| Literature DB >> 21818650 |
Yasuhiro Ichikawa1, Mari Iwamoto, Sadamitsu Yanagi, Munetaka Masuda.
Abstract
A 6-year-old girl with type 3 long QT syndrome was safely and successfully implanted with an implantable cardioverter-defibrillator (ICD) system. Prior to implantation, she had experienced uncontrollable life-threatening arrhythmia in spite of high-dose administration of mexiletine. An ICD coil lead for transvenous use was placed in the intrapericardial and retrocardial space and was connected to a generator placed in front of the posterior sheath of the right abdominal rectal muscle. Administration of a beta-blocker in addition to atrial pacing almost completely eliminated the patient's life-threatening arrhythmia attacks. Intrapericardial and retrocardial implantation of ICD coil leads might be useful for children.Entities:
Mesh:
Year: 2011 PMID: 21818650 DOI: 10.1007/s00246-011-0065-y
Source DB: PubMed Journal: Pediatr Cardiol ISSN: 0172-0643 Impact factor: 1.655