Literature DB >> 2182798

Effect of background correction on separate technetium-99m-DTPA renal clearance.

A Piepsz1, A Dobbeleir, H R Ham.   

Abstract

The estimation of the background constitutes the main difficulty in the accurate determination of the separate renal clearance, using the 99mTc-DTPA complex and the gamma camera. This is due to the low extraction rate of DTPA, giving an unfavorable signal-to-noise ratio, and to the fact that no background area can accurately represent both interstitial and vascular components of the renal curve. Several algorithms have been proposed in the literature for solving the problem of background but their effect on the calculated clearance value has not been sufficiently assessed. In this paper, it has been possible, using a theoretical approach, to predict the respective influence of the different algorithms on the renal clearance. These results were confirmed on the basis of clinical data obtained from 53 renal studies. It was shown that a double background correction, using successively the area ratio method followed by a linear fit method, is probably the most precise method and is less dependent on the choice of the background area.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2182798

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  7 in total

1.  Renal background correction and measurement of split renal function: The challenge : Editorial Comment: EJNM-D-15-00322, M Donald Blaufox, MD, PhD.

Authors:  M Donald Blaufox
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-03       Impact factor: 9.236

2.  A simple method for determining split renal function from dynamic (99m)Tc-MAG3 scintigraphic data.

Authors:  Michal J Wesolowski; Gary R Conrad; Martin Šámal; Gage Watson; Surajith N Wanasundara; Paul Babyn; Carl A Wesolowski
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-11-04       Impact factor: 9.236

Review 3.  Quantification of renal haemodynamics with radionuclides.

Authors:  A M Peters
Journal:  Eur J Nucl Med       Date:  1991

4.  The SNMMI and EANM practice guideline for renal scintigraphy in adults.

Authors:  M Donald Blaufox; Diego De Palma; Andrew Taylor; Zsolt Szabo; Alain Prigent; Martin Samal; Yi Li; Andrea Santos; Giorgio Testanera; Mark Tulchinsky
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-08-30       Impact factor: 9.236

5.  Extravascular chest wall technetium 99m diethylene triamine penta-acetic acid: implications for the measurement of renal function during renography.

Authors:  S D Bell; A M Peters
Journal:  Eur J Nucl Med       Date:  1991

6.  Guidelines for standard and diuretic renogram in children.

Authors:  Isky Gordon; Amy Piepsz; Rune Sixt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-06       Impact factor: 9.236

7.  Technetium 99m mercaptoacetyltriglycine gamma camera clearance calculations: methodological problems.

Authors:  M Tondeur; A Piepsz; A Dobbeleir; H Ham
Journal:  Eur J Nucl Med       Date:  1991
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.