Literature DB >> 21805569

Bench top evaluation and clinical experience with the Szabo technique: new questions for a complex lesion.

Beatriz Vaquerizo1, Antonio Serra, John Ormiston, Faustino Miranda-Guardiola, Bruce Webber, Andres Fantuzzi, Guillermo Delgado, Jordi Brugera.   

Abstract

BACKGROUND: The Szabo technique has been described as a method to ensure accurate ostial stent placement. We sought to investigate this novel technique in detail both in vitro and in vivo. METHODS AND
RESULTS: The technique was subjected to bench testing and also undertaken in 26 patients. Each step was recorded with cine angiography and the stents imaged by microcomputed tomography. The ostial LAD was treated in 81% and a DES was implanted in 92%. Angiographic success was 88.5% (one case of stent dislodgement). Repeat angiography was performed in 78% and restenosis observed in two patients. MACE rate at 15.5 ± 5.1 months was 13% (1 TLR, 1 MI, 1 cardiac death). Despite a seemingly excellent immediate angiographic result, we report one case of restenosis at follow up and one case of IVUS examination (performed in four patients) in which significant stent protrusion, into the proximal main vessel, was observed. In vitro bench testing confirmed a significant and asymmetric (carina side) stent protrusion into the main branch, with the last cell of the stent undergoing significant deformation.
CONCLUSIONS: The Szabo technique is not a precise technique to implant a stent at the level of the ostium. The proximal end of the stent undergoes significant and asymmetric deformation, protruding into main branch. Additional concerns with this complex technique include the potential for stent damage or contamination before implantation and the risk of stent dislodgement. We conclude that there are more disadvantages than benefits to this technique which only partially addresses the difficulties encountered in the treating ostial lesions.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21805569     DOI: 10.1002/ccd.23087

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  4 in total

1.  Comparison of floating wire and single wire techniques in right coronary ostial lesions in terms of procedural features and one-year clinical follow-up results.

Authors:  Ahmet Taştan; Erdem Özel; Ali Öztürk; Samet Uyar; Emin Evren Özcan; Ömer Şenarslan; Talat Tavlı
Journal:  Anatol J Cardiol       Date:  2014-10-31       Impact factor: 1.596

2.  The Use of Bumper Wire Technique and Intravascular Ultrasound for Precise Aorto-Ostial Stenting.

Authors:  Pavan K V Reddy; Joseph Daibes; Michel Skaf; Roberto Ochoa; Tomohiro Fujisaki; Patricia Lin; Apurva Patel; Tak Kwan
Journal:  Front Cardiovasc Med       Date:  2022-07-14

3.  Three-dimensional optical coherence tomography reconstruction of bifurcation stenting using the Szabo anchor-wire technique.

Authors:  Katherine Yu; Harkawal Hundal; Todd Zynda; Arnold Seto
Journal:  World J Cardiol       Date:  2017-04-26

4.  Potential value of guard-wire technology in the interventional treatment for ostial coronary lesions.

Authors:  Xiaoqiong Wang; Xuemei Zong; Bingqiang Li; Zhanying Han; Xinjie Duan; Ying Li; Jing Zhang; Yaohui Wang; Yaoli Wang
Journal:  BMC Cardiovasc Disord       Date:  2020-11-19       Impact factor: 2.298

  4 in total