Abstract
BACKGROUND: Mass spectrometry-based metabolomics analyses have the potential to complement sequence-based methods of genome annotation, but only if raw mass spectral data can be linked to specific metabolic pathways. In untargeted metabolomics, the measured mass of a detected compound is used to define the location of the compound in chemical space, but uncertainties in mass measurements lead to "degeneracies" in chemical space since multiple chemical formulae correspond to the same measured mass. We compare two methods to eliminate these degeneracies. One method relies on natural isotopic abundances, and the other relies on the use of stable-isotope labeling (SIL) to directly determine C and N atom counts. Both depend on combinatorial explorations of the "chemical space" comprised of all possible chemical formulae comprised of biologically relevant chemical elements.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21810208 PMCID: PMC3223729 DOI: 10.1186/1471-2164-12-S1-S6
Source DB: PubMed Journal: BMC Genomics ISSN: 1471-2164 Impact factor: 3.969
Figure 1Numbers of metabolites (red bars) and chemical formulae (black bars) in the MetaCyc database present only in a specific number of reactions (A) or pathways (B). Numbers of metabolites (red bars) and chemical formulae (black bars) in the KEGG database present only in a specific number of reactions (C). Metabolites present in reactions not linked to any pathway in MetaCyc were not taken into account for panel B. A large number of metabolites and chemical formulae are unique, thus are associated with a single reaction or pathway.
Figure 2Schematic illustrating conceptual and experimental approaches to representing and searching through chemical space. As shown in (A), the monoisotopic mass of folate (M0) is projected into the range of possible chemical species in chemical space. Many distinct points in chemical space are nearly indistinguishable in this projection (“degeneracy”). In (B), the points are projected into 3 dimensional space where the number of nitrogen and carbon atoms in each chemical formula is known, and in (C), the isotopic intensities of M1 and M2 peaks relative to the M0 peak form other axes along which formulae can be projected.
Figure 3Comparison of formula generation algorithms. The HR2 algorithm (A) or the Brute Force algorithm (B) was used to estimate the mass degeneracy (to within 5 ppm mass accuracy) of representative points in chemical space, i.e., the number of unique chemical formulae within 5 ppm of a target mass. Brute force consistently found a higher mass degeneracy in chemical space (i.e., more possible formulae) than HR2. Additionally, for approximately 5% of the representative points chosen, HR2 (C) was unable to find any point in chemical space (i.e. recapitulate the formula corresponding exactly to the seed mass).
Figure 4Stable isotope labeling restricts the number of possible chemical formulae for measured mass values in metabolomics datasets. All panels show a distribution of chemically representative unique masses in chemical space. In panel (A) HR2 was used to calculate the proportion of these unique masses having either no mass degeneracy (black) within (at 5 ppm), masses having a single mass degeneracy (blue), or two or more mass degeneracies (red). Panels (B) and (C) show how specifying points in chemical space by not only the exact mass, but also C atom counts and N atom counts as determined by stable isotopic labeling, affects the degeneracy. Panel (B) uses HR2 to estimate the degeneracy, while in (C) Brute Force is used.
Figure 5Comparison of stable isotope labeling to relative isotopic peak intensity as a means of aiding unique formula determination. Panels (A) & (C) show the fraction of tests where the specification of the chemical formulae using the C and N count was improved in comparison to using only relative isotopic peak intensity. Panels (B) & (D) show the mass distribution of tests where each method performed better or worse. Brute force was used in panels (A) and (B). HR2 was used in panels (C) and (D). These plots show that for larger compounds the C and N atom count provides information not obtainable from relative isotopic peak intensity.