Literature DB >> 21833785

Mismatch of anatomically pre-shaped locking plate on Asian femurs could lead to malalignment in the minimally invasive plating of distal femoral fractures: a cadaveric study.

Jin-Ho Hwang1, Jong-Keon Oh, Chang-Wug Oh, Yong-Cheol Yoon, Hyeuk Woo Choi.   

Abstract

BACKGROUND: LCP-DF (locking compression plate-distal femur) has been introduced as an anatomically pre-shaped plate that does not require further contouring. However, the LCP-DF was developed based on skeletal measurements in Caucasians. It is unknown whether the LCP-DF fits Asians.
OBJECTIVE: The purpose of this study was to assess the conformity of the LCP-DF in Asian adult femurs and also to determine the matching pattern of this anatomically pre-shaped LCP-DF in normal Asian adult femurs and the clinical implications of the matching pattern.
METHODS: Sixty adult cadaver femurs were obtained from 41 male and 19 female cadavers with an average age of 63 years (31-95). An 11-hole LCP-DF was applied to the lateral surface of the distal femur according to the contour. Any mismatches between the bone and the plate were recorded. Then the distance from the inner surface of the plate to the cortex was measured at the sites of mismatch. C-arm AP image of the distal femur was taken and the angle between the distal most locking screw and the joint line was measured, and it was named as joint screw angle (JSA).
RESULTS: Mismatch was found at the level of proximal 4-5 holes of the plate with an average distance of 11.36 mm (range 0-32 mm) at the tip of the plate. Otherwise, the overall conformity of the LCP-DF was good. The average JSA was 2.15 ± 1.78° (ranged from 0° to 5°).
CONCLUSION: A rather consistent pattern of mismatch was found at the proximal part of the 11-hole LCP-DF. An attempt to fit the plate to the bone at this level may cause valgus malalignment at the fracture site.

Entities:  

Mesh:

Year:  2011        PMID: 21833785     DOI: 10.1007/s00402-011-1375-5

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  5 in total

1.  Anatomical fitting of a plate shape directly derived from a 3D statistical bone model of the tibia.

Authors:  Beat Schmutz; Kanchana Rathnayaka; Thomas Albrecht
Journal:  J Clin Orthop Trauma       Date:  2019-04-25

2.  Complex AO type C3 distal femur fractures: Results after fixation with a lateral locked plate using modified swashbuckler approach.

Authors:  Anuj Agrawal; Vivek Kiyawat
Journal:  Indian J Orthop       Date:  2017 Jan-Feb       Impact factor: 1.251

3.  Minimally invasive plate osteosynthesis for complex comminuted bone fractures in the Fraser's type II floating knee: a case report.

Authors:  Chuangang Peng; Guangkai Ren; Minghan Dou; Baoming Yuan; Dankai Wu
Journal:  Eur J Med Res       Date:  2022-03-02       Impact factor: 2.175

4.  Convenient design method for customized implants based on bionic vein structure features.

Authors:  Lin Wang; Weizhong Geng; Kunjin He; Kaijin Guo
Journal:  Front Bioeng Biotechnol       Date:  2022-08-12

5.  Bone morphological feature extraction for customized bone plate design.

Authors:  Lin Wang; Kaijin Guo; Kunjin He; Hong Zhu
Journal:  Sci Rep       Date:  2021-08-02       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.