Covered skin transcutaneous bilirubin estimation is comparable with serum bilirubin during and after phototherapy.

R Fonseca1, R Kyralessa, M Malloy, J Richardson, S K Jain.   

Abstract

OBJECTIVE: To determine whether transcutaneous bilirubin (TcB) from covered skin (TcB-C) during and after discontinuing phototherapy (PHT) is reliable in treating neonatal jaundice. STUDY
DESIGN: In this prospective observational study, before starting PHT, part of the forehead was covered. TcB-C and TcB from exposed skin (TcB-E) to PHT were measured before starting PHT, on a 12-hourly basis while receiving PHT and 6 h after stopping PHT. We used ANOVA (analysis of variance) and Bonferroni's t-tests. RESULT: A total of 39 infants were enrolled (mean gestation 39 weeks, 51% males and 80% Hispanic). The mean TSB over all time periods was 10.9±2.4, TcB-C 10.9±2.4 and TcB-E 7.2±3.4. Before PHT, there were no significant differences in bilirubin by all three techniques. TcB-C was not significantly different from TSB at any time point. However, TcB-E was significantly lower during PHT and after stopping PHT.
CONCLUSION: TcB-C is a reliable method in the management of neonatal jaundice.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21818063     DOI: 10.1038/jp.2011.66

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  8 in total

1.  Accuracy of transcutaneous bilirubin measurement in newborns after phototherapy.

Authors:  L Casnocha Lucanova; K Matasova; M Zibolen; P Krcho
Journal:  J Perinatol       Date:  2016-06-09       Impact factor: 2.521

2.  Reliability of transcutaneous bilirubin determination based on skin color determined by a neonatal skin color scale of our own.

Authors:  Silvia Maya-Enero; Júlia Candel-Pau; Jordi Garcia-Garcia; Xavier Duran-Jordà; María Ángeles López-Vílchez
Journal:  Eur J Pediatr       Date:  2021-01-06       Impact factor: 3.183

3.  Reliability of transcutaneous bilirubinometry from shielded skin in neonates receiving phototherapy: a prospective cohort study.

Authors:  L Murli; A Thukral; M J Sankar; S Vishnubhatla; A K Deorari; V K Paul; A Sakariah; R Agarwal
Journal:  J Perinatol       Date:  2016-10-20       Impact factor: 2.521

4.  Efficacy of transcutaneous bilirubinometry as compared to serum bilirubin in preterm newborn during phototherapy.

Authors:  Sunil Gothwal; Neelam Singh; Sadasivam Sitaraman; Ramesh Choudhary; Kailash Kumar Meena; Ghan Shyam Bairwa; Mohan Bairwa; Amrit Jeevan
Journal:  Eur J Pediatr       Date:  2021-06-12       Impact factor: 3.183

5.  Large scale validation of a new non-invasive and non-contact bilirubinometer in neonates with risk factors.

Authors:  Animesh Halder; Aniruddha Adhikari; Ria Ghosh; Soumendra Singh; Amrita Banerjee; Nilanjana Ghosh; Arnab Madhab Bhattacharya; Shrabani Mandal; Prantar Chakrabarti; Debasis Bhattacharyya; Hatem M Altass; Moataz Morad; Saleh A Ahmed; Asim Kumar Mallick; Samir Kumar Pal
Journal:  Sci Rep       Date:  2020-07-07       Impact factor: 4.379

6.  Should transcutaneous bilirubin be measured in preterm infants receiving phototherapy? The relationship between transcutaneous and total serum bilirubin in preterm infants with and without phototherapy.

Authors:  Christian V Hulzebos; Deirdre E Vader-van Imhoff; Arend F Bos; Peter H Dijk
Journal:  PLoS One       Date:  2019-06-14       Impact factor: 3.240

7.  Transcutaneous Bilirubin Measurements Can Be Used to Measure Bilirubin Levels during Phototherapy.

Authors:  Saad Abdullah Alsaedi
Journal:  Int J Pediatr       Date:  2018-03-20

8.  Transcutaneous bilirubin estimation in extremely low birth weight infants receiving phototherapy: a prospective observational study.

Authors:  Vidit Bhargava; Daniel Tawfik; Bruce Niebuhr; Sunil K Jain
Journal:  BMC Pediatr       Date:  2018-07-10       Impact factor: 2.125

  8 in total