Literature DB >> 21847397

Lateral decubitus positioning stereotactic vacuum-assisted breast biopsy with true lateral mammography.

Youn Joo Jung1, Young Tae Bae, Jee Yeon Lee, Hyung-Il Seo, Jee Yeon Kim, Ki Seok Choo.   

Abstract

Stereotactic vacuum-assisted breast biopsy (VAB) has been used to evaluate microcalcifications or non-palpable breast lesions on mammography. Although stereotactic VAB is usually performed in a prone or upright position, an expensive prone table is necessary and vasovagal reactions often occur during the procedure. For these reasons, the lateral decubitus position can be applied for stereotactic VAB, and true lateral mammography can be used to detect the lesion. We report on 15 cases of lateral decubitus positioning for stereotactic VAB with true lateral mammography for non-palpable breast lesions or microcalcifications. The mean procedure time was approximately 30.1 minutes, and no complications occurred during the procedures. Fourteen cases had benign breast lesions and one case had a ductal carcinoma in situ. The lateral decubitus stereotactic VAB with true lateral mammography can be applied for microcalcifications or non-palpable breast lesions and helps to minimize anxiety and vasovagal reactions in patients.

Entities:  

Keywords:  Breast biopsy; Lateral positioning; Mammography; Stereotactic techniques

Year:  2011        PMID: 21847397      PMCID: PMC3148512          DOI: 10.4048/jbc.2011.14.1.64

Source DB:  PubMed          Journal:  J Breast Cancer        ISSN: 1738-6756            Impact factor:   3.588


  15 in total

1.  11-gauge vacuum assisted directional biopsy of breast calcifications, using upright stereotactic guidance.

Authors:  A P Nisbet; A Borthwick-Clarke; N Scott
Journal:  Eur J Radiol       Date:  2000-12       Impact factor: 3.528

2.  The value of a combination of wire localization and ultrasound-guided vacuum-assisted breast biopsy for clustered microcalcifications.

Authors:  Ki Seok Choo; Hee Suk Kwak; Young Tae Bae; Jee-Yeon Lee; Seung Ju Lee; Hyoung Il Seo; Su Bong Nam
Journal:  Breast       Date:  2008-07-24       Impact factor: 4.380

3.  Diagnostic accuracy of vacuum-assisted biopsy device for image-detected breast lesions.

Authors:  W K Hung; H S Lam; Y Lau; C M Chan; A W Yip
Journal:  ANZ J Surg       Date:  2001-08       Impact factor: 1.872

4.  Stereotactic breast biopsy: recumbent biopsy using add-on upright equipment.

Authors:  G J Welle; M Clark; S Loos; D Pauls; D Warden; M Sheffield; C Parsells
Journal:  AJR Am J Roentgenol       Date:  2000-07       Impact factor: 3.959

5.  Breast biopsy for mammographically detected non-palpable lesions using a vacuum-assisted biopsy device (Mammotome) and an upright-type stereotactic mammography unit.

Authors:  S Ohsumi; S Takashima; K Aogi; M Ishizaki; K Mandai
Journal:  Jpn J Clin Oncol       Date:  2001-11       Impact factor: 3.019

6.  Vacuum-assisted breast biopsy on digital stereotaxic table of nonpalpable lesions non-recognisable by ultrasonography.

Authors:  L Apesteguía; M Mellado; J Sáenz; J L Cordero; B Repáraz; C De Miguel
Journal:  Eur Radiol       Date:  2001-11-29       Impact factor: 5.315

7.  Upright stereotactic vacuum-assisted needle biopsy of suspicious breast microcalcifications.

Authors:  L S J Sim; P L Kei
Journal:  J Med Imaging Radiat Oncol       Date:  2008-08       Impact factor: 1.735

8.  Low-risk palpable breast masses removed using a vacuum-assisted hand-held device.

Authors:  Richard E Fine; Pat W Whitworth; Julian A Kim; Jay K Harness; Beth A Boyd; William E Burak
Journal:  Am J Surg       Date:  2003-10       Impact factor: 2.565

9.  Long-term results after excision of breast mass using a vacuum-assisted biopsy device.

Authors:  Cha Kyong Yom; Byung In Moon; Kuk Jin Choe; Hye Young Choi; Yong Lai Park
Journal:  ANZ J Surg       Date:  2009-11       Impact factor: 1.872

10.  Stereotactic vacuum-assisted breast biopsy in 2874 patients: a multicenter study.

Authors:  Ute Kettritz; Kerstin Rotter; Ingrid Schreer; Margarete Murauer; Rüdiger Schulz-Wendtland; Daniela Peter; Sylvia H Heywang-Köbrunner
Journal:  Cancer       Date:  2004-01-15       Impact factor: 6.860

View more
  3 in total

1.  Non-stereotactic method involving combination of ultrasound-guided wire localization and vacuum-assisted breast biopsy for microcalcification.

Authors:  Jeeyeon Lee; Ho Yong Park; Jin Hyang Jung; Wan Wook Kim; Seung Ook Hwang; Taek Ju Kwon; Jin Ho Chung; Youngtae Bae
Journal:  Gland Surg       Date:  2016-06

2.  Breast Microcalcifications: Diagnostic Outcomes According to Image-Guided Biopsy Method.

Authors:  Sohi Bae; Jung Hyun Yoon; Hee Jung Moon; Min Jung Kim; Eun-Kyung Kim
Journal:  Korean J Radiol       Date:  2015-08-21       Impact factor: 3.500

3.  Absence of Residual Microcalcifications in Atypical Ductal Hyperplasia Diagnosed via Stereotactic Vacuum-Assisted Breast Biopsy: Is Surgical Excision Obviated?

Authors:  Inyoung Youn; Min Jung Kim; Hee Jung Moon; Eun-Kyung Kim
Journal:  J Breast Cancer       Date:  2014-09-30       Impact factor: 3.588

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.