Literature DB >> 21815388

Population dose from medical exposure in Taiwan for 2008.

T R Chen1, Y S Tyan, P S Teng, J H Chou, C Y Yeh, C H Shao, C J Tung.   

Abstract

PURPOSE: The largest contribution to the population dose from man-made ionizing radiation sources is the medical exposure. Exposure to patients from medical examinations is of interest because it is a global indicator for the quality of radiology practice. Due to the different healthcare systems and the considerable variations in the equipment and manpower in radiology, the population dose from medical exposure varies by a large extent in different countries. This dose from different diagnostic procedures provides information that can be used to establish national reference levels. It is also useful to determine the priority in terms of dose reduction so as to optimize the protection of patients in a cost-effective manner. In the present work, the collective effective doses due to different medical modalities were estimated for the Taiwan population in 2008.
METHODS: The collective effective dose from medical exposure was calculated using information on the number of procedures and the average effective dose per procedure. The frequency of procedures was extracted from the National Health Insurance (NHI) research database. The enrollment of Taiwan population in the NHI program was 99.48% in 2008. The average effective dose per procedure was derived from hospital surveys, measured data, and published results.
RESULTS: Estimates of the collective effective dose were made for different medical modalities, i.e., the conventional radiography and fluoroscopy, computed tomography, interventional fluoroscopy, nuclear medicine, and dental radiography. Each modality was further divided into relevant classes by the body part or organ system. Among 23 037 031 Taiwan population in 2008, the annual examination frequencies per 1000 population were 550, 55.1, 15.6, 13.6, and 112 for the conventional radiography and fluoroscopy, computed tomography, interventional fluoroscopy, nuclear medicine, and dental radiography, respectively. The corresponding collective effective doses were 3277, 8608, 2743, 2303, and 28 man-Sv, respectively. Thus, the average effective dose per caput was 0.74 mSv, which was in the range of 0.3-1.5 mSv for the 12 European countries estimated for 2008.
CONCLUSIONS: In the period from 1997 to 2008, the procedure frequency per 1000 population increased by a factor of 2.3 for computed tomography, 2.2 for interventional fluoroscopy, 1.8 for conventional radiography and fluoroscopy, and 1.5 for nuclear medicine. It demonstrated that the medical utilization of imaging facilities raised rapidly.

Entities:  

Mesh:

Year:  2011        PMID: 21815388     DOI: 10.1118/1.3592936

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  The Incremental Diagnostic Performance of Coronary Computed Tomography Angiography Added to Myocardial Perfusion Imaging in Patients with Intermediate-to-High Cardiovascular Risk.

Authors:  Pei-Ying Hsu; Wen-Jeng Lee; Mei-Fang Cheng; Ruoh-Fang Yen; Kai-Yuan Tzen; Yen-Wen Wu
Journal:  Acta Cardiol Sin       Date:  2016-03       Impact factor: 2.672

2.  Effective dose assessment for participants in the National Lung Screening Trial undergoing posteroanterior chest radiographic examinations.

Authors:  Randell Kruger; Michael J Flynn; Phillip F Judy; Christopher H Cagnon; J Anthony Seibert
Journal:  AJR Am J Roentgenol       Date:  2013-07       Impact factor: 3.959

3.  The Population Effective Dose of Medical Computed Tomography Examinations in Taiwan for 2013.

Authors:  Da-Ming Yeh; Hui-Yu Tsai; Yen-Sheng Tyan; Yu-Cheng Chang; Lung-Kwang Pan; Tou-Rong Chen
Journal:  PLoS One       Date:  2016-10-27       Impact factor: 3.240

4.  The risk of cataractogenesis after gamma knife radiosurgery: a nationwide population based case-control study.

Authors:  Cheng-Loong Liang; Po-Chou Liliang; Tai-Been Chen; Huan-Chen Hsu; Fu-Cheng Chuang; Kuo-Wei Wang; Hao-Kuang Wang; San-Nan Yang; Han-Jung Chen
Journal:  BMC Ophthalmol       Date:  2017-04-04       Impact factor: 2.209

5.  Radiation doses with various body weights of phantoms in brain 128-slice MDCT examination.

Authors:  Hung-Chih Lin; Te-Jen Lai; Hsien-Chun Tseng; Ching-Hsiang Wang; Yen-Ling Tseng; Chien-Yi Chen
Journal:  J Radiat Res       Date:  2019-07-01       Impact factor: 2.724

Review 6.  Radiation exposure by medical X-ray applications.

Authors:  Barbara Buchberger; Katharina Scholl; Laura Krabbe; Ljuba Spiller; Beate Lux
Journal:  Ger Med Sci       Date:  2022-03-31
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.