Literature DB >> 21849075

Legionella pneumophila serogroup 3 pneumonia in a patient with low-grade 4 non-Hodgkin lymphoma: a case report.

Antonella Mencacci1, Cristina Corbucci, Alessio Castellani, Paolo Furno, Francesco Bistoni, Anna Vecchiarelli.   

Abstract

INTRODUCTION: Nosocomial legionellosis has generally been described in immunodepressed patients, but Legionella pneumophila serogroup 3 has rarely been identified as the causative agent. CASE
PRESENTATION: We report the case of nosocomial L. pneumophila serogroup 3 pneumonia in a 70-year-old Caucasian man with non-Hodgkin lymphoma. Diagnosis was carried out by culture and real-time polymerase chain reaction of bronchoalveolar lavage fluid. The results of a urinary antigen test were negative. A hospital environmental investigation revealed that the hospital water system was highly colonized by L. pneumophila serogroups 3, 4, and 8. The hospital team involved in the prevention of infections was informed, long-term control measures to reduce the environmental bacterial load were adopted, and clinical monitoring of legionellosis occurrence in high-risk patients was performed. No further cases of Legionella pneumonia have been observed so far.
CONCLUSIONS: In this report, we describe a case of legionellosis caused by L. pneumophila serogroup 3, which is not usually a causative agent of nosocomial infection. Our research confirms the importance of carrying out cultures of respiratory secretions to diagnose legionellosis and highlights the limited value of the urinary antigen test for hospital infections, especially in immunocompromised patients. It also indicates that, to reduce the bacterial load and prevent nosocomial legionellosis, appropriate control measures should be implemented with systematic monitoring of hospital water systems.

Entities:  

Year:  2011        PMID: 21849075      PMCID: PMC3177915          DOI: 10.1186/1752-1947-5-387

Source DB:  PubMed          Journal:  J Med Case Rep        ISSN: 1752-1947


  13 in total

1.  Pan-European study on culture-proven Legionnaires' disease: distribution of Legionella pneumophila serogroups and monoclonal subgroups.

Authors:  J H Helbig; S Bernander; M Castellani Pastoris; J Etienne; V Gaia; S Lauwers; D Lindsay; P C Lück; T Marques; S Mentula; M F Peeters; C Pelaz; M Struelens; S A Uldum; G Wewalka; T G Harrison
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2002-10-18       Impact factor: 3.267

2.  Respiratory fluoroquinolones: differences in the details.

Authors:  L A Mandell; P B Iannini; G S Tillotson
Journal:  Clin Infect Dis       Date:  2004-05-01       Impact factor: 9.079

3.  Comparison of three molecular methods used for subtyping of Legionella pneumophila strains isolated during an epidemic of Legionellosis in Rome.

Authors:  M Scaturro; M Losardo; G De Ponte; M L Ricci
Journal:  J Clin Microbiol       Date:  2005-10       Impact factor: 5.948

4.  Hospital characteristics associated with colonization of water systems by Legionella and risk of nosocomial legionnaires' disease: a cohort study of 15 hospitals.

Authors:  J L Kool; D Bergmire-Sweat; J C Butler; E W Brown; D J Peabody; D S Massi; J C Carpenter; J M Pruckler; R F Benson; B S Fields
Journal:  Infect Control Hosp Epidemiol       Date:  1999-12       Impact factor: 3.254

5.  Point-of-care controls for nosocomial legionellosis combined with chlorine dioxide potable water decontamination: a two-year survey at a Welsh teaching hospital.

Authors:  I K Hosein; D W Hill; T Y Tan; E G Butchart; K Wilson; G Finlay; S Burge; C D Ribeiro
Journal:  J Hosp Infect       Date:  2005-10       Impact factor: 3.926

6.  Rapid diagnosis of Legionella pneumophila serogroup 1 infection with the Binax enzyme immunoassay urinary antigen test.

Authors:  D Kazandjian; R Chiew; G L Gilbert
Journal:  J Clin Microbiol       Date:  1997-04       Impact factor: 5.948

7.  Monitoring of hospital water supplies for Legionella.

Authors:  W K Liu; D E Healing; J T Yeomans; T S Elliott
Journal:  J Hosp Infect       Date:  1993-05       Impact factor: 3.926

Review 8.  Nosocomial legionellosis: prevention and management.

Authors:  Anna S Levin
Journal:  Expert Rev Anti Infect Ther       Date:  2009-02       Impact factor: 5.091

Review 9.  Legionella and Legionnaires' disease: 25 years of investigation.

Authors:  Barry S Fields; Robert F Benson; Richard E Besser
Journal:  Clin Microbiol Rev       Date:  2002-07       Impact factor: 26.132

10.  Nosocomial outbreak of Legionella pneumophila serogroup 3 pneumonia in a new bone marrow transplant unit: evaluation, treatment and control.

Authors:  I Oren; T Zuckerman; I Avivi; R Finkelstein; M Yigla; J M Rowe
Journal:  Bone Marrow Transplant       Date:  2002-08       Impact factor: 5.483

View more
  2 in total

1.  Epidemiological Investigation of Legionella pneumophila Serogroup 2 to 14 Isolates from Water Samples by Amplified Fragment Length Polymorphism and Sequence-Based Typing and Detection of Virulence Traits.

Authors:  Anna Katsiaflaka; Spyros Pournaras; Ioulia Kristo; Varvara A Mouchtouri; Maria Kyritsi; Emmanuel Velonakis; Alkiviadis C Vatopoulos; Christos Hadjichristodoulou
Journal:  Appl Environ Microbiol       Date:  2016-09-30       Impact factor: 4.792

2.  Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities.

Authors:  Qadreyah A Al-Matawah; Sameer F Al-Zenki; Jafer A Qasem; Tahani E Al-Waalan; Ahmed H Ben Heji
Journal:  J Pathog       Date:  2012-07-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.