Literature DB >> 21841188

Evaluation of pulmonary vein stenosis after pulmonary vein isolation using a novel circular mapping and ablation catheter (PVAC).

Christian von Bary1, Stefan Weber, Christian Dornia, Christoph Eissnert, Claudia Fellner, Philipp Latzin, Sabine Fredersdorf, Stefan Stadler, Okka W Hamer.   

Abstract

BACKGROUND: Pulmonary vein stenosis (PVST) is a well-known complication of pulmonary vein isolation (PVI). Specific anatomically designed ablation catheters for antral PVI have not been evaluated with regard to the incidence of PVST. We investigated the incidence, severity, and characteristics of PVST after PVI with the Pulmonary Vein Ablation Catheter (PVAC) and phased radiofrequency technology. METHODS AND
RESULTS: A total of 100 patients (55 men) underwent PVI for atrial fibrillation using the PVAC. PVI was guided by selective angiography of each pulmonary vein (PV) in 70 (70%) patients and by reconstructed 3D atriography (ATG) in 30 (30%) patients. Gadolinium-enhanced MRI or multidetector CT was performed in all patients before treatment and 93±78 days after PVI. PVST was classified as follows: insignificant (<25%), mild (25%-50%), moderate (50%-75%), or severe (>75%). A total of 410 PVs were analyzed. Cardiac imaging demonstrated a detectable narrowing of the PV diameter in 23 (23%) patients and in 28 (7%) PVs. In detail, insignificant PVST was observed in 12 (2.9%) PVs, mild PVST in 15 (3.7%), and moderate PVST in 1 (0.2%). No instances of severe PVST were observed. The use of 3D-ATG was associated with a lower incidence of PVST (0.8% [95% CI, 0.0%-2.2%] versus 5.4% [95% CI, 2.7%-8.1%], P=0.027).
CONCLUSIONS: To our knowledge, this study is the first to report the incidence of PVST using the PVAC. In this regard, the PVAC seems to be safe if used in an experienced center. In addition, the use of 3D-ATG may decrease the risk of PVST.

Entities:  

Mesh:

Year:  2011        PMID: 21841188     DOI: 10.1161/CIRCEP.111.963397

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  13 in total

Review 1.  Collateral Damage During Ablation of Atrial Fibrillation - Lessons Learnt in the Past Decade.

Authors:  David Spragg
Journal:  J Atr Fibrillation       Date:  2012-02-02

2.  A 5-year clinical follow-up after duty-cycled phased RF ablation of paroxysmal atrial fibrillation.

Authors:  Antoine Lepillier; Xavier Copie; Gilles Lascault; Olivier Paziaud; Olivier Piot
Journal:  J Interv Card Electrophysiol       Date:  2016-11-22       Impact factor: 1.900

Review 3.  The Impact of Advances in Atrial Fibrillation Ablation Devices on the Incidence and Prevention of Complications.

Authors:  Fehmi Keçe; Katja Zeppenfeld; Serge A Trines
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

4.  Silent cerebral events as a result of left atrial catheter ablation do not cause neuropsychological sequelae--a MRI-controlled multicenter study.

Authors:  Christian von Bary; Thomas Deneke; Thomas Arentz; Anja Schade; Heiko Lehrmann; Christoph Eissnert; Susanne Schwab-Malek; Sabine Fredersdorf; Ekrem Ücer; Dobri Baldaranov; Christina Wendl; Felix Schlachetzki
Journal:  J Interv Card Electrophysiol       Date:  2015-04-29       Impact factor: 1.900

5.  Clinical outcomes of AF patients treated with the first and second-generation of circular mapping and ablation catheter: insights from a real world multicenter experience.

Authors:  Giovanni Rovaris; Paolo De Filippo; Francesco Laurenzi; Gabriele Zanotto; Nicola Bottoni; Mattia Pozzi; Fabrizio Giofrè; Piergiuseppe De Girolamo; Emanuela Visentin; Elena Piazzi; Paola Ferrari
Journal:  J Interv Card Electrophysiol       Date:  2017-09-05       Impact factor: 1.900

6.  First results and follow-up of a second-generation circular mapping and ablation catheter.

Authors:  Stefan Weber; Martin Höher; Dominik Schultes
Journal:  J Interv Card Electrophysiol       Date:  2016-05-26       Impact factor: 1.900

7.  Pulmonary vein obstruction after catheter ablation in a patient with partial anomalous pulmonary vein connection.

Authors:  Tadashi Omoto; Atsushi Aoki; Kazuto Maruta; Tomoaki Masuda; Taku Asano; Youichi Kobayashi
Journal:  J Cardiol Cases       Date:  2016-05-26

8.  Pulmonary vein stenosis after pulmonary vein isolation using duty-cycled unipolar/bipolar radiofrequency ablation guided by intracardiac echocardiography.

Authors:  Stefan Asbach; Fabienne Schluermann; Luca Trolese; Mathias Langer; Christoph Bode; Tobias Krauss
Journal:  J Interv Card Electrophysiol       Date:  2015-06-17       Impact factor: 1.900

Review 9.  The incidence, diagnosis, and management of pulmonary vein stenosis as a complication of atrial fibrillation ablation.

Authors:  Armand Rostamian; Sanjiv M Narayan; Louise Thomson; Michael Fishbein; Robert J Siegel
Journal:  J Interv Card Electrophysiol       Date:  2014-03-14       Impact factor: 1.900

10.  Observations and Considerations on Patient X-ray Exposure in the Electrophysiology Lab.

Authors:  Xianxian Jiang; Lukas Rc Dekker
Journal:  Arrhythm Electrophysiol Rev       Date:  2013-11-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.