Literature DB >> 21832270

Accuracy and reliability of cone-beam computed tomography for airway volume analysis.

Ahmed Ghoneima1, Katherine Kula.   

Abstract

The purpose of the present study was to evaluate the accuracy and reliability of airway volume digital measurements of cone-beam computed tomography (CBCT) compared with the manual measurements of an airway model. An acrylic airway model was constructed and attached to a human dry skull in the natural position of the airway passage. The total and internal airway volumes, as well as the most constricted airway area, were measured manually on the model and on the CBCTs taken after the model was attached to the skull. The CBCT images were analysed using the Dolphin3D (Dolphin Imaging & Management solutions, Chatsworth, California, USA) software. Reliability and accuracy were assessed by using intraclass correlation and Student's t-test. A P ≤ 0.05 was considered statistically significant. No significant statistical difference was found between the total, the internal airway volume, and the most constricted airway area measured on CBCTs compared with the manual measurements. The intra-examiner reliability was high for all measurements recorded from both methods (r ≥ 0.90). These results suggested that the three-dimensional CBCT digital measurements of the airway volume and the most constricted area of the airway are reliable and accurate. The use of CBCT imaging for the assessment of the airway can provide clinically useful information in orthodontics.

Entities:  

Mesh:

Year:  2011        PMID: 21832270     DOI: 10.1093/ejo/cjr099

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  18 in total

1.  Reliability and accuracy of three imaging software packages used for 3D analysis of the upper airway on cone beam computed tomography images.

Authors:  Hui Chen; Maureen van Eijnatten; Jan Wolff; Jan de Lange; Paul F van der Stelt; Frank Lobbezoo; Ghizlane Aarab
Journal:  Dentomaxillofac Radiol       Date:  2017-06-14       Impact factor: 2.419

2.  Evaluation of the oropharynx in class I and II skeletal patterns by CBCT.

Authors:  Milena Cabral; Leila Ribeiro Brito de Queiroz Ribeiro; Carlos Maurício Cardeal; Marcos Alan Vieira Bittencourt; Iêda Margarida Crusoé-Rebello; Adelmir Souza-Machado
Journal:  Oral Maxillofac Surg       Date:  2016-11-26

3.  Proposal of new upper airway margins in children assessed by CBCT.

Authors:  S Anandarajah; Y Abdalla; R Dudhia; L Sonnesen
Journal:  Dentomaxillofac Radiol       Date:  2015-03-25       Impact factor: 2.419

4.  Comparing dimensions of upper airway in patients with nasal septal deviation and healthy people in CBCT.

Authors:  Nasim Jafari-Pozve; Hamidreza Kiani; Seyed-Sasan Aryanezhad
Journal:  Am J Nucl Med Mol Imaging       Date:  2022-02-15

5.  Impact of Le-Fort I osteotomy on anatomical and functional aspects of the nasal airway and on quality of life.

Authors:  Karim Zaoui; Reinald Kuehle; Ingo Baumann; Dorothee Laura Schuessler; Oliver Ristow; Michaela Plath; Christian Freudlsperger
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-01-14       Impact factor: 2.503

6.  Short-term pharyngeal airway changes after mandibular advancement surgery in adult Class II-Patients--a three-dimensional retrospective study.

Authors:  Janka Kochel; Philipp Meyer-Marcotty; Franka Sickel; Helmut Lindorf; Angelika Stellzig-Eisenhauer
Journal:  J Orofac Orthop       Date:  2013-03-08       Impact factor: 1.938

7.  Three-dimensional airway evaluation in 387 subjects from one university orthodontic clinic using cone beam computed tomography.

Authors:  Chuen Chie Chiang; Meghan N Jeffres; Arthur Miller; David C Hatcher
Journal:  Angle Orthod       Date:  2012-06-04       Impact factor: 2.079

8.  A three dimensional study of upper airway in adult skeletal Class II patients with different vertical growth patterns.

Authors:  Tianhu Wang; Zhenhua Yang; Fang Yang; Mingye Zhang; Jinlong Zhao; Jinwu Chen; Yongming Li
Journal:  PLoS One       Date:  2014-04-22       Impact factor: 3.240

Review 9.  A consideration of factors affecting palliative oral appliance effectiveness for obstructive sleep apnea: a scoping review.

Authors:  Bruce S Haskell; Michael J Voor; Andrew M Roberts
Journal:  J Clin Sleep Med       Date:  2021-04-01       Impact factor: 4.062

Review 10.  Effect of Head and Tongue Posture on the Pharyngeal Airway Dimensions and Morphology in Three-Dimensional Imaging: a Systematic Review.

Authors:  Sirwan Fernandez Gurani; Gabriele Di Carlo; Paolo M Cattaneo; Jens Jørgen Thorn; Else Marie Pinholt
Journal:  J Oral Maxillofac Res       Date:  2016-03-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.