Literature DB >> 21843678

Surface plasmon resonance biosensor with high anti-fouling ability for the detection of cardiac marker troponin T.

Jen Tsai Liu1, Ching Jung Chen, Toshiyuki Ikoma, Tomohiko Yoshioka, Jeffrey S Cross, Shwu-Jen Chang, Jang-Zern Tsai, Junzo Tanaka.   

Abstract

Designing a surface recognition layer with high anti-fouling ability, high affinity, and high specificity is an important issue to produce high sensitivity biosensing transducers. In this study, a self-assembled monolayer (SAM) consisting of a homogeneous mixture of oligo(ethylene glycol) (OEG)-terminated alkanethiolate and mercaptohexadecanoic acid (MHDA) on Au was employed for immobilizing troponin T antibody and applied in detecting cardiac troponin T by using surface plasmon resonance (SPR). The mixed SAM showed no phase segregation and exhibited human serum albumin resistance, particularly with an antibody-immobilized surface. X-ray photoemission spectra revealed that the chemical composition ratio of OEG to the mixed SAM was 69% and the OEG packing density was 82%. The specific binding of troponin T on the designed surface indicated a good linear correlation (R=0.991, P<0.0009) at concentrations lower than 50 μgmL(-1) with the limit of detection of 100 ngmL(-1) using a SPR measuring instrument. It is concluded that the mixed SAM functions as designed since it has high detection capability, high accuracy and reproducibility, as well as shows strong potential to be applied in rapid clinical diagnosis for label-free detection within 2 min.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21843678     DOI: 10.1016/j.aca.2011.07.019

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  An electrochemical troponin T aptasensor based on the use of a macroporous gold nanostructure.

Authors:  Masoud Negahdary; Mostafa Behjati-Ardakani; Hossein Heli
Journal:  Mikrochim Acta       Date:  2019-05-27       Impact factor: 5.833

2.  Flexible electrical aptasensor using dielectrophoretic assembly of graphene oxide and its subsequent reduction for cardiac biomarker detection.

Authors:  Abhinav Sharma; Jaesung Jang
Journal:  Sci Rep       Date:  2019-04-12       Impact factor: 4.379

Review 3.  Cardiac Troponin Biosensor Designs: Current Developments and Remaining Challenges.

Authors:  Andreea Campu; Ilinca Muresan; Ana-Maria Craciun; Simona Cainap; Simion Astilean; Monica Focsan
Journal:  Int J Mol Sci       Date:  2022-07-13       Impact factor: 6.208

Review 4.  Cardiovascular biomarkers in body fluids: progress and prospects in optical sensors.

Authors:  Reena V John; Tom Devasiya; Nidheesh V R; Sphurti Adigal; Jijo Lukose; V B Kartha; Santhosh Chidangil
Journal:  Biophys Rev       Date:  2022-08-18