Literature DB >> 21839443

A biomechanical study on variation of compressive force along the Acutrak 2 screw.

Hari Kovilazhikathu Sugathan1, Max Kilpatrick, Tom J Joyce, John W K Harrison.   

Abstract

INTRODUCTION: Acutrak 2 screws are commonly used for scaphoid fracture fixation. To our knowledge, the variation in compressive force along the screw has not been investigated before. The objectives of our study were to measure variance in compression along the length of the standard Acutrak 2 screw, to identify the region of the screw which produces the greatest compression and to discuss the clinical relevance of this to the placement of the screw for scaphoid fractures.
MATERIALS AND METHODS: A laboratory model was set up to test the compressive force at 2mm intervals along the screw, using solid polyurethane foam (Sawbone) blocks of varying width. The Acutrak 2 screws were introduced in the standard method. Forces were measured using a custom-made load cell washer introduced between the Sawbone blocks and were plotted as a graph along the whole length of the screw.
RESULTS: Maximum compression was at the mid-point of the screw. Overall compressive forces were higher in the proximal half of the screw by 19% when compared with the distal half. Minimum compression was seen at 4mm or less from either end of the screw.
CONCLUSIONS: There is variation in compression along the length of the standard Acutrak 2 screw and the maximum compression was obtained at the mid-point of the screw. From this study, we would recommend when using an Acutrak 2 screw for internal fixation of scaphoid fractures, to attain maximum compressive force, place the fracture at the mid-point of the Acutrak screw. If this is not possible, then place the fracture towards the proximal half of the screw.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21839443     DOI: 10.1016/j.injury.2011.07.011

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  10 in total

1.  Insertion profiles of 4 headless compression screws.

Authors:  Adam Hart; Edward J Harvey; Louis-Philippe Lefebvre; Francois Barthelat; Reza Rabiei; Paul A Martineau
Journal:  J Hand Surg Am       Date:  2013-06-25       Impact factor: 2.230

2.  Impact of Screw Length on Proximal Scaphoid Fracture Biomechanics.

Authors:  Samik Patel; Juan Giugale; Nathan Tiedeken; Richard E Debski; John R Fowler
Journal:  J Wrist Surg       Date:  2019-04-22

3.  Effect of Screw Length and Geometry on Interfragmentary Compression in a Simulated Proximal Pole Scaphoid Fracture Model.

Authors:  Samik Patel; Juan M Giugale; Richard E Debski; John R Fowler
Journal:  Hand (N Y)       Date:  2018-08-20

4.  Effect of Screw Perpendicularity on Compression in Scaphoid Waist Fractures.

Authors:  Morgan M Swanstrom; Kyle W Morse; Joseph D Lipman; Krystle A Hearns; Michelle G Carlson
Journal:  J Wrist Surg       Date:  2016-12-01

5.  A Biomechanical Comparison of Screw and Plate Fixations for Scaphoid Fractures.

Authors:  Jill Goodwin; Paulo Castañeda; Patricia Drace; Scott Edwards
Journal:  J Wrist Surg       Date:  2017-08-14

6.  Interfragmentary Compression Forces Vary Based on Scaphoid Bone Screw Type and Fracture Location.

Authors:  Samik Patel; Nathan Tiedeken; Lars Qvick; Richard E Debski; Robert Kaufmann; John R Fowler
Journal:  Hand (N Y)       Date:  2017-12-15

7.  Which Headless Compression Screw Produces the Highest Interfragmentary Compression Force in Scaphoid Fracture?

Authors:  Karthik Vishwanathan; Ravi Patel; Sumedh Talwalkar
Journal:  Indian J Orthop       Date:  2020-04-22       Impact factor: 1.251

8.  Rotational Stability of Scaphoid Osteosyntheses: An In Vitro Comparison of Small Fragment Cannulated Screws to Novel Bone Screw Sets.

Authors:  Jochen Erhart; Ewald Unger; Philip Schefzig; Peter Varga; Inga Trulson; Anna Gormasz; Alexander Trulson; Martin Reschl; Michael Hagmann; Vilmos Vecsei; Winfried Mayr
Journal:  PLoS One       Date:  2016-06-03       Impact factor: 3.240

9.  Impact of Different Screw Designs on Durability of Fracture Fixation: In Vitro Study with Cyclic Loading of Scaphoid Bones.

Authors:  Dominik Gruszka; Robert Herr; Hans Hely; Peer Hofmann; Daniela Klitscher; Alexander Hofmann; Pol Maria Rommens
Journal:  PLoS One       Date:  2016-01-07       Impact factor: 3.240

10.  Comparison between headless cannulated screws and partially threaded screws in femoral neck fracture treatment: a retrospective cohort study.

Authors:  Yilin Wang; Na Han; Dianying Zhang; Peixun Zhang; Baoguo Jiang
Journal:  Sci Rep       Date:  2022-02-02       Impact factor: 4.379

  10 in total