Literature DB >> 21853456

Augmentation of peri-implant bone improves implant stability: quantification using simulated bone loss.

Andreas J Wirth1, Ralph Müller, G Harry van Lenthe.   

Abstract

Low bone quality, such as induced by osteoporosis, is considered a main factor leading to failure of fracture fixations. Peri-implant bone augmentation has been proposed as a means of reducing failure rates in osteoporotic bone by improving implant stability. The beneficial effects of pharmacological augmentation of bone in the immediate vicinity of the implant have been demonstrated. Yet, a quantitative understanding of the role of peri-implant bone in implant stability is lacking. Therefore, the aim of our study was to quantify the effects of bone loss and peri-implant bone augmentation on implant stability using image-based finite element analyses. Using a validated model, we simulated how osteoporotic bone loss would affect implant stability in human humeral heads. We also quantified how augmentation of peri-implant bone can enhance implant stability. Our simulations revealed that a 30% reduction in bone mass led to a 50% decrease in implant stability. We also found that peri-implant bone augmentation increased implant stability and that the efficiency of bone augmentation decreased with increasing peri-implant distance. These findings highlight the strong effect that bone loss has on implant fixation and the potential of peri-implant bone augmentation for improving implant anchorage in low quality bone.
Copyright © 2011 Orthopaedic Research Society.

Entities:  

Mesh:

Year:  2011        PMID: 21853456     DOI: 10.1002/jor.21532

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  5 in total

1.  Intermittent PTH administration and mechanical loading are anabolic for periprosthetic cancellous bone.

Authors:  Matthew J Grosso; Hayden-William Courtland; Xu Yang; James P Sutherland; Kirsten Stoner; Joseph Nguyen; Anna Fahlgren; F Patrick Ross; Marjolein C H van der Meulen; Mathias P Bostrom
Journal:  J Orthop Res       Date:  2014-11-18       Impact factor: 3.494

2.  Single-dose local simvastatin injection improves implant fixation via increased angiogenesis and bone formation in an ovariectomized rat model.

Authors:  Jie Tan; Ning Yang; Xin Fu; Yueyi Cui; Qi Guo; Teng Ma; Xiaoxue Yin; Huijie Leng; Chunli Song
Journal:  Med Sci Monit       Date:  2015-05-18

Review 3.  The Applications of Finite Element Analysis in Proximal Humeral Fractures.

Authors:  Yongyu Ye; Wei You; Weimin Zhu; Jiaming Cui; Kang Chen; Daping Wang
Journal:  Comput Math Methods Med       Date:  2017-09-10       Impact factor: 2.238

4.  Trabecular deformations during screw pull-out: a micro-CT study of lapine bone.

Authors:  Thomas Joffre; Per Isaksson; Philip Procter; Cecilia Persson
Journal:  Biomech Model Mechanobiol       Date:  2017-03-06

Review 5.  Finite Element Analysis of Fracture Fixation.

Authors:  Gregory S Lewis; Dominic Mischler; Hwabok Wee; J Spence Reid; Peter Varga
Journal:  Curr Osteoporos Rep       Date:  2021-06-29       Impact factor: 5.163

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.