Literature DB >> 21835077

Cutaneous sensory deficit following post-auricular incision.

S J Frampton1, M Pringle.   

Abstract

INTRODUCTION: Post-auricular incisions are performed for a range of otological procedures. Anecdotally, many patients suffer some numbness of the pinna or post-auricular skin post-operatively, but for most this appears to reduce with time. This study aimed to investigate this phenomenon.
METHODS: A single centre, questionnaire-based study was undertaken, assessing the presence of numbness beyond eight months post-surgery, its location, how it changed, and its impact on the patient. Patients whose numbness had resolved provided details of any temporary deficit. Data were acquired for 35 primary and 16 revision procedures. RESULTS AND
CONCLUSION: Sixty-nine per cent of patients undergoing primary surgery experienced post-operative numbness. Twenty-six per cent had continued numbness after at least eight months' recovery, but only 3 per cent were constantly aware of the deficit. Of those with an ongoing deficit, 78 per cent felt there had been a reduction in the severity, and 67 per cent in the area size, over time. Recovery appeared to be slightly worse in revision cases.

Entities:  

Mesh:

Year:  2011        PMID: 21835077     DOI: 10.1017/S002221511100199X

Source DB:  PubMed          Journal:  J Laryngol Otol        ISSN: 0022-2151            Impact factor:   1.469


  3 in total

1.  Sensation Loss of Auricle Following Ear Surgery by Post-auricular Incision: Our Experience.

Authors:  Sanket D Vakharia; Seema R Gupta
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2020-06-13

2.  Patient satisfaction with postaural incision site.

Authors:  George Barrett; Susanne Koecher; Natalie Ronan; David Whinney
Journal:  Int J Otolaryngol       Date:  2014-09-24

3.  Endoscopic single versus double flap tympanoplasty: a randomized clinical trial.

Authors:  Noha Ahmed El-Kholy; Mohammed Abdelbadie Salem; Abdelwahab Mohamed Rakha
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-07-20       Impact factor: 3.236

  3 in total