Brain images acquired at 3T often display central brightening with spatially varying tissue contrast, caused by inhomogeneity in the transmit radiofrequency fields used for excitation. Tailored radiofrequency pulses can provide mitigation of radiofrequency field inhomogeneity, but previous designs have been unsuitable for 3D imaging in rapid pulse sequences. This article presents a nonselective pulse design based on a short (1 ms) 3D spiral k-space trajectory that covers low spatial frequencies. The resulting excitations are optimized to produce a uniform excitation within a specified volume of interest covering the whole brain. B1 mapping and pulse calculation times were reduced by optimizing in only five slices within the brain. The method has been tested with both single and parallel transmission: in phantom experiments, normalized root-mean-square error in excitation was 0.022 for single and 0.020 for parallel transmission. The corresponding results in vivo were 0.066 and 0.055 respectively. A pilot brain imaging study using the proposed pulses for excitation within the Alzheimer's disease neuroimaging initiative magnetization prepared rapid gradient echo (MP-RAGE) protocol, yielded excellent image quality with improved signal to noise ratio in peripheral brain regions and enhanced uniformity of contrast compared with standard excitation. Greatest performance enhancement was achieved using parallel transmission, but single channel transmission offers significant improvement over standard excitation pulses.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21842503     DOI: 10.1002/mrm.23118

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  30 in total

1.  Strategies for improved 3D small-tip fast recovery imaging.

Authors:  Hao Sun; Jeffrey A Fessler; Douglas C Noll; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2013-10-11       Impact factor: 4.668

2.  Human Connectome Project-style resting-state functional MRI at 7 Tesla using radiofrequency parallel transmission.

Authors:  Xiaoping Wu; Edward J Auerbach; An T Vu; Steen Moeller; Pierre-François Van de Moortele; Essa Yacoub; Kâmil Uğurbil
Journal:  Neuroimage       Date:  2018-09-17       Impact factor: 6.556

3.  A generalized slab-wise framework for parallel transmit multiband RF pulse design.

Authors:  Xiaoping Wu; Sebastian Schmitter; Edward J Auerbach; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Magn Reson Med       Date:  2015-05-20       Impact factor: 4.668

4.  Simultaneous fat saturation and magnetization transfer contrast imaging with steady-state incoherent sequences.

Authors:  Feng Zhao; Jon-Fredrik Nielsen; Scott D Swanson; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2014-09-22       Impact factor: 4.668

5.  Real-time assessment of potential peak local specific absorption rate value without phase monitoring: Trigonometric maximization method for worst-case local specific absorption rate determination.

Authors:  Ettore Flavio Meliadò; Alessandro Sbrizzi; Cornelis A T van den Berg; Peter R Luijten; Alexander J E Raaijmakers
Journal:  Magn Reson Med       Date:  2020-12-22       Impact factor: 4.668

6.  Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI.

Authors:  Sun Hao; Jeffrey A Fessler; Douglas C Noll; Jon-Fredrik Nielsen
Journal:  IEEE Trans Med Imaging       Date:  2015-09-15       Impact factor: 10.048

7.  Local SAR, global SAR, and power-constrained large-flip-angle pulses with optimal control and virtual observation points.

Authors:  Mads S Vinding; Bastien Guérin; Thomas Vosegaard; Niels Chr Nielsen
Journal:  Magn Reson Med       Date:  2015-12-30       Impact factor: 4.668

8.  Designing parallel transmit head coil arrays based on radiofrequency pulse performance.

Authors:  Zhipeng Cao; Xinqiang Yan; John C Gore; William A Grissom
Journal:  Magn Reson Med       Date:  2019-11-13       Impact factor: 4.668

9.  Four dimensional spectral-spatial fat saturation pulse design.

Authors:  Feng Zhao; Jon-Fredrik Nielsen; Douglas C Noll
Journal:  Magn Reson Med       Date:  2013-12-17       Impact factor: 4.668

10.  Fast three-dimensional inner volume excitations using parallel transmission and optimized k-space trajectories.

Authors:  Mathias Davids; Lothar R Schad; Lawrence L Wald; Bastien Guérin
Journal:  Magn Reson Med       Date:  2015-11-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.