Literature DB >> 21831552

Quantification of left and right ventricular function and myocardial mass: comparison of low-radiation dose 2nd generation dual-source CT and cardiac MRI.

Richard A P Takx1, Antonio Moscariello, U Joseph Schoepf, J Michael Barraza, John W Nance, Gorka Bastarrika, Marco Das, Mathias Meyer, Joachim E Wildberger, Stefan O Schoenberg, Christian Fink, Thomas Henzler.   

Abstract

OBJECTIVE: To prospectively evaluate the accuracy of left and right ventricular function and myocardial mass measurements based on a dual-step, low radiation dose protocol with prospectively ECG-triggered 2nd generation dual-source CT (DSCT), using cardiac MRI (cMRI) as the reference standard.
MATERIALS AND METHODS: Twenty patients underwent 1.5T cMRI and prospectively ECG-triggered dual-step pulsing cardiac DSCT. This image acquisition mode performs low-radiation (20% tube current) imaging over the majority of the cardiac cycle and applies full radiation only during a single adjustable phase. Full-radiation-phase images were used to assess cardiac morphology, while low-radiation-phase images were used to measure left and right ventricular function and mass. Quantitative CT measurements based on contiguous multiphase short-axis reconstructions from the axial CT data were compared with short-axis SSFP cardiac cine MRI. Contours were manually traced around the ventricular borders for calculation of left and right ventricular end-diastolic volume, end-systolic volume, stroke volume, ejection fraction and myocardial mass for both modalities. Statistical methods included independent t-tests, the Mann-Whitney U test, Pearson correlation statistics, and Bland-Altman analysis.
RESULTS: All CT measurements of left and right ventricular function and mass correlated well with those from cMRI: for left/right end-diastolic volume r=0.885/0.801, left/right end-systolic volume r=0.947/0.879, left/right stroke volume r=0.620/0.697, left/right ejection fraction r=0.869/0.751, and left/right myocardial mass r=0.959/0.702. Mean radiation dose was 6.2±1.8mSv.
CONCLUSIONS: Prospectively ECG-triggered, dual-step pulsing cardiac DSCT accurately quantifies left and right ventricular function and myocardial mass in comparison with cMRI with substantially lower radiation exposure than reported for traditional retrospective ECG-gating.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21831552     DOI: 10.1016/j.ejrad.2011.07.001

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  24 in total

Review 1.  Assessment of coronary heart disease by CT angiography: current and evolving applications.

Authors:  Abhishek Sharma; Armin Arbab-Zadeh
Journal:  J Nucl Cardiol       Date:  2012-08       Impact factor: 5.952

2.  Computed tomography of dynamic changes of the aortic root during systole and diastole in patients with coronary artery calcification.

Authors:  Xiaohan Hu; Claudia Frellesen; Ralf W Bauer; J Matthias Kerl; Martin Beeres; Boris Bodelle; Thomas Lehnert; Thomas J Vogl; Julian L Wichmann
Journal:  Radiol Med       Date:  2015-02-03       Impact factor: 3.469

3.  Fully automated right ventricular volumetry from ECG-gated coronary CT angiography data: evaluation of prototype software.

Authors:  Thomas Lehnert; Anna Wrzesniak; Dominik Bernhardt; Hanns Ackermann; J Matthias Kerl; Fernando Vega-Higuera; Thomas J Vogl; Ralf W Bauer
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-14       Impact factor: 2.357

4.  Dose levels and image quality of second-generation 128-slice dual-source coronary CT angiography in clinical routine.

Authors:  Julian L Wichmann; Xiaohan Hu; Alexander Engler; J Matthias Kerl; Martin Beeres; Claudia Frellesen; Wolfgang Luboldt; Thomas J Vogl; Ralf W Bauer; Thomas Lehnert
Journal:  Radiol Med       Date:  2015-05-16       Impact factor: 3.469

5.  CT compared to MRI for functional evaluation of the right ventricle: a systematic review and meta-analysis.

Authors:  Hang Fu; Xuedong Wang; Kaiyue Diao; Shan Huang; Hui Liu; Yue Gao; Qin Zhao; Zhi-Gang Yang; Ying-Kun Guo
Journal:  Eur Radiol       Date:  2019-05-27       Impact factor: 5.315

6.  Technical feasibility of semiautomatic three-dimensional threshold-based cardiac computed tomography quantification of left ventricular mass.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2018-11-23

7.  CT fractional flow reserve: the next level in non-invasive cardiac imaging.

Authors:  M F L Meijs; M J Cramer; H El Aidi; P A Doevendans
Journal:  Neth Heart J       Date:  2012-10       Impact factor: 2.380

8.  Advances in cardiac CT contrast injection and acquisition protocols.

Authors:  Jan-Erik Scholtz; Brian Ghoshhajra
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

9.  Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI.

Authors:  Yuzo Yamasaki; Michinobu Nagao; Kenichiro Yamamura; Masato Yonezawa; Yoshio Matsuo; Satoshi Kawanami; Takeshi Kamitani; Ko Higuchi; Ichiro Sakamoto; Yuichi Shiokawa; Hidetake Yabuuchi; Hiroshi Honda
Journal:  Eur Radiol       Date:  2014-08-12       Impact factor: 5.315

10.  Evaluation of right ventricular volume and ejection fraction by gated (18)F-FDG PET in patients with pulmonary hypertension: comparison with cardiac MRI and CT.

Authors:  Lei Wang; Yan Zhang; Chaowu Yan; Jianguo He; Changming Xiong; Shihua Zhao; Wei Fang
Journal:  J Nucl Cardiol       Date:  2013-01-26       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.