Literature DB >> 21847915

[Determination of chemical oxygen demand in water using near infrared transmission and UV absorbance method].

Guo-Qing Wu1, Wei-Hong Bi, Jia-Ming Lui, Guang-Wei Fu.   

Abstract

Chemical oxygen demand (COD) is a synthetical indicator which represents the degree of organic pollution in water. The near-infrared (NIR) transmission and the UV absorbance method based on photoelectric detection technology and spectroscopy analysis have some advantages such as high precision, speed, non-contact, no secondary pollution etc compared to conventional wet chemical method. The NIR transmission spectra and UV absorbance spectra of standard solution configured with phthalate hydrogen potassium were collected respectively by MPA FTIR spectrometer (Bruker Optics Inc.) made in Germany and AvaSpec-2048-2 UV spectrometer (Avantes Inc.) made in Netherlands. After different pretreatment to the spectra, COD quantitative analysis model was established using partial least squares regression (PLS) and linear regression. The statistical analysis of COD quantitative model was implemented, and the result showed that UV absorbance method had a higher relevance but lower forecast accuracy and precision than NIR transmission method.

Entities:  

Year:  2011        PMID: 21847915

Source DB:  PubMed          Journal:  Guang Pu Xue Yu Guang Pu Fen Xi        ISSN: 1000-0593            Impact factor:   0.589


  4 in total

1.  Investigating hydrochemistry of groundwater in Indo-Gangetic alluvial plain using multivariate chemometric approaches.

Authors:  Kunwar P Singh; Shikha Gupta; Premanjali Rai
Journal:  Environ Sci Pollut Res Int       Date:  2014-01-25       Impact factor: 4.223

2.  Phytoremediation processes of domestic and textile effluents: evaluation of the efficacy and toxicological effects in Lemna minor and Daphnia magna.

Authors:  Gilberto Dias de Alkimin; Cintia Paisio; Elizabeth Agostini; Bruno Nunes
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-12       Impact factor: 4.223

3.  Spatial autocorrelation analysis of Chinese inter-provincial industrial chemical oxygen demand discharge.

Authors:  Xiaofeng Zhao; Xianjin Huang; Yibo Liu
Journal:  Int J Environ Res Public Health       Date:  2012-05-25       Impact factor: 3.390

Review 4.  Fibre optic sensors for selected wastewater characteristics.

Authors:  Su Sin Chong; A R Abdul Aziz; Sulaiman W Harun
Journal:  Sensors (Basel)       Date:  2013-07-05       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.