Literature DB >> 21853192

SU8 diaphragm micropump with monolithically integrated cantilever check valves.

Aitor Ezkerra1, Luis José Fernández, Kepa Mayora, Jesús Miguel Ruano-López.   

Abstract

This paper presents a SU8 unidirectional diaphragm micropump with embedded out-of-plane cantilever check valves. The device represents a reliable and low-cost solution for integration of microfluidic control in lab-on-a-chip devices. Its planar architecture allows monolithic definition of its components in a single step and potential integration with previously reported PCR, electrophoresis and flow-sensing SU8 microdevices. Pneumatic actuation is applied on a PDMS diaphragm, which is bonded to the SU8 body at wafer level, further enhancing its integration and mass production capabilities. The cantilever check valves move synchronously with the diaphragm, feature fast response (10ms), low dead volume (86nl) and a 94% flow blockage up to 300kPa. The micropump achieves a maximum flow rate of 177 μl min(-1) at 6 Hz and 200 kPa with an effective area of 10 mm(2). The device is reliable, self-priming and tolerant to particles and big bubbles. To the knowledge of the authors, this is the first micropump in SU8 with monolithically integrated cantilever check valves.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21853192     DOI: 10.1039/c1lc20324j

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  5 in total

1.  High-performance microfluidic rectifier based on sudden expansion channel with embedded block structure.

Authors:  Chien-Hsiung Tsai; Che-Hsin Lin; Lung-Ming Fu; Hui-Chun Chen
Journal:  Biomicrofluidics       Date:  2012-04-13       Impact factor: 2.800

Review 2.  Advances in microfluidic materials, functions, integration, and applications.

Authors:  Pamela N Nge; Chad I Rogers; Adam T Woolley
Journal:  Chem Rev       Date:  2013-02-14       Impact factor: 60.622

3.  Microfluidic rectifier based on poly(dimethylsiloxane) membrane and its application to a micropump.

Authors:  Yao-Nan Wang; Chien-Hsiung Tsai; Lung-Ming Fu; Lung-Kai Lin Liou
Journal:  Biomicrofluidics       Date:  2013-08-14       Impact factor: 2.800

4.  A passive Stokes flow rectifier for Newtonian fluids.

Authors:  Aryan Mehboudi; Junghoon Yeom
Journal:  Sci Rep       Date:  2021-05-13       Impact factor: 4.996

5.  A microfluidic pump/valve inspired by xylem embolism and transpiration in plants.

Authors:  Li Jingmin; Liu Chong; Xu Zheng; Zhang Kaiping; Ke Xue; Wang Liding
Journal:  PLoS One       Date:  2012-11-29       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.