Literature DB >> 21821348

Variance of speed of sound and correlation with acoustic impedance in canine corneas.

Junhua Tang1, Jun Liu.   

Abstract

The clinical standard for measuring corneal thickness is ultrasound pachymetry that assumes a constant speed of sound. The purpose of this study was to examine the variance of speed of sound and its relationship with acoustic impedance in healthy eyes of canines with a large age span. Corneal speed of sound and acoustic impedance were measured in 34 canine eyes at room temperature (21 ± 1°C). The mean speed of sound was 1577 ± 10 m/s ranging from 1553 to 1594 m/s. There was a strong correlation between speed of sound and acoustic impedance (R = 0.84, p < 0.001). Corneal speed of sound had a small variance in healthy canines over 1-year-old, but was significantly lower in younger canines suggesting an age effect. The strong correlation between corneal speed of sound and acoustic impedance may offer a potential means to noninvasively detect abnormal speed of sound for more accurate corneal thickness estimation.
Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21821348     DOI: 10.1016/j.ultrasmedbio.2011.06.012

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  4 in total

1.  In vivo evaluation of the cornea and conjunctiva of the normal laboratory beagle using time- and Fourier-domain optical coherence tomography and ultrasound pachymetry.

Authors:  Ann R Strom; Dennis E Cortés; Carol A Rasmussen; Sara M Thomasy; Kim McIntyre; Shwu-Fei Lee; Philip H Kass; Mark J Mannis; Christopher J Murphy
Journal:  Vet Ophthalmol       Date:  2015-02-10       Impact factor: 1.644

2.  Corneal thickness and anterior chamber depth of the normal adult horse as measured by ultrasound biomicroscopy.

Authors:  Kelly E Knickelbein; Mary E Lassaline; Soohyun Kim; Machal S Scharbrough; Sara M Thomasy
Journal:  Vet Ophthalmol       Date:  2022-01-27       Impact factor: 1.444

3.  Low-cost ultrasonic distance sensor arrays with networked error correction.

Authors:  Hongjun Dai; Shulin Zhao; Zhiping Jia; Tianzhou Chen
Journal:  Sensors (Basel)       Date:  2013-09-05       Impact factor: 3.576

4.  Correlation of IOP with Corneal Acoustic Impedance in Porcine Eye Model.

Authors:  Jun Zhang; Yi Zhang; Yang Li; Ruimin Chen; K Kirk Shung; Grace Richter; Qifa Zhou
Journal:  Biomed Res Int       Date:  2017-05-31       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.