Literature DB >> 21855409

Real-time multiplex PCR for simultaneous detection of Campylobacter jejuni, Salmonella, Shigella and Yersinia species in fecal samples.

Dorothea Wiemer1, Ulrike Loderstaedt, Hinrik von Wulffen, Simone Priesnitz, Marcellus Fischer, Egbert Tannich, Ralf Matthias Hagen.   

Abstract

Diarrheal diseases due to notifiable bacterial infections require rapid diagnosis of the causative pathogens. To facilitate detection, a real-time multiplex PCR was developed that identifies common diarrhea-causing bacteria in fecal samples. On the basis of published sequence data, sets of primers and probes were designed that were specific for Campylobacter jejuni, Salmonella, Shigella/enteroinvasive Escherichia coli EIEC, and Yersinia species, suitable for use in a one-tube PCR assay. The assay was assessed using a list of 137 well-defined intestinal bacterial strains or isolates. Furthermore, 393 routine clinical stool samples were analyzed, and the results of real-time multiplex PCR were compared with those obtained by established microbiological methods. The PCR yielded results within 3h including DNA purification. No false-positive signals or cross-reactions were observed. The analytical sensitivity was 10(3)cfumL(-1) for Campylobacter jejuni, 10(4)cfumL(-1) for Salmonella, and 10(5)cfumL(-1) for Shigella/EIEC and Yersinia, respectively. Compared with culture, PCR detected 79 out of 81 Campylobacter jejuni (97.5%), 71 out of 74 Salmonella (96%), 8 out of 8 Shigella (100%), and 10 out of 10 Yersinia-positive (100%) clinical samples. In culture-negative samples (n=192), PCR additionally detected 2 Shigella, 1 Salmonella, and 5 Campylobacter jejuni infections. Thus, the new real-time multiplex PCR provides reliable results within a short time and might be useful as an additional diagnostic tool whenever time is important in the diagnosis of enteropathogenic bacteria.
Copyright © 2011 Elsevier GmbH. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21855409     DOI: 10.1016/j.ijmm.2011.06.001

Source DB:  PubMed          Journal:  Int J Med Microbiol        ISSN: 1438-4221            Impact factor:   3.473


  23 in total

1.  Multiplex real-time PCR for detection of Campylobacter, Salmonella, and Shigella.

Authors:  F Barletta; E H Mercado; A Lluque; J Ruiz; T G Cleary; T J Ochoa
Journal:  J Clin Microbiol       Date:  2013-06-12       Impact factor: 5.948

2.  Real-time PCR threshold cycle cutoffs help to identify agents causing acute childhood diarrhea in Zanzibar.

Authors:  Kristina Elfving; Maria Andersson; Mwinyi I Msellem; Christina Welinder-Olsson; Max Petzold; Anders Björkman; Birger Trollfors; Andreas Mårtensson; Magnus Lindh
Journal:  J Clin Microbiol       Date:  2014-01-08       Impact factor: 5.948

3.  Comparison of an automated nucleic acid extraction system with the column-based procedure.

Authors:  Hagen Frickmann; Rebecca Hinz; Ralf Matthias Hagen
Journal:  Eur J Microbiol Immunol (Bp)       Date:  2015-03-26

4.  Pentaplex PCR assay for detection of hemorrhagic bacteria from stool samples.

Authors:  Hassanain Al-Talib; Baha Latif; Zaini Mohd-Zain
Journal:  J Clin Microbiol       Date:  2014-06-23       Impact factor: 5.948

Review 5.  Campylobacter bacteremia: a rare and under-reported event?

Authors:  R Louwen; P van Baarlen; A H M van Vliet; A van Belkum; J P Hays; H P Endtz
Journal:  Eur J Microbiol Immunol (Bp)       Date:  2012-03-17

6.  Impact of Culture-Independent Diagnostic Testing on Recovery of Enteric Bacterial Infections.

Authors:  Aamer Imdad; Fiona Retzer; Linda S Thomas; Marcy McMillian; Katie Garman; Peter F Rebeiro; Stephen A Deppen; John R Dunn; Amy M Woron
Journal:  Clin Infect Dis       Date:  2018-06-01       Impact factor: 9.079

7.  Evaluation of a real-time multiplex PCR for the simultaneous detection of Campylobacter jejuni, Salmonella spp., Shigella spp./EIEC, and Yersinia enterocolitica in fecal samples.

Authors:  P Van Lint; E De Witte; H De Henau; A De Muynck; L Verstraeten; B Van Herendael; S Weekx
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2014-10-19       Impact factor: 3.267

8.  Development and application of a real-time polymerase chain reaction method for Campylobacter jejuni detection.

Authors:  Mao-Jun Zhang; Bo Qiao; Xue-Bin Xu; Jian-Zhong Zhang
Journal:  World J Gastroenterol       Date:  2013-05-28       Impact factor: 5.742

9.  Multiplex T-RFLP allows for increased target number and specificity: detection of Salmonella enterica and six species of Listeria in a single test.

Authors:  Geoffrey N Elliott; Nadine Thomas; Marion Macrae; Colin D Campbell; Iain D Ogden; Brajesh K Singh
Journal:  PLoS One       Date:  2012-08-24       Impact factor: 3.240

10.  Simultaneous detection of viral and bacterial enteric pathogens using the Seeplex® Diarrhea ACE detection system.

Authors:  L J Coupland; I McElarney; E Meader; K Cowley; L Alcock; J Naunton; J Gray
Journal:  Epidemiol Infect       Date:  2012-12-05       Impact factor: 4.434

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.