 0.26; analysis of covariance F = 4.81, p = 0.032) and dose-area product (RADPAD: slope = 0.003, R² = 0.26; no RADPAD: slope = 0.011, R² = 0.52; analysis of covariance F = 12.54, p = 0.008) was significantly smaller in the RADPAD cohort compared to the no-RADPAD group. In conclusion, the RADPAD significantly reduces radiation exposure to primary operators during prolonged, complex PCI cases.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21861961     DOI: 10.1016/j.amjcard.2011.06.061

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  11 in total

1.  A double-blind, randomized, sham-controlled trial of the effect of a radiation-attenuating drape on radiation exposure to endoscopy staff during ERCP.

Authors:  Thiruvengadam Muniraj; Harry R Aslanian; Loren Laine; James Farrell; Maria M Ciarleglio; Yanhong Deng; Henry Ho; Priya A Jamidar
Journal:  Am J Gastroenterol       Date:  2015-03-31       Impact factor: 10.864

2.  The Efficacy of Shielding Systems for Reducing Operator Exposure during Neurointerventional Procedures: A Real-World Prospective Study.

Authors:  T R Miller; J Zhuo; G Jindal; R Shivashankar; N Beaty; D Gandhi
Journal:  AJNR Am J Neuroradiol       Date:  2016-12-22       Impact factor: 3.825

3.  Is lead shielding of patients necessary during fluoroscopic procedures? A study based on kyphoplasty.

Authors:  Joshua R Smith; Rebecca M Marsh; Michael S Silosky
Journal:  Skeletal Radiol       Date:  2017-08-18       Impact factor: 2.199

Review 4.  Prevention of Contrast and Radiation Injury During Coronary Angiography and Percutaneous Coronary Intervention.

Authors:  Arash Ehteshami Afshar; Puja B Parikh
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-03-22

5.  Radiation Exposure During Transcatheter Valve Replacement: What Cardiac Surgeons Need to Know.

Authors:  Alejandro Aquino; Ali J Khiabani; Matthew C Henn; Alan Zajarias; Spencer J Melby; Marc Sintek; John Lasala; Puja Kachroo; Eric Novak; Hersh S Maniar
Journal:  Ann Thorac Surg       Date:  2019-07-06       Impact factor: 4.330

6.  Efficacy of RADPAD protective drape during coronary angiography.

Authors:  B Kherad; T Jerichow; F Blaschke; M Noutsias; B Pieske; C Tschöpe; F Krackhardt
Journal:  Herz       Date:  2017-04-07       Impact factor: 1.443

7.  Minimizing scattered radiation dose in cardiac catheterization laboratory during interventional procedures using lead free drape - MILD study.

Authors:  Keshavamurthy Ganapathy Bhat; Vivek Singh Guleria; Manish Singla; Vijay Bohra; Ratheesh Kumar J; Prashant Bharadwaj; Rajat Datta; Pradeep Kumar Hasija
Journal:  Indian Heart J       Date:  2022-04-12

8.  A novel radiation protection device based on tungsten functional paper for application in interventional radiology.

Authors:  Hajime Monzen; Mikoto Tamura; Kohei Shimomura; Yuichi Onishi; Shinichi Nakayama; Takahiro Fujimoto; Kenji Matsumoto; Kohei Hanaoka; Takeshi Kamomae
Journal:  J Appl Clin Med Phys       Date:  2017-04-19       Impact factor: 2.102

9.  Effectiveness of additional X-ray protection devices in reducing Scattered radiation in radial interventions: protocol of the ESPRESSO randomised trial.

Authors:  Remzi Anadol; Moritz Brandt; Nico Merz; Maike Knorr; Majid Ahoopai; Martin Geyer; Damian Krompiec; Phillip Wenzel; Thomas Münzel; Tommaso Gori
Journal:  BMJ Open       Date:  2019-07-03       Impact factor: 2.692

Review 10.  Radiation protection for the interventional cardiologist: Practical approach and innovations.

Authors:  Alejandro Gutierrez-Barrios; Dolores Cañadas-Pruaño; Inmaculada Noval-Morillas; Livia Gheorghe; Ricardo Zayas-Rueda; German Calle-Perez
Journal:  World J Cardiol       Date:  2022-01-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.